Literature DB >> 32049646

Recommendation for performance verification of patient-based real-time quality control.

Tze Ping Loh1, Andreas Bietenbeck2, Mark A Cervinski3,4, Huub H van Rossum5,6, Alex Katayev7, Tony Badrick8.   

Abstract

Patient-based real-time quality control (PBRTQC) is a laboratory tool for monitoring the performance of the testing process. It includes well-established procedures like Bull's algorithm, average of nomals, moving median, moving average (MA) and exponentially (weighted) MAs. Following the setup and optimization processes, a key step prior to the routine implementation of PBRTQC is the verification and documentation of the performance of the PBRTQC as part of the laboratory quality system. This verification process should provide a realistic representation of the performance of the PBRTQC in the environment it is being implemented in, to allow proper risk assessment by laboratory practitioners. This document focuses on the recommendation on performance verification of PBRTQC prior to implementation.

Entities:  

Keywords:  evaluation; moving average; moving median; patient-based quality control; patient-based real-time quality control; verification

Year:  2020        PMID: 32049646     DOI: 10.1515/cclm-2019-1024

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  6 in total

1.  An Objective Approach to Deriving the Clinical Performance of Autoverification Limits.

Authors:  Tze Ping Loh; Rui Zhen Tan; Chun Yee Lim; Corey Markus
Journal:  Ann Lab Med       Date:  2022-09-01       Impact factor: 4.941

2.  Impact of combining data from multiple instruments on performance of patient-based real-time quality control.

Authors:  Qianqian Zhou; Tze Ping Loh; Tony Badrick; Chun Yee Lim
Journal:  Biochem Med (Zagreb)       Date:  2021-04-15       Impact factor: 2.313

3.  A study of the moving rate of positive results for use in a patient-based real-time quality control program on a procalcitonin point-of-care testing analyzer.

Authors:  Yili He; Daqing Gu; Xiangzhi Kong; Zhiqiang Feng; Weishang Lin; Yunfeng Cai
Journal:  J Clin Lab Anal       Date:  2022-03-07       Impact factor: 2.352

4.  Assessment of patient based real-time quality control on comparative assays for common clinical analytes.

Authors:  Yide Lu; Fan Yang; Dongmei Wen; Kaifeng Shi; Zhichao Gu; Qiuya Lu; Xuefeng Wang; Danfeng Dong
Journal:  J Clin Lab Anal       Date:  2022-08-10       Impact factor: 3.124

5.  Moving average procedures as an additional tool for real-time analytical quality control: challenges and opportunities of implementation in small-volume medical laboratories.

Authors:  Vera Lukić; Svetlana Ignjatović
Journal:  Biochem Med (Zagreb)       Date:  2021-12-15       Impact factor: 2.313

6.  Comparison and optimization of various moving patient-based real-time quality control procedures for serum sodium.

Authors:  Yuanyuan Li; Qian Yu; Xiaoyan Zhang; Xiaoling Chen
Journal:  J Clin Lab Anal       Date:  2021-09-14       Impact factor: 2.352

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.