Literature DB >> 32039957

Anchorless Arthroscopic Transosseous and Anchored Arthroscopic Transosseous Equivalent Rotator Cuff Repair Show No Differences in Structural Integrity or Patient-reported Outcomes in a Matched Cohort.

Uma Srikumaran1, Eric G Huish1, Brendan Y Shi1, Casey V Hannan1, Iman Ali1, Kelly G Kilcoyne1.   

Abstract

BACKGROUND: Anchored transosseous equivalent suture-bridge technique (TOE) is widely used for arthroscopic rotator cuff repair. It is unknown how patient outcomes scores, ROM, and integrity of the rotator cuff after repair using this anchored technique compare with those after repair using an anchorless transosseous technique (TO). QUESTIONS/PURPOSES: (1) What are the differences in patient-reported outcomes (American Shoulder and Elbow Surgeons [ASES] score) and shoulder ROM between TO and TOE rotator cuff repair techniques at 1 and 2 years after surgery? (2) What is the difference in repair integrity as measured by the re-tear rate, assessed ultrasonographically at 1 year, between these two techniques? (3) What is the difference in procedure duration between the two techniques when performed by a surgeon familiar with each?
METHODS: We reviewed 331 arthroscopic rotator cuff repairs performed by one surgeon from December 2011 to July 2016 in this retrospective, matched-pair study. Of these patients, 63% (208 of 331) underwent repair with standard anchored technique (anchors placed in a double-row, TOE manner) and 37% (123 of 331) underwent anchorless TO repair, with the same indications for surgery between groups. Forty-four percent (91 of 208) of patients in the TOE group and 61% (75 of 123) of patients in the TO group met the inclusion criteria. Eighty percent (73 of 91) of patients in the TOE group and 88% (66 of 75) in the TO group had minimum 2-year follow-up. We matched each group to a cohort of 50 patients by sex, age, smoking status, and tear size (by Cofield classification: small, < 1 cm; medium, 1-3 cm; large, > 3-5 cm; or massive, > 5 cm). The resulting cohorts did not differ in mean age (TO, 62 years [range 53-65 years]; TOE, 58 years [range 53-65 years]; p = 0.79), mean BMI value (TO, 30 [range 27-33]; TOE, 29 [range 27-35]; p = 0.97), or dominant arm involvement (TO, 80%; TOE, 78%; p = 0.81). The cohorts were followed for at least 2 years (median, 3.2 years [interquartile range (IQR) 2.2-4.3] for TO and 2.9 years [IQR 2.0-3.5 years] for TOE). ASES scores and ROM were evaluated before surgery and at follow-up visits and were recorded in a longitudinally maintained institutional database. Repair integrity was assessed using ultrasonography at 1 year, as is standard in our practice. For each tear-size group, we calculated the proportion of intact tendon repairs versus the proportion of re-tears. Duration of surgery was recorded for each patient.
RESULTS: At 1 year, we observed no difference in median ASES scores (90 [IQR 92-98] for TO and 88 [IQR 72-98] for TOE; p = 0.44); external rotation (50° [IQR 45°-60°) for TO and 50° [IQR: 40°-60°] for TOE; p = 0.58); forward flexion (165° [IQR 160°-170°] for both groups; p = 0.91); or abduction (100° [IQR 90°-100°] for TO and 90° [IQR 90°-100°] for TOE; p = 0.06). Fourteen percent of shoulders (seven of 50) in each treatment group had evidence of re-tear at 1 year (p > 0.99): 0 of 2 small tears in each group, 0 of 7 medium tears in each group, five of 32 large tears in each group, and two of 9 massive tears in each group (all, p > 0.99). At 2 years, we found no differences in median ASES scores (92 [IQR 74-98)] for TO and 90 [IQR 80-100] for TOE; p = 0.84); external rotation (60° [IQR 50°-60°] for both groups; p = 0.74); forward flexion (170° [IQR 160°-170°] for both groups; p = 0.69); or abduction (100° [IQR 90°-100°] for both groups; p = 0.95). We found no differences between groups in mean ± SD procedure time, which was 103 ± 20 minutes for TO repair and 99 ± 20 minutes for TOE repair (p = 0.45).
CONCLUSIONS: TO and TOE techniques for arthroscopic rotator cuff repair results in no differences in ROM, ASES scores, re-tear rates, and surgical time. Randomized control trials are needed to confirm these similarities or determine a superior method of repair. Future cost analyses may also help to determine the relative value of each technique. LEVEL OF EVIDENCE: Level III, therapeutic study.

Entities:  

Mesh:

Year:  2020        PMID: 32039957      PMCID: PMC7319398          DOI: 10.1097/CORR.0000000000001151

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.755


  34 in total

1.  Rotator cuff tears: the effect of the reconstruction method on three-dimensional repair site area.

Authors:  Maria Apreleva; Mehmet Ozbaydar; Peter G Fitzgibbons; Jon J P Warner
Journal:  Arthroscopy       Date:  2002 May-Jun       Impact factor: 4.772

2.  Initial fixation strength of transosseous-equivalent suture bridge rotator cuff repair is comparable with transosseous repair.

Authors:  Steve B Behrens; Benjamin Bruce; Alan J Zonno; David Paller; Andrew Green
Journal:  Am J Sports Med       Date:  2011-11-16       Impact factor: 6.202

3.  The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique.

Authors:  Laurent Lafosse; Roman Brozska; Bruno Toussaint; Reuben Gobezie
Journal:  J Bone Joint Surg Am       Date:  2007-07       Impact factor: 5.284

Review 4.  Arthroscopic rotator cuff repairs: an anatomic and biomechanical rationale for different suture-anchor repair configurations.

Authors:  Brian J Cole; Neal S ElAttrache; Ammar Anbari
Journal:  Arthroscopy       Date:  2007-06       Impact factor: 4.772

Review 5.  Which method of rotator cuff repair leads to the highest rate of structural healing? A systematic review.

Authors:  Thomas R Duquin; Cathy Buyea; Leslie J Bisson
Journal:  Am J Sports Med       Date:  2010-04       Impact factor: 6.202

6.  Anchored Transosseous-Equivalent Versus Anchorless Transosseous Rotator Cuff Repair: A Biomechanical Analysis in a Cadaveric Model.

Authors:  Kelly G Kilcoyne; Stanley G Guillaume; Catherine V Hannan; Evan R Langdale; Stephen M Belkoff; Uma Srikumaran
Journal:  Am J Sports Med       Date:  2017-05-18       Impact factor: 6.202

7.  Suture number determines strength of rotator cuff repair.

Authors:  Patrick W Jost; M Michael Khair; Dan X Chen; Timothy M Wright; Anne M Kelly; Scott A Rodeo
Journal:  J Bone Joint Surg Am       Date:  2012-07-18       Impact factor: 5.284

8.  Arthroscopic Transosseous and Transosseous-Equivalent Rotator Cuff Repair: An Analysis of Cost, Operative Time, and Clinical Outcomes.

Authors:  Adam J Seidl; Nicholas J Lombardi; Mark D Lazarus; Eric M Black; Mitchell G Maltenfort; Matthew D Pepe; Luke S Austin
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2016 Nov/Dec

9.  Repair integrity and functional outcome after arthroscopic double-row rotator cuff repair. A prospective outcome study.

Authors:  Hiroyuki Sugaya; Kazuhiko Maeda; Keisuke Matsuki; Joji Moriishi
Journal:  J Bone Joint Surg Am       Date:  2007-05       Impact factor: 5.284

10.  Midterm clinical outcomes following arthroscopic transosseous rotator cuff repair.

Authors:  Brody A Flanagin; Raffaele Garofalo; Eddie Y Lo; LeeAnne Feher; Alessandro Castagna; Huanying Qin; Sumant G Krishnan
Journal:  Int J Shoulder Surg       Date:  2016 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.