Composite lightweight materials for X-ray shielding applications were studied anddeveloped with the goal of replacing traditional screens made of lead and steel, with innovativematerials with similar shielding properties, but lighter, more easily formed and workable, with lowerimpact on the environment and reduced toxicity for human health. New epoxy-based compositesadditivated with barium sulfate and bismuth oxide were designed through simulations performedwith software based on Geant4. Then, they were prepared and characterized using differenttechniques starting from digital radiography in order to test the radiopacity of the composites,in comparison with traditional materials. The lower environmental impact and toxicity of theseinnovative screens were quantified by Life Cycle Assessment (LCA) calculation based on the ecoinventdatabase, within the openLCA framework. Optimized mixtures are (i) 20% epoxy/60% bismuthoxide/20% barite, which guarantees the best performance in X-ray shielding, largely overcomingsteel, but higher in costs and a weight reduction of circa 60%; (ii) 20% epoxy/40% bismuth oxide/40%barite which has slightly lower performances in shielding, but it is lighter and cheaper than thefirst one and (iii) the 20% epoxy/20% bismuth oxide/60% barite which is the cheapest material, stillmaintaining the X-ray shielding of steel. Depending on the cost/efficiency request of the specificapplication (industrial ra.
Composite lightweight materials for X-ray shielding applications were studied anddeveloped with the goal of replacing traditional screens made of lead and steel, with innovativematerials with similar shielding properties, but lighter, more easily formed and workable, with lowerimpact on the environment and reduced toxicity for human health. New epoxy-based compositesadditivated with barium sulfate and bismuth oxide were designed through simulations performedwith software based on Geant4. Then, they were prepared and characterized using differenttechniques starting from digital radiography in order to test the radiopacity of the composites,in comparison with traditional materials. The lower environmental impact and toxicity of theseinnovative screens were quantified by Life Cycle Assessment (LCA) calculation based on the ecoinventdatabase, within the openLCA framework. Optimized mixtures are (i) 20% epoxy/60% bismuthoxide/20% barite, which guarantees the best performance in X-ray shielding, largely overcomingsteel, but higher in costs and a weight reduction of circa 60%; (ii) 20% epoxy/40% bismuth oxide/40%barite which has slightly lower performances in shielding, but it is lighter and cheaper than thefirst one and (iii) the 20% epoxy/20% bismuth oxide/60% barite which is the cheapest material, stillmaintaining the X-ray shielding of steel. Depending on the cost/efficiency request of the specificapplication (industrial ra.
X-ray shielding is particularly interesting for many applications, from the industrial field of non destructive control techniques (radiography and tomography), airport scanners and control [1] to the medical field (radiology and dentistry) [2,3]. Nowadays the most common shields for X-rays are still made of lead and steel. While lead has excellent shielding properties, its mechanical features are very poor, being very soft and malleable. Steel, instead, has sufficient shielding properties and excellent mechanical performances but high costs and limited workability for the realization of shielding masks by machining. These materials have complementary advantages in the quality of the shielding, soft X-rays cutting and good mechanical properties, but the drawbacks are objects weight, human health hazards and environment pollution. The principal solutions given in the specialized literature are based on three different types of materials: inorganic, organic and composites. The most common alternative to the traditional shielding is the use of inorganic materials: a compressed slab of minerals like barium sulfate (BaSO4), calcium sulfate (CaSO4) or calcium carbonate (CaCO3). This kind of solution is easy to obtain but the objects have very poor mechanical properties, with low tensile strength and tendency to crumble. Furthermore, the weight gain is not so convenient. The second solution is represented by organic materials in which the number of electrons by volume unit is increased by adding iodine atoms to polymeric chains: mostly, isoprenic rubber is synthesized with monomers that have iodine atoms covalently bound. Examples of these monomers are iopanoic acid 3-(3-amino-2,4,6-triiodophenyl)-2-ethyl propanoic acid and iothalamic acid (5-acetamido-2,4,6-triiodo-N-methyl iso-phthalamic acid) and 2,4,6-triiodobenzoic acid [4,5,6]. Resulting materials have sufficient radiopacity and good mechanical performances. Also, as the iodine is covalently bound, the chances of leaks are low. However, these kinds of shields are unfit for industrial radiography, where the photon energies are larger than 150 keV. In this region, because of the dilution of iodine into the polymer, the shielding power is very low. The last class is that of composite materials, attempting at joining the qualities of minerals (high shielding and no or low toxicity) with those of metals (good mechanical properties), adding an improved workability and lower cost. Composites are divided in two sub-classes:metal powders embedded in the polymeric matrices. Some of these solutions are already in commerce, e.g., tungsten-loaded polylactic acid for 3D-Printing [7];minerals included in polymeric matrices, typically high density oxides such as zinc oxide (ZnO), tin oxide (SnO2) or bismuth oxide (Bi2O3) [2,8,9,10] and compounds of materials of the sixth period of the periodic table such as barium sulphate (BaSO4) [11].A critical factor for composite materials is dispersion and adhesion of the solid materials to the polymer, in order to avoid both fractures and leakage of heavy transition/post-transition metals. Another critical issue resides in the homogeneous distribution of the additive in the whole volume of the sample, as evidenced by Prolongo et al. [12]. The sedimentation of the powder on the bottom side of the sample, may bring to three effects:reduction of the effective thickness of the shielding material, which causes the reduction of the overall shielding performance;different mechanical properties in the same sample based only on which side is considered, a chance that could bring to fracture or lower the overall resistance;anisotropic shielding yields.In this paper, we focus on developing low-cost lightweight shielding composite materials that can be easily processed, formed in complex shapes and produced. Materials from scientific literature were simulated with Geant4 to test their screening performances. Commercial epoxidic resins were chosen because of their low cost, easy formability and workability. Barium sulphate and bismuth oxide were chosen because of their good balance of low cost, radiopacity, low environmental impact and absent or low toxicity. Different composite formulations were then predicted with a Simplex-lattice experimental design and developed in laboratory. Materials were fully characterized using XRPD, optic and electronic microscopy, computed radiography and tensile strength test. The overall environmental impacts of the samples were examined through an LCA study “from the cradle to the gate” and compared to the same calculations for the traditional screens of lead and steel. It was thus possible to develop composite formulations able to assure the best performances in term of shielding, weight and low cost depending on final user requests.
2. Results
2.1. Geant4 Simulations
The first batch of simulations was made with a software based on Geant4 which simulates the interaction between electromagnetic radiation and matter; the interaction of pure materials selected from the scientific literature with monochromatic beams of X-rays was then studied adopting successive steps of energy in the range 0–350 keV, as described in Appendix B. This approach can be defined a “soft simulation” because of its approximation, since in industrial radiography the incident beam is a spectrum, more specifically the Bremsstrahlung spectrum plus the characteristic emissions of the anti cathode of the X-ray tube. The aim is estimating which materials were the best fitted for shields that have to be not only radiopaque, but also economically affordable and mechanically resistant. As showed in Figure 1a, the three principal additives from scientific literature, BaSO4, Bi2O3 and ZnO, over-perform the stainless steel in the range 75–240 keV, which is also the main energy of photons of standard X-ray tubes for radiography. Also, simulated samples of composites epoxy resin—BaSO4 were compared to steel in order to evaluate the effect that would be obtained by adding this inorganic additive into the epoxy resin (Figure 1b). After this analysis, ZnO was discarded because its shielding properties are similar to those of barium sulfate, but its cost is about 100 times higher. Samples predicted from the Simplex-lattice experimental design for a ternary mixture were simulated in a second time with a second application built with Geant4, which allowed a more accurate approach to the problem. This new simulation setup featured a thin tungsten solid between the beam source and the sample. Incident particles were also changed from X-rays to electrons, so that from the first impact with the anti cathode, a characteristic Bremsstrahlung spectrum of X-rays of W would be generated and focused on the sample, as described in Figure A1 in Appendix B. Figure 2a–d show the simulated behavior of each sample compared to steel. In the range of 30 keV–80 keV some spikes are evident, and are the characteristic emissions of the tungsten target (K keV, K keV) or effects of absorption-emission from the heavy atoms in the screens ( Barium keV, Barium K keV, Bismuth K keV, Bismuth K keV). Results of this simulation set can be seen in Figure 2. The large noise in the simulation results is due to the high rate in absorption from the material; on the other hand, a fit of the resulting data would lead to a loss of information about the K and K riemissions from the heavy metals in the simulated samples. Studied samples all perform better than steel, in particular sample of Figure 2d.
Figure 1
First generation of simulations. These data are referred to 1 cm cubes irradiated with a monochromatic beam of X-rays at successive steps of photon energies, from 0 to 350 keV. In (a) common shielding materials from scientific literature are compared. In (b) samples of mixture between epoxy resin and BaSO4 are simulated and compared to stainless steel. (a) Pure materials; (b) BaSO4 samples.
Figure A1
Simulation of shielding properties of the materials. Electrons are generated from one side of the envelope and travel through the space filled with vacuum via ”” material. Electrons hit the tungsten target, which generates characteristic X-ray emission. This spectrum (the Bremsstrahlung spectrum of W) is focused on the sample, in order to evaluate its radiopacity by measuring the number of the transmitted X-rays.
Figure 2
Simulations of the transmitted spectrum of Bremsstrahlung of a tungsten target of 300 μm through a sample of a 1 cm-sided cube of different mixtures compared to the same solid of stainless steel. (a) shows the transmitted spectrum through a sample of pure epoxy resin with no additive; the log scale was set due to the high rate of transmitted photons that crossed the polymeric materials. (a) Pure epoxy resin; (b) 60% BaSO4, 20% Bi2O3, 20% Epoxy; (c) 40% BaSO4, 40% Bi2O3, 20% Epoxy; (d) 20% BaSO4, 60% Bi2O3, 20% Epoxy.
2.2. Setup and Optimization of Sample Preparation Methods
The inorganic additives were analyzed with X-ray Powder Diffraction to evaluate the purity of the minerals before being added to the polymeric matrix. The XRPD patterns of barium sulfate by Itaprochim and Universal Services S.r.l. and of bismuth oxide by Thermo Fischer (Kandel, Germany) were collected. After identifying the impurities by peak matching using QualX [13], Rietveld refinement was performed on the XRPD patterns using structures from the Crystallographic Information Files retrieved from the Crystallographic Open Database and TOPAS Academic V5 [14]. Identified in the first barium sulfate batch (Itaprochim) some impurities: calcite (CaCO3), and dolomite (CaMg(CO3)2) and respectively. Blanc fixe barium sulfate (Universal Services S.r.l.) and Bi2O3 showed a purity of and no relevant impurities were found by XRPD analysis.Nine samples (Table 1) were produced with epoxy resin and an increasing mass fraction of BaSO4 (Itaprochim), from to according to the procedure described in Section 5 and shown in Appendix C; was observed to be the upper limit of wettability of the powders and, consequently, the limit of mixability between powders and liquid precursors of the epoxy resin. XRPD was also used to characterize this same batch of nine barite samples. After their curing, they were analyzed on both sides: the one exposed to the air and the one in contact with the mold. The samples showed different behaviors depending on the sides and the quantity of inorganic additive.
Table 1
Samples of BaSO4—Epoxy composites to assess additive amount effect.
BaSO4 Samples
Sample Name
BaSO4 Weight %
Epoxy Weight %
1
0
100
2
30
70
3
40
60
4
50
50
5
60
40
6
70
30
7
80
20
8
80
20
9
85
15
In Figure 3, bottom graph, in sample 2 the broad band of the amorphous epoxypolymer is evident, suggesting that most of the inorganic moved down in the sample during the curing. On the bottom side of the sample (Mold in Figure 3), the barium sulfate pattern is dominant, confirming the sedimentation of the additive. Rietveld refinement of all datasets indicated a different behaviour of barite and of dolomite impurities. Because of their different density and size, up to sample 5 the sedimentation of barite is larger with an increasing amount in the mold side with respect to dolomite. Conversely in samples 6, 7 and 8 this behavior is not observed and the trend is inverted with a smaller barite percentage in the mold side. This trend can be explained because samples 6, 7 and 8 were already rather viscous before curing and therefore the sedimentation effect was limited (Figure 4). In samples 7 and 8 the amorphous band is not visible and the intensity of air side and mold side patterns are very similar. The refined peak shift confirms the sedimentation hypothesis. A peak shift is observed but it is a combination of the sedimentation and of sample imperfections (bubbles and rugosity), causing a misalignment of the sample. XRPD evidenced a progressive sedimentation process, occurring during the time of gelification of the resin. The phenomenon is more evident in samples with an inorganic fraction smaller than , as the viscosity is low and the powders encounters little resistance to the deposition process.
Figure 3
XRPD patterns collected on both sides of sample 2 (30% w/w in BaSO4) and sample 7 (80% in BaSO4).
Figure 4
Quantitative analysis of crystalline phases of barite (BaSO4) and dolomite (CaMg(CO3)2) was done on air and mold sides of samples of epoxy/barite.
2.3. Experimental Design
Sample compositions were selected applying the Simplex-Lattice design algorithm described in Appendix A. The extension of the simplex, therefore the minimum amount of each component of the mixture, was decided considering the miscibility limit for the binary mixture BaSO4-epoxy, which was observed as , as discussed in Section 2.2. To avoid using the exact limits of the experimental domain the upper limit on the quantity of additive in the epoxy precursor was set to . Simplex-Lattice design described in Appendix A explores all the experimental domain, which in this case would not be useful due to the fact that the lone resin is completely transparent to X-rays and the other two vertexes of the simplex would lead to two slabs of pure compacted powder with no mechanical properties. Being the minimal content of epoxy resin equal to the of the total weight, the consequent simplex obtained is the one that can be seen in Figure 5. Then, applying Equation (A2) for three components and second grade interactions, the result obtained was:
Figure 5
Simplex-lattice design algorithm applied to a mixture for a 3-dimensional experimental domain. To each of the three component of the mixture domain a property was associated: low cost for barite, highest radiopacity for bismuth oxide and high mechanical performances for the epoxy resin. Black dotted samples were developed in laboratory, while red dotted samples were not due to an excessive radiotransparency to hard X-rays.
The result pinpoints the number of mixtures that had to be explored. Each sample of the simplex-lattice design was simulated with Geant4, but only the three black-dotted samples (a–c, in Table 2) had been prepared in laboratory. The three remaining samples: (d–f) provide low shielding from hard X-rays, but are still interesting for applications involving low energies (0–60 keV) and requiring good mechanical resistance to strain.
Table 2
Mixtures provided by Simplex-lattice design.
BaSO4–Bi2O3 Samples
Sample Name
BaSO4 Weight %
Bi2O3 Weight %
Epoxy Weight %
a
20
60
20
b
40
40
20
c
60
20
20
d
40
20
40
e
20
20
60
f
20
40
40
2.4. Direct Radiography
Figure 6 shows the radiographies collected over the nine first-generation samples, plus a reference made of steel, positioned on the bottom-right corner of the images. A graph of the performances of each sample compared to steel can be observed in Figure 6f. The curves were obtained by considering the gray scale values of the samples in the picture. The data were obtained by calculating the average gray scale value (from 0 to 255) over the whole sample area and then calculating the relative absorption. Curve 9, referred to the sample in weight of barite, overperforms steel in terms of radiation absorption, a property that can be appreciated also by eye in Figure 6e. This result apparently clashes with the results in Figure 1, which instead shows that at 220 keV steel should be a better screen than this mixture. The reason of these discrepancies resides once again in the structure of the first simulation, which involved a monochromatic source of X-rays, which is not the real-world case, in the radiographic system. Also, a generator on which is applied an electric potential of 220 kV, provides just few photons with energy of 220 keV; it has instead a maximum of the emission band at one third of the supplied tension (which gives about 70–75 keV, a range where the Epoxy-BaSO4 composite effectively performs better than steel). Another information that comes from these images resides in the high defectivity ratio that characterize the most additivated samples. These defects are mainly air bubbles that remain trapped in the highly viscous matrix. Voids represents points in the samples in which the optical path for the photons is shorter compared to the rest of the bulk. Also, this kind of defect lowers the resistance of the samples in terms of tensile strength. The second set of simulations with Geant4 suggested that the second generation of samples would be more radiopaque than the previous ones due to the presence of bismuth oxide, therefore the setup and the experimental conditions were changed increasing the flux and detector sensitivity. Therefore, a direct comparison between the two results could not be made. In Figure 2 it can be observed that all samples strongly overperform steel, which is fully transparent at 180 kV. In the same image, sample c shows a large amount of bubbles in the bulk. As foretold by the hard simulations, an increase of bismuth oxide corresponds to a higher screening performance of the shields (Figure 7).
Figure 6
Radiographies of epoxy-barite samples at increasing percentage w/w in BaSO4. Samples are labeled as in Table 2. Ref sample is the reference of steel. In (f), increasing X-ray absorbance profiles can be osberved, from left (0% w/w barite) to right (85% w/w barite). Greyscale data associated to (f) and relative statistics are available as supplementary material. (a) 20 kV; (b) 60 kV; (c) 100 kV; (d) 150 kV; (e) 220 kV; (f) Profile comparison.
Figure 7
Radiographies on the three ternary mixtures (samples a, b, c in Table 2) developed in laboratory compared with the same steel sample for reference. In this case the photon flux was raised by increasing the current intensity to explore the behavior of the screens in a more severe experimental condition. (a) 120 kV; (b) 180 kV; (c) 200 kV; (d) 220 kV.
2.5. Mechanical Characterization
To evaluate the mechanical performances of the composite samples, a study of stress/strain properties was done. Five dog bone shaped samples suitable for the tensile tests were obtained for each mixture of the second generation series of samples. Another five samples of pure epoxy resin were prepared and used as a reference. These samples were subject to traction until break point. Data reported in Table 3 refer to each mixture performances under stress. The pure epoxy resin, showed a plastic behavior, with plastic deformation before the break point. This was not observed for mixture samples, which showed fragile behavior and lower resistance if compared to the pure epoxy resin. The sections of the fracture point were observed with SEM (Figure 8), which showed, in additivated samples, micrometric domains of inorganic powder which are responsible for the fracture. The SEM images evidenced an increase of the size of bismuth oxide domains in the matrix proportional to the increase of its amount in the sample. This agglomeration (particle segregation) phenomenon is related to the large uncertainty on the strain resistance of the sample a. On the contrary, barium sulfate is finely dispersed in the sample, but having a lower density than bismuth oxide, the overall inorganic percentage by volume in sample c is higher than the percentage in the a sample. This explains well also the high uncertainty and the low strain resistance of this sample. Sample b has the best mechanical performances because of the low amount of bismuth oxide, whose big grains are the main initiators of the fractures, and an acceptable volume ratio of powders over the resin. In the same images bubbles, which developed during the polymerization and were not expelled from the matrix due to the high viscosity of the samples, can be observed.
Table 3
Each mixture was subject to tensile testing with five replicas for each sample. Pure epoxy resin samples were tested as a reference. The data show that epoxy resin would break in the range 26–305 MPa after plastic deformation. Samples a and c show a low tensile resistance, accompanied with a huge variation coefficient. Sample b has instead a good resistance and a low variation coefficient, suggesting a very good reproducibility.
Sample
Average Stress at Break Point
Standard Deviation
Variation Coefficient %
Epoxy resin
28.68 MPa
±1.98 MPa
6.91%
a
9.654 MPa
±5.34 MPa
55.30%
b
14.12 MPa
±1.19 MPa
8.46%
c
5.06 MPa
±1.62 MPa
31.99%
Figure 8
The four pictures show the sample section surface after the tensile test. The large Bi2O3 domains, visible in Figure 8d, are the main cause of fracture of the samples, while in Figure 8b, it can be seen that barium sulfate has a finer grain size. Figure 8c shows sample b, which has few large inorganic domains and a higher volumetric ratio of epoxy resin. (a) Epoxy resin; (b) Sample a; (c) Sample b; (d) Sample c.
2.6. LCA Study
A “from cradle to gate” LCA calculation was performed to assess the environmental performances of the produced epoxy-additive composites. Then, the results were compared with traditional screens made of lead and stainless steel. The LCA model was built using the openLCA software tool as described in Appendix D. The release 3.5 of the ecoinvent database was used as a reference for all the background data included in the LCA model. Foreground inventory data about raw materials, energy and processes, used for the making of the epoxy-additive samples, were taken directly from formulations while inventory data about the “from cradle to gate” life cycle of both screens of lead and stainless steel were taken from the literature. In this calculations a wide set of factors were considered and Life Cycle Impact Assessment results can be seen in Table 4. For reference, just sample b was compared to the traditional screens. This sample was selected among the three mixtures developed because of its intermediate screening properties, costs, environmental and human impact. Choosing just one of the three simplex samples does not heavily affects the following calculations, as the three epoxy samples were previously compared between them, and they showed little differences in the impacts. The variation of 20% in weight of Bi2O3 between the simplex samples does not affect the results heavily since the main reason due to the change in the impact relies in the relative scarcity of bismuth minerals and the consequent ore extraction. This process, compared to barium minerals, which instead are very common, is the main reason for the higher impact of bismuth on the calculation. Except for fossil resource scarcity, composite shielding materials are more sustainable than lead, and in terms of carcinogenicity they take a huge advantage over steel, as shown in Figure 9. In Table 4, impacts referring to the composite samples are generally lower than the ones referred to lead, except the parameters that depend on the quantity of the source ores (fossil resource scarcity, mineral resource scarcity...). Stainless steel impacts, compared to the composite ones are generally lower. However, humancarcinogenic toxicity of steel is strongly higher (two orders of magnitude) than that of the samples described in this work.
Table 4
LCA study results using the ReCipe 2016 method. The comparison was made among lead, steel and the average composite sample (b), since a comparison between the three developed mixtures would show very similar impacts.
Impact Category
Composite
Lead
Steel
Unit
Fine particulate matter formation
3.0083×10−3
1.7537×10−2
2.5890×10−3
kg PM2.5 eq
Fossil resource scarcity
7.6487×10−1
6.4664×10−1
4.1914×10−1
kg oil eq
Freshwater ecotoxicity
8.4606×10−2
9.1613×10−1
9.3025×10−2
kg 1,4-DCB
Freshwater eutrophication
6.1143×10−4
5.4034×10−3
6.4810×10−4
kg P eq
Global warming
2.0190
2.9701
1.4331
kg CO2 eq
Human carcinogenic toxicity
7.7873×10−2
3.8059×10−1
2.3177
kg 1,4-DCB
Human non-carcinogenic toxicity
2.3725
4.4880×101
1.6433
kg 1,4-DCB
Ionizing radiation
1.5145×10−1
1.0113×10−1
2.8174×10−1
kBq 60Co eq
Land use
1.9765×10−2
2.8625×10−2
7.5114×10−3
m2a crop eq
Marine ecotoxicity
1.0682×10−1
1.2924
1.3559×10−1
kg 1,4-DCB
Marine eutrophication
2.8346×10−4
1.2057×10−4
4.5165×10−5
kg N eq
Mineral resource scarcity
1.7336
5.0973×10−1
2.1350×10−3
kg Cu eq
Ozone formation, Human health
6.0554×10−3
1.6108×10−2
3.4478×10−3
kg NOx eq
Ozone formation, Terrestrial ecosystems
6.3136×10−3
1.6403×10−2
3.5129×10−3
kg NOx eq
Stratospheric ozone depletion
1.1278×10−6
2.8819×10−6
9.7955×10−7
kg CFC11 eq
Terrestrial acidification
7.1376×10−3
5.4225×10−2
8.7846×10−3
kg SO2 eq
Terrestrial ecotoxicity
7.2130
4.9729×101
1.0801×101
kg 1,4-DCB
Water consumption
3.5767×10−2
2.7976×10−2
2.6284×10−2
m3
Figure 9
The histogram is an extract from the previous table which shows the relative impacts for the main and most reliable factors showed in Table 4. Data were normalized to the maximum value for a rapid evaluation of the advantages and disadvantages of each material. Green bars refer to the impacts calculated for lead, red bars for the composite samples and blue bars are referred to steel impacts.
3. Discussion
This study identified mixtures of composite materials for X-ray shielding that have low toxicity for human health, low environmental impact as assessed by LCA analysis, low costs of production and processing and good mechanic resistance. Simulations through Geant4 of pure materials from scientific literature, showed in Figure 1b, allowed to identify the best performing materials in X-ray shielding. The chosen additives were bismuth oxide and barium sulfate. BaSO4 was chosen because it has similar performances in shielding to zinc oxide, but its cost is about 100 times lower. Nine BaSO4 - Epoxy composites in increasing weight percentage of additive were prepared and the simulations made with Geant4 were confirmed. Moreover, the upper limit of mixability between the resin and the inorganic additive was tested resulting in of additives. Bismuth, which showed excellent shielding properties in simulations, was selected to be mixed with barium sulphate to obtain high performances mixtures. The simplex-lattice experimental design for mixtures of Figure 5 was then developed, identifying each of the three components with a predominant factor (high screening properties, high stress resistance and low costs). Of the six resulting mixtures, only three were produced in laboratory, as the main requested property was the high x-ray absorption. The three others mixtures were not prepared because the observed transmission factors resulting from the simulations were too high for being integrated as industrial shielding materials. These samples can still be applied where the energies of produced X-rays are lower than 50 keV (such as the medical applications) and the strain resistance required has to be upper than 13–15 MPa.The three simplex mixtures were then analyzed through direct radiography and showed a screening effect trend in agreement with Geant4 prediction. Produced samples overperformed steel in terms of radiopacity with a much easier formability and workability and weight reduced up to the one third of a steel screen. It was thus possible to develop composite formulations depending in shielding performance, weight and costs requirements: mixture c is suitable as steel replacement. For systems that involve higher energies, mixtures a and b are the best choice. For other applications, like the medical ones, where energies involved are lower than 50 keV, the three remaining mixtures () are well suited. Looking to the molecular level, it was not possible obtaining direct indications about the interaction and the adhesion between the filler and the matrix. On one hand, the composites showed sufficient mechanical properties also at high loadings and this suggests that some polymer/additive interaction occurred. On the other hand, the aggregation of the additive suggest that it should be modified to improve its interaction with the epoxy matrix to improve the adhesion and thus optimizing both dispersion and mechanical properties. This can be done by improving the hydrophobicity of the additive surface by binding an organic molecule such as stearic acid or sodium dodecylsulfate. This approach will be studied and developed in a future work.
4. Conclusions
In this study, different formulation for easily formable composites lightweight shielding materials were proposed. The work explored the best performing mixtures between bismuth oxide, barium sulfate and epoxy resin, using a simplex-lattice experimental design for mixtures. The resulting mixtures (see Section 2.3 for details) can be used in different fields based on the requirements of shielding ratio, mechanical properties and lightness. For low photon-energy applications, such as the medical field, 20:20:60, 20:40:40 and 40:20:40 BaSO4/Bi3O3/epoxy resin mixtures are the best ones, due to their lightweight and good performances in shielding and mechanical resistance. For hard X-ray industrial applications, such as radiography and computed tomography with energies in the 20-220keV range, the best performing mixtures are: 60:20:20, 40:40:20 and 20:60:20 BaSO4/Bi3O3/epoxy resin . In details, three mixtures (labeled a–c) have performances higher than steel (mixture a has more shielding capability, mixture b has and mixture c has with a weight reduction ranging from to depending on which mixture is chosen), becoming good candidates for traditional screen replacement. Besides physical, chemical, morphological and mechanical characterization to demonstrate their suitability for real world usage, an LCA study was conducted to compare screens made of lead and steel with the produced mixtures. Results show that the produced samples have an overall environmental impact lower than those based on lead (Global warming less, fine particular matter formation less, human non-carcirogenic toxicity less,…) and a lower humancarcinogenic impact ( less) than those based on steel.
5. Materials and Methods
5.1. Materials and Preparation
All samples were prepared starting from technical grade reagents. A two-components epoxy resin was purchased by S.E. Special Engine S.r.l. (Torino, Italy). Component A (Sepox 225) of the epoxy was made up by of bisphenol-A-(epichlorhydrin) and epoxy resins with average molecular mass lower than 700 . Component B (DK 505) was of 3-aminomethyl-3 5 5-trimethylcyclohexylamine and between of polyoxypropylenediamine.Barite ( calcite, dolomite) was given by Itaprochim (Garlasco, Italy) and other two samples of Barite (Blanc Fixe JM3B and Blanc Fixe G) were given by Universal Services S.r.l. (Milano, Italy) and produced by Solvay (Massa, Italy), Bi2O3 (>99% ) and SnO2 (>99% ) was given by Todini (Monza, Italy) and Thermo Fischer (Kandel, Germany). Samples were prepared as described in Appendix C.
5.2. Analysis Methods
Powder materials were analyzed through XRPD and the diffraction patterns were compared with the ones simulated with the corresponding .cif files downloaded from the Crystallographic Open Database (COD) [15]. PXRD pattern were collected with a Thermo ARL XTRA48 X-ray diffractometer. Patterns were collected in the angle range from 15 to 65 degrees. X-ray tube’s electric potential was set to 45 kV and current intensity to 40 mA. Slits were set as a standard measurement 2 mm, 4 mm, 0.5 mm, 0.2 mm. Resolution was set to 0.02° and scan speed to 2.00°/min. Radiographic tests for sample of binary mixture BaSO4/Epoxy were performed by the direct digital radiography technique; an Yxlon Y.XMB X-ray module was used as X-ray source and a Carestream DRX-1 as detector (filament current: 10 mA; voltage: 20 kV–220 kV). In the case of simplex samples, the computed digital radiography technique was used with the same previous X-ray source and a GE CRxFlex IPS imaging plate as detector (current: 5 mA; voltage 20 mA–220 kV). Radiographies collected were processed with ImageJ to extract grey-scale values for confrontations. Sections 10 m in thickness were cut on a Leica RM 2125 RT rotary microtome; SEM images at different magnification were recorded on a Quanta 200 FEI Scanning Electron Microscope equipped with EDAX EDS attachment, using a tungsten filament as the electron source at 20 kV. All samples were coated with an Au layer of 20 nm to prevent surface charging.
5.3. Modeling
5.3.1. Geant4 Simulations
Simulations of radiopacity were performed (on a Sony Vaio laptop 4 GB RAM, 1.4 GHz i7 processor with Ubuntu 18.10) by Geant4. The simulations were performed in two steps: a first approach with monochromatic X radiation and a second one considering the generation of a Bremsstrahlung spectrum of tungsten as source for the sample irradiation, as described in Appendix B. (By using Geant4, a first screening of materials was conducted over the different solution found in the scientific literature. The simulation setup was designed by creating a 1 cm sided cube of material irradiated along the X-axis with a monochromatic beam of X-rays counting photons. The experiment was repeated at steps of 25 keV in the range of 0–350 keV so that the best performing materials could be selected).
5.3.2. openLCA Simulations
For this project the open source professional solution named openLCA 1.9 and the ecoinvent 3.5 database were used. openLCA by implementing powerful and flexible ways to model life cycle systems, with the ability to calculate environmental, social and economic indicators, with plugins which are providing different more specific elements, and with its open architecture which eases import and export of data and integration in other IT landscapes, is the free and open source software for modeling the life cycle of things [16]. The ecoinvent database is the world’s leading LCI database which delivers both in terms of transparency and consistency [17].