Literature DB >> 32005253

Comparison of the SuperARMS and ARMS for detecting EGFR mutations in liquid-based cytology specimens from NSCLC patients.

Wei Wu, Ziyang Cao, Wei Zhang1, Liping Zhang1, Likun Hou1, Chunyan Wu2.   

Abstract

BACKGROUND: Non-surgical cytological specimens are adequate not only for accurate histological subtyping but also for molecular profiling. A modified amplification refractory mutation system polymerase chain reaction (ARMS PCR), known as SuperARMS PCR, was improved by optimizing the primers designation, which provides a higher sensitivity and specificity approach for free plasma DNA detection. It is unclear whether SuperARMS PCR detects epidermal growth factor receptor (EGFR) mutations in cytology samples. The aim of this study was to compare the EGFR mutations detected by ARMS PCR and SuperARMS PCR in cytology samples derived from advanced non-small cell lung cancer (NSCLC) patients.
METHODS: From March 2016 to March 2018, a total of 234 cytological samples were obtained from primary or metastatic lesions of NSCLC, including 144 fine-needle aspirations (FNAs), 36 endobroncheal ultrasonography (EBUS) FNAs, 36 transbronchial needle aspirations (TBNAs) and 18 pleural effusion (PLEs). EGFR mutations were simultaneously detected using an ADx-ARMS EGFR kit (Amoy Diagnostics CO., ltd., Xiamen, China) and an ADx-SuperARMS EGFR kit (Amoy Diagnostics CO., ltd., Xiamen, China). Digital droplet PCR (ddPCR) and next-generation sequencing (NGS) were further used to verify the EGFR mutant inconsistent samples.
RESULTS: All of the 234 patients with advanced or recurrent NSCLC were diagnosed and assessed by two cytopathologists, and their EGFR mutation statuses were successfully detected by ARMS and SuperARMS. Importantly, the SuperARMS and ARMS methods showed a highly concordant result of 94.0% (220/234) (95%CI: 85.0, 95.0%). The positive rate of the SuperARMS was higher than the ARMS in the cytology samples for EGFR detection (46.2% vs. 40.2%). The specific EGFR mutation sites in 16 samples (6.8%) were not completely consistent between the SuperARMS and ARMS. A total of 14 patients showed EGFR mutations when detected by SuperARMS, but by ARMS there were EGFR wild-type. Two patients were detected as having one more EGFR mutation site by SuperARMS than by ARMS. ddPCR and NGS were used to further confirm the EGFR mutations in these inconsistent samples. Eight samples had the same mutation results as the SuperARMS, and 6 samples were not verified because the remaining DNA was insufficient. A total of 78 EGFR mutation patients received Tyrosine Kinase Inhibitor (TKI) treatment. The overall objective response rate (ORR) was 88.5% (69/78) for EGFR TKI treatment.
CONCLUSION: SuperARMS showed a high sensitivity and specificity for EGFR detection and thus, is expected to become a routine test in the clinic to be used as a widely available, easy-to-operate and sensitive method for EGFR mutation detection in liquid-based cytology samples.

Entities:  

Keywords:  ARMS; EGFR; Liquid-based cytology; NSCLC; SuperARMS

Mesh:

Substances:

Year:  2020        PMID: 32005253      PMCID: PMC6995041          DOI: 10.1186/s13000-019-0910-5

Source DB:  PubMed          Journal:  Diagn Pathol        ISSN: 1746-1596            Impact factor:   2.644


Introduction

Lung cancer remains the most common cause of cancer death worldwide. Approximately 70% of patients with non-small cell lung cancer (NSCLC) come to clinical attention at an advanced stage [1]. Small biopsy or cytological specimens may be a good choice in these patients, while they have no surgical options. The types of non-surgical cytological samples include fine-needle aspiration (FNA), endobronchial ultrasound-guided (EBUS) biopsy, transbronchial needle aspiration (TBNA), bronchoscopic brush (BB) and pleural effusion (PLE), which are reliable for the diagnosis and staging of thoracic malignancy, especially of NSCLC [2-6]. Many investigators report that cytological material obtained with minimally invasive procedures is adequate not only for accurate histological subtyping but also for molecular profiling [7-9]. In fact, studies have demonstrated optimal results using a multitude of cytological samples for molecular tests [10-12]. In our previous study, epidermal growth factor receptor (EGFR) mutation detection was performed by ARMS in liquid-based cytology samples from patients with NSCLC and their paired tissue samples, and the results of the two groups were identical [13]. Cytology specimens provide high quality DNA for the evaluation of clinically relevant mutations. Research groups, such as Allegrini S and Malapelle U, have also directly used liquid-based cytology samples for EGFR and Kirsten rat sarcoma viral oncogene (KRAS) mutation detection with better results [14, 15]. Under an era of individualized targeted therapy for NSCLC, it is crucial, for guiding treatment decisions, to obtain informative cytological material for both diagnosis and molecular testing. In our lab, we have increasingly used cytology specimens for molecular testing when cytology material was the only specimen source available. Amplification Refractory Mutation System (ARMS) is an improved polymerase chain reaction (PCR) system and is an important platform for the detection of genes that drive NSCLC. The AmoyDx EGFR 29 Mutations Detection Kit is approved by the China Food and Drug Administration (CFDA) for the clinical testing of EGFR mutations using tissue samples. Recently, a novel technique called SuperARMS, which is a modified version of ARMS that optimizes the primers designation, was shown to provide a high sensitivity and specificity approach for free plasma DNA detection. No studies have been performed to compare ARMS and SuperARMS for EGFR mutation using cytology specimens. Therefore, it is unclear whether SuperARMS can be used to detect EGFR mutations in cytology samples and if it improves the sensitivity compared with ARMS. Thus, we conducted the present study to compare the EGFR mutations detected by ARMS and SuperARMS PCR in cytology samples derived from advanced NSCLC patients.

Materials and methods

Cytology specimens and study design

From March 2016 to March 2018, a total of 234 patients with advanced NSCLC were retrospectively enrolled in this study at the Shanghai Pulmonary Hospital, Tongji University. All the cytological samples were obtained from primary or metastatic lesions of NSCLC and included 144 FNAs, 36 EBUS FNAs, 36 TBNAs and 18 PLEs. The imaging data were independently reviewed by the authors to evaluate their treatment responses according to the Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1. Progression-free survival (PFS) was calculated from the date of the initiating tyrosine kinase inhibitors (TKI) treatment to a radiologic or clinical observation of the disease progression. A flowchart describing the study design is presented in Fig. 1. The study protocol was approved by the Institute Review Board of the Shanghai Pulmonary Hospital.
Fig. 1

A flowchart describing the study design

Abbreviations: NSCLC = non-small cell lung cancer; EGFR = epidermal growth factor receptor; NGS = next-generation sequencing.

A flowchart describing the study design Abbreviations: NSCLC = non-small cell lung cancer; EGFR = epidermal growth factor receptor; NGS = next-generation sequencing.

Sample collection

The liquid-based cytology specimen preparations were handled according to the standard specimen processing protocols in our laboratory. Cytology samples from FNAs, EBUS FNAs, TBNAs and PLEs were taken by clinicians and sent to pathology department for Thinprep cytologic test (TCT) within 1 day. One ThinPrep slide was stained with hematoxylin and eosin (H&E) from the various cell types and was reviewed for morphologic evaluation by two cytopathologists. The remainder of the specimen liquid-based cytology specimens were rinsed in CytoLyt solution (Hologic) and were centrifuged to generate a cell pellet stored at 4 °C. If the H&E–stained smear was positive for NSCLC, we quantitated the number of tumor cells as more than 200 cells by the H&E–stained smear and observed the residual cell pellet, which was visible to the naked eye, to ensure that the specimen was adequate for EGFR molecular testing.

DNA extraction

The residual cell pellets were used for the DNA extraction, which was performed using a Tissue DNA Kit (Amoy Diagnostics Co., Xiamen, China), following the manufacturer’s instructions. The optical density of the extracted DNA samples was measured using a microplate spectrophotometer (Biotek). The A260/A280 value of all the samples was 1.8 to 2.1. The extracted DNA was used for EGFR molecular testing.

EGFR mutation detection

The EGFR mutations in the residual liquid-based cytology samples were simultaneously detected using an ADx-ARMS EGFR kitand an ADx-SuperARMS EGFR kit, according to the manufacturer’s instructions. Briefly, the DNA templates were added to the EGFR Reaction Mix, which included the primers, probes, dNTPs, buffer, Mg2+ and Taq DNA polymerases. The PCR reactions were performed on a Stratagene Mx3000P quantitative PCR (qPCR) system. After the PCR reaction was completed, the data interpretation was conducted according to results interpretation criteria of the EGFR mutation detection kit.

ddPCR detection

The ddPCR was performed according to the manufacturer’s instructions. Briefly, the mutant reaction solution was prepared, and then, the emulsified microdroplets were generated in the QX200TM Droplet Generator instrument and were put into a 96-well plate for amplification. The PCR reaction conditions were as follows: incubation at 95 °C for 10 min, followed by 45 cycles of 95 °C for 15 s and 60°Cfor 60 s. After the PCR amplification, the 96-well plate was placed in the QX200 microdrop analyzer, and the data analyses were conducted using Quanta Soft analysis software.

NGS detection

DNA sequencing was carried out using a capture-based sequencing panel (Amoy Diagnostics CO., Ltd., Xiamen, China). The kit covered the targeted drug-related hot spot mutation regions of 10 genes, including EGFR et al. The liquid-based cytology DNA samples were sequenced with a NextSeq 500 (Illumina, Inc), with pair-end reads, with a reading length of PE150 and a sequencing depth of > 10,000x. The sequence data were analyzed using the AmoyDx NGS Data Analysis System ADXLC10 module (Amoy Diagnostics CO., Ltd., Xiamen, China).

Statistical analysis

The statistical analyses were performed with SPSS, version 17.0 (IBM, Armonk, NY). A two-sided tailed Fisher’s exact test was applied to the data for one subgroup with a count less than 5. p < 0.05 was considered significantly different.

Results

Patient characteristics

A total of 234 patients with advanced or recurrent NSCLC were retrospectively enrolled into the study. The patients’ clinical characteristics are listed in Table 1. The median age was 65 years (range, 31–85 years). The patients consisted of 79 women and 155 men. Eighty-four patients were smokers, 145 were never-smokers, and 5 were unclear smokers. Fifty-eight patients were classified as at stage III, and 176 were at stage IV. The liquid-based cytology sample types included: FNA from the lungs for 114 patients, FNA from the lymph nodes for 30 patients, EBUS for 36 patients, TBNA for 36 patients and PLE for 15 patients. All the specimens were confirmed by two cytopathologists, including 172 adenocarcinoma, 21 squamous and 41 NSCLC.
Table 1

Clinical characteristics (n = 234)

FactorsNo.(%)
Sex
 Male155(48.7%)
 Female79(48.7%)
Age, years
 Median65
 Range31–85
Smoking history
 Never145(62.0%)
 Former/current84(35.9%)
 Unclear5(2.1%)
Pathology
 Adenocarcinoma172(73.5%)
 Squamous21(9.0%)
 NSCLC41(17.5%)
Tumor Stage
 III58(24.8%)
 IV176(75.2%)
Cytological sample types
 FNA (lung)114(48.7%)
 FNA (lymph node)30(12.8%)
 EBUS FNA36(15.4%)
 TBNA36(15.4%)
 Pleural effusion18(7.7%)
Clinical characteristics (n = 234)

Comparisons of the SuperARMS and the ADx-ARMS for detecting EGFR in the cytological specimens

All 234 liquid-based cytology samples were successfully detected for their EGFR mutation status by ARMS and SuperARMS. The results are shown in Table 2. When tested by ARMS, 94 of 234 (40.2%) patients were identified to have an EGFR mutation. When using the SuperARMS, 108 of 234 (46.2%) patients were demonstrated to have an EGFR mutation. The positive rate of the SuperARMS was higher than the ARMS in the cytology samples for EGFR detection (46.2% vs. 40.2%). The two-sided tailed Fisher’s exact test showed that this was a significant difference (p < 0.05). The negative results and the positive results from the SuperARMS were in accordance with the ARMS results, at 90.0% (95% CI, 91.0,97.1%) and 100.0% (94/94), respectively. The concordance rate of the EGFR mutation status between SuperARMS and ARMS was 94.0% (220/234) (95%CI:85.0,95.0%). Fourteen patients showed an EGFR mutation by SuperARMS but were EGFR wild-type by ARMS. In addition, two patients were detected with one more EGFR mutation site by SuperARMS than by ARMS.
Table 2

Comparison of EGFR mutation status using ARMS and SuperARMS (N = 234)

ARMSTotal
MtWt
SuperARMSMt9414108
Wt0126126
Total94140234
PCR*100% (94/94)
NCR*90%(126/140)(95%CI:91.0,97.1%)
Overall agreement*94%(220/234)(95%CI:85.0,95.0%)

*percentage [95% confidence interval (CI)];

Mt: mutation; Wt: wild type; PCR: positive coincident rate; NPV: negative coincident rate

Comparison of EGFR mutation status using ARMS and SuperARMS (N = 234) *percentage [95% confidence interval (CI)]; Mt: mutation; Wt: wild type; PCR: positive coincident rate; NPV: negative coincident rate

SuperARMS for detecting specific EGFR mutation types

Out of total of 234 samples, 16 cases were discordant between SuperARMS and ARMS (Table 3). Among them, 14 (87.5%) cases were detected as positive for EGFR mutations only by SuperARMS, while the other two samples showed different mutations by these two methods. We performed ddPCR and NGS to further confirmed the inconsistent samples(n = 12/16, 4 samples were insufficient). 1 sample with EGFR 20-ins mutation (Sample ID:FK020) is beyond capability of ddPCR, so 11/12 samples were identified by ddPCR at first. Then we successful detected 5 sample using NGS (Table 3). 2 samples were negative for mutations。 2 samples had a special L858R mutation type (NM_005228.3: exon21:c.2573 T > G:p.L858R), which was only detected by NGS and SuperARMS. This observation indicates that SuperARMS and NGS methods can detect more sites of mutation than ARMS in the tested regions.
Table 3

Sixteen Nonconcordant Cases of SuperARMS and ARMS for Cytology EGFR Detection

Sample IDARMSSuper-ARMSddPCRNGS
FK00819-DEL19-DEL/T790 M19-DEL/T790 MNA
FK020WT20-INSNA20-INS
FK055WTL858RWTNE DNA
FK062WTL858RWTNM_005228.3:exon21:c.2573_2574delinsGT:p.L858R
FK066WTL858RWTNM_005228.3:exon21:c.2573 T > G:p.L858R
FK080WT19-DEL19-DELNA
FK108WTL858RL858RNA
FK129WTL858RNE DNANE DNA
FK130WTL858RNE DNANE DNA
FK135WT19-DEL19-DELNA
FK147WT19-DELWTWT
FK166WTL858RWTNE DNA
FK190WT19-DELWTWT
FK20619-DEL19-DEL/L858RNE DNANE DNA
FK220WT20-insNE DNANE DNA
FK221WT19-DEL/L858R19-DEL/L858RNA

*NE DNA: not enough DNA

Sixteen Nonconcordant Cases of SuperARMS and ARMS for Cytology EGFR Detection *NE DNA: not enough DNA

EGFR mutation status and prediction of EGFR-TKI efficacy

As shown in Table 4, out of the 94 positive EGFR mutation patients by ARMS, 77 patients received EGFR-TKI treatment. In another 14 patients with an EGFR mutation by SuperARMS, only 1 patient received EGFR-TKI treatment. The ORR was 88.5% (69/78) for EGFR TKI treatment. In patients with or without EGFR mutation, 81 received chemotherapy. The median PFS was significantly prolonged in the EGFR mutation patients compared with the EGFR wild-type patients (18.0 months vs 8.3 months, P < 0.01) (Fig. 2). These data suggested that EGFR mutation status in cytology samples detected by ARMS and SuperARMS is predictive of tumor response to EGFR-TKIs and survival results.
Table 4

EGFR Mutation Status and TKIs treatment

Sample No.Positive No.Negtive No.Sensitive MT No.targeted therapy No.
ARMS234941409277
SuperARMS23410812610478
Fig. 2

PFS in EGFR mutation patients compared with EGFR wild-type patients

EGFR Mutation Status and TKIs treatment PFS in EGFR mutation patients compared with EGFR wild-type patients

Discussion

Currently, the molecular spectrum of tumor patients promotes the development of individualized treatment. Especially in patients with NSCLC, the mutation status of EGFR has great guiding significance for the use of TKIs [16]. Now more than ever, obtaining adequate material for the molecular testing of NSCLC is crucial. In the clinical setting, a cytological specimen may be the only material available for the determination of EGFR mutation status. Liquid-based cytology specimens have been used for molecular assays with optimal results, although rare large series have been published. It has been reported that the number of tumor cells in the remaining liquid base cell sample varies significantly between the different samples, with limited sensitivity of the ARMS detection in low tumor cell content samples [17]. SuperARMS is a highly sensitive kit that detects 41 EGFR mutations in exons 18 to 21 in human plasma cfDNA samples. To the best of our knowledge, ours is the first study to evaluate the performance of SuperARMS in liquid-based cytology samples for EGFR detection. The feasibility of conventional smears and the remaining liquid-based cytology samples for molecular detection has been evaluated in multiple laboratories [18-20]. Gilda da Cunha Santos’s team compared the nucleic acid quality of the remaining liquid-based cytology samples, smears and cell blocks for molecular detection, and found that well-preserved liquid-based cytology samples had a good nucleic acid yield and quality [21]. Maurizio Martini’s research team explained the role of cytological samples in tumor diagnosis, which is not only used in the diagnosis, but also in molecular testing, and a small amount of high-quality nucleic acid provides effective molecular genetic features [22]. Consistent with these reports in the literature, our liquid-based cytology samples had good DNA quality and or the EGFR gene status was successfully detected using SuperARMS and ARMS. In this study, various cytological specimens, including FNA, EBUS FNA, TBNA and PLE, were all subjected to the EGFR mutational analysis using SuperARMS and ARMS, and 100% (234/234) of the samples were suitable for testing. Firstly, the SuperARMS and ARMS methods showed highly concordant results, at 94.0% (220/234) (95%CI: 85.0, 95.0%). Moreover, SuperARMS detected more mutations compared with ARMS. Our study showed that SuperARMS, as a highly sensitive molecular detection method, can be used for the detection of EGFR not only in plasma ctDNA, but also in cytological samples DNA. The high sensitivity and specificity of SuperARMS has been demonstrated in a series of liquid biopsy studies [23, 24]. Our study confirmed that SuperARMS had high sensitivity and specificity in liquid-based cytology samples. The positive rate of SuperARMS was higher than ARMS in the cytology samples for EGFR detection (46.2% vs. 40.2%) (Table 2). Our study showed that SuperARMS was not only used in the blood, but also in liquid-based cytology samples. Is there a false positive result in the SuperARMS? We analyzed the reasons for the inconsistency of the results of the validation samples. The false positive results caused by the contamination of aerosol in the laboratory should be excluded. Notably that two samples had the special L858R mutation type (NM_005228.3: exon21:c.2573 T > G:p.L858R), which was detected by SuperARMS and NGS. The specific reason for this observation is that the SuperARMS and NGS methods detect more sites. Many previous studies report that there is a significant correlation between EGFR mutation status and treatment for PFS [25, 26]. Consistent with these studies, our study revealed that patients with EGFR mutations, using targeted drugs as the first line of treatment, had a longer PFS compared to patients without EGFR mutations, using chemotherapy drugs as the first line of treatment, as detected by both ARMS and SuperARMS. In conclusion, the SuperARMS had a high sensitivity and specificity for EGFR detection in liquid-based cytology samples, and these results were good predictors of the efficacy of EGFR-TKIs. Thus, the SuperARMS is expected to become a test that is used routinely in the clinic as a widely available, easy-to-operate and sensitive method for EGFR mutation detection in liquid-based cytology samples.
  24 in total

1.  Next-generation sequencing of liquid-based cytology non-small cell lung cancer samples.

Authors:  Jordan P Reynolds; Yaolin Zhou; Maureen A Jakubowski; Zhen Wang; Jennifer A Brainard; Roger D Klein; Carol F Farver; Francisco A Almeida; Yu-Wei Cheng
Journal:  Cancer Cytopathol       Date:  2017-01-13       Impact factor: 5.284

2.  The application of molecular diagnostic studies interrogating EGFR and KRAS mutations to stained cytologic smears of lung carcinoma.

Authors:  Bryan L Betz; Michael H Roh; Helmut C Weigelin; Jeremiah B Placido; Lindsay A Schmidt; Sara Farmen; Doug A Arenberg; Gregory P Kalemkerian; Stewart M Knoepp
Journal:  Am J Clin Pathol       Date:  2011-10       Impact factor: 2.493

Review 3.  Treatment choice in epidermal growth factor receptor mutation-positive non-small cell lung carcinoma: latest evidence and clinical implications.

Authors:  Oscar Juan; Sanjay Popat
Journal:  Ther Adv Med Oncol       Date:  2017-01-30       Impact factor: 8.168

Review 4.  To Obtain More With Less: Cytologic Samples With Ancillary Molecular Techniques-The Useful Role of Liquid-Based Cytology.

Authors:  Maurizio Martini; Sara Capodimonti; Tonia Cenci; Mirna Bilotta; Guido Fadda; Luigi Maria Larocca; Esther Diana Rossi
Journal:  Arch Pathol Lab Med       Date:  2018-03       Impact factor: 5.534

Review 5.  Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration for Diagnosis and Staging of Lung Cancer.

Authors:  David Fielding; Noriaki Kurimoto
Journal:  Clin Chest Med       Date:  2018-03       Impact factor: 2.878

6.  Use of SuperARMS EGFR Mutation Detection Kit to Detect EGFR in Plasma Cell-free DNA of Patients With Lung Adenocarcinoma.

Authors:  Shaohua Cui; Lin Ye; Huimin Wang; Tianqing Chu; Yizhuo Zhao; Aiqin Gu; Liwen Xiong; Chunlei Shi; Liyan Jiang
Journal:  Clin Lung Cancer       Date:  2017-12-21       Impact factor: 4.785

7.  Diagnostic utility and accuracy of rapid on-site evaluation of bronchoscopic brushings.

Authors:  Daniel P Steinfort; Tracy L Leong; Irena F Laska; Anne Beaty; Alpha Tsui; Louis B Irving
Journal:  Eur Respir J       Date:  2014-12-23       Impact factor: 16.671

8.  Epidermal growth factor receptor gene analysis with a highly sensitive molecular assay in routine cytologic specimens of lung adenocarcinoma.

Authors:  Sara Allegrini; Jlenia Antona; Rosanna Mezzapelle; Umberto Miglio; Alessia Paganotti; Claudia Veggiani; Milo Frattini; Guido Monga; Piero Balbo; Renzo Boldorini
Journal:  Am J Clin Pathol       Date:  2012-09       Impact factor: 2.493

9.  FNA smears as a potential source of DNA for targeted next-generation sequencing of lung adenocarcinomas.

Authors:  Amanda L Treece; Nathan D Montgomery; Nirali M Patel; Chris J Civalier; Leslie G Dodd; Margaret L Gulley; Jessica K Booker; Karen E Weck
Journal:  Cancer Cytopathol       Date:  2016-02-16       Impact factor: 5.284

10.  Role of the Endobronchial Landmarks Guiding TBNA and EBUS-TBNA in Lung Cancer Staging.

Authors:  S Arias; Q H Liu; B Frimpong; H Lee; D Feller-Kopman; L Yarmus; K P Wang
Journal:  Can Respir J       Date:  2016-12-12       Impact factor: 2.409

View more
  3 in total

Review 1.  Current and Emerging Applications of Droplet Digital PCR in Oncology: An Updated Review.

Authors:  Susana Olmedillas-López; Rocío Olivera-Salazar; Mariano García-Arranz; Damián García-Olmo
Journal:  Mol Diagn Ther       Date:  2021-11-13       Impact factor: 4.074

2.  Comparison of EGFR mutations detected by LNA-ARMS PCR in plasma ctDNA samples and matched tissue sample in non-small cell lung cancer patients.

Authors:  Jiahui Jin; Jingjing He; Xinyu Yan; Yaru Zhao; Haojie Zhang; Kai Zhuang; Yating Wen; Junzhen Gao
Journal:  Am J Transl Res       Date:  2022-08-15       Impact factor: 3.940

3.  Comparison of transbronchial needle aspiration with and without ultrasound guidance for diagnosing benign lymph node adenopathy.

Authors:  Hui Shen; Lingyun Lou; Ting Chen; Yi Zou; Bin Wang; Zhihao Xu; Qin Ye; Huahao Shen; Wen Li; Yang Xia
Journal:  Diagn Pathol       Date:  2020-04-15       Impact factor: 2.644

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.