Previous studies indicated that hardware removal may lead to increased morbidity and therefore, at least in adults, remains questionable for certain indications. However, risks such as corrosion or local reactions may be less likely in younger patients with current, improved hardware materials. We sought to retrospectively determine complication rates of hardware removal in pediatric upper limb surgery, and establish potential risk factors for increased morbidity.All children and adolescents who underwent inpatient hardware removal under anesthesia after previous upper limb surgery between 2002 and 2016 were retrospectively evaluated. The following details were extracted at the latest follow-up: demographics, implant location, hardware material, duration of surgery, duration of hardware in situ, and any complications graded according to Goslings et al (grade 0-5) and Sink et al (grade 1-5), respectively. Correlations were calculated to establish potential relationships between specific outcome parameters (e.g., location, duration of surgery etc.) and complication grades.A total of 2089 children were evaluated of whom 317 patients with 449 interventions (mean age 9.4 years) fulfilled the inclusion criteria for this study. Overall, 203 K-wires (46%), 97 plates (22%), 102 external fixators (23%), 32 intramedullary nails (7%), 6 screws (1%), 4 cerclages (1%) and 1 pin (0.2%) were removed; most common locations were the forearm (34%) and humerus (24%). The mean duration of surgery was 40 minutes (± 50.9), mean time in situ was 194 days (± 319.6). Complication rates were low overall, with most being grade 0 (n = 372; 83%) or 1 (n = 60; 13%) according to Goslings et al and grade 1 (n = 386; 86%) and 2 (n = 42; 9%) according to Sink et al. No severe complications were observed. The following predictors were related to the severity of the complications in linear regression analysis: more distal localizations, external fixators, longer duration of surgery and female sex.Hardware removal under anesthesia in the pediatric upper extremity has produced a low complication rate with no severe complications and can thus be considered to be safe. Increased morbidity occurred in more distal localizations, external fixators, longer surgeries and females.Level of Evidence: Therapeutic, Level IV.Entities:
Mesh:
Year: 2020 PMID: 32000443 PMCID: PMC7004601 DOI: 10.1097/MD.0000000000019010
Source DB: PubMed Journal: Medicine (Baltimore) ISSN: 0025-7974 Impact factor: 1.889
Frequencies (%) and localizations of hardware removal.
Figure 1Pie chart showing the number and percentage of removed orthopedic implants (n = 449).
Types of orthopedic implants based on the localization of implant removal.
Frequency (%) and types of complications.
Frequency (%) of complications based on the systems of Goslings et al and Sink et al.
Coefficients of the predictors with significant values in the two models (n = 449).