Literature DB >> 3199894

Elimination of breathing artefacts from impedance cardiograms at rest and during exercise.

O Eiken, P Segerhammar.   

Abstract

Mesh:

Year:  1988        PMID: 3199894     DOI: 10.1007/bf02441821

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  16 in total

1.  Left ventricular ejection and the Heather Index measured by non-invasive methods during postural changes in man.

Authors:  D W Hill; A J Merrifield
Journal:  Acta Anaesthesiol Scand       Date:  1976       Impact factor: 2.105

2.  The Minnesota impedance cardiograph- theory and applications.

Authors:  W G Kubicek; J Kottke; M U Ramos; R P Patterson; D A Witsoe; J W Labree; W Remole; T E Layman; H Schoening; J T Garamela
Journal:  Biomed Eng       Date:  1974-09

3.  The specific resistance of blood at body temperature.

Authors:  L A Geddes; C Sadler
Journal:  Med Biol Eng       Date:  1973-05

4.  Application of impedance cardiography to study of postural stress.

Authors:  J J Smith; J E Bush; V T Wiedmeier; F E Tristani
Journal:  J Appl Physiol       Date:  1970-07       Impact factor: 3.531

5.  A low-resistance flow meter for wide-range ventilatory measurement.

Authors:  O Wigertz
Journal:  Respir Physiol       Date:  1969-08

6.  Correlations between ejection times measured from the carotid pulse contour and the impedance cardiogram.

Authors:  M A Frey; B M Doerr
Journal:  Aviat Space Environ Med       Date:  1983-10

7.  Measurement of cardiac output by electrical impedance at rest and during exercise.

Authors:  J C Denniston; J T Maher; J T Reeves; J C Cruz; A Cymerman; R F Grover
Journal:  J Appl Physiol       Date:  1976-01       Impact factor: 3.531

8.  Cardiac responses to lower body negative pressure and dynamic leg exercise.

Authors:  O Eiken; H Bjurstedt
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1985

9.  Automatic determination of cardiac output using an impedance plethysmography.

Authors:  Y Miyamoto; T Tamura; T Mikami
Journal:  Biotelem Patient Monit       Date:  1981

10.  Cardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.

Authors:  A T Edmunds; S Godfrey; M Tooley
Journal:  Clin Sci (Lond)       Date:  1982-08       Impact factor: 6.124

View more
  3 in total

1.  Filtering respiration and low-frequency movement artefacts from the cardiogenic electrical impedance signal.

Authors:  S B Raza; R P Patterson; L Wang
Journal:  Med Biol Eng Comput       Date:  1992-09       Impact factor: 2.602

2.  Five-electrode field plethysmography technique for separation of respiration and cardiac signals.

Authors:  H Nakesch; H Pfützner; C Ruhsam; P Nopp; K Futschik
Journal:  Med Biol Eng Comput       Date:  1994-07       Impact factor: 2.602

3.  An open-source automated algorithm for removal of noisy beats for accurate impedance cardiogram analysis.

Authors:  Shafa-At Ali Sheikh; Amit Shah; Oleksiy Levantsevych; Majd Soudan; Jamil Alkhalaf; Ali Bahrami Rad; Omer T Inan; Gari D Clifford
Journal:  Physiol Meas       Date:  2020-08-11       Impact factor: 2.688

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.