Literature DB >> 31995836

Evaluating Usability of a Touchless Image Viewer in the Operating Room.

Markus Bockhacker1, Hannah Syrek2, Max Elstermann von Elster3, Sebastian Schmitt1, Henning Roehl1.   

Abstract

BACKGROUND: Availability of patient-specific image data, gathered from preoperatively conducted studies, like computed tomography scans and magnetic resonance imaging studies, during a surgical procedure is a key factor for surgical success and patient safety. Several alternative input methods, including recognition of hand gestures, have been proposed for surgeons to interact with medical image viewers during an operation. Previous studies pointed out the need for usability evaluation of these systems.
OBJECTIVES: We describe the accuracy and usability of a novel software system, which integrates gesture recognition via machine learning into an established image viewer.
METHODS: This pilot study is a prospective, observational trial, which asked surgeons to interact with software to perform two standardized tasks in a sterile environment, modeled closely to a real-life situation in an operating room. To assess usability, the validated "System Usability Scale" (SUS) was used. On a technical level, we also evaluated the accuracy of the underlying neural network.
RESULTS: The neural network reached 98.94% accuracy while predicting the gestures during validation. Eight surgeons with an average of 6.5 years of experience participated in the usability study. The system was rated on average with 80.25 points on the SUS.
CONCLUSION: The system showed good overall usability; however, additional areas of potential improvement were identified and further usability studies are needed. Because the system uses standard PC hardware, it made for easy integration into the operating room. Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2020        PMID: 31995836      PMCID: PMC6989265          DOI: 10.1055/s-0039-1701003

Source DB:  PubMed          Journal:  Appl Clin Inform        ISSN: 1869-0327            Impact factor:   2.342


  13 in total

1.  Learning rate for laparoscopic surgical skills on MIST VR, a virtual reality simulator: quality of human-computer interface.

Authors:  A Chaudhry; C Sutton; J Wood; R Stone; R McCloy
Journal:  Ann R Coll Surg Engl       Date:  1999-07       Impact factor: 1.891

2.  Debunking health IT usability myths.

Authors:  N Staggers; Y Xiao; L Chapman
Journal:  Appl Clin Inform       Date:  2013-05-28       Impact factor: 2.342

3.  Using a depth-sensing infrared camera system to access and manipulate medical imaging from within the sterile operating field.

Authors:  Matt Strickland; Jamie Tremaine; Greg Brigley; Calvin Law
Journal:  Can J Surg       Date:  2013-06       Impact factor: 2.089

4.  Touchfree medical interfaces.

Authors:  Nathaniel Rossol; Irene Cheng; Anup Basu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

5.  Enhancement of gesture recognition for contactless interface using a personalized classifier in the operating room.

Authors:  Yongwon Cho; Areum Lee; Jongha Park; Bemseok Ko; Namkug Kim
Journal:  Comput Methods Programs Biomed       Date:  2018-04-06       Impact factor: 5.428

6.  Hand-gesture-based sterile interface for the operating room using contextual cues for the navigation of radiological images.

Authors:  Mithun George Jacob; Juan Pablo Wachs; Rebecca A Packer
Journal:  J Am Med Inform Assoc       Date:  2012-12-18       Impact factor: 4.497

Review 7.  Touchless interaction with software in interventional radiology and surgery: a systematic literature review.

Authors:  André Mewes; Bennet Hensen; Frank Wacker; Christian Hansen
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-09-19       Impact factor: 2.924

Review 8.  Towards Usable E-Health. A Systematic Review of Usability Questionnaires.

Authors:  Vanessa E C Sousa; Karen Dunn Lopez
Journal:  Appl Clin Inform       Date:  2017-05-10       Impact factor: 2.342

9.  Informatics in Radiology: developing a touchless user interface for intraoperative image control during interventional radiology procedures.

Authors:  Justin H Tan; Cherng Chao; Mazen Zawaideh; Anne C Roberts; Thomas B Kinney
Journal:  Radiographics       Date:  2012-12-21       Impact factor: 5.333

10.  Gesture-Controlled Image Management for Operating Room: A Randomized Crossover Study to Compare Interaction Using Gestures, Mouse, and Third Person Relaying.

Authors:  Rolf Wipfli; Victor Dubois-Ferrière; Sylvain Budry; Pierre Hoffmeyer; Christian Lovis
Journal:  PLoS One       Date:  2016-04-15       Impact factor: 3.240

View more
  2 in total

1.  Human-Device Interaction in the Life Science Laboratory.

Authors:  Robert Söldner; Sophia Rheinländer; Tim Meyer; Michael Olszowy; Jonas Austerjost
Journal:  Adv Biochem Eng Biotechnol       Date:  2022       Impact factor: 2.768

2.  Agile, Easily Applicable, and Useful eHealth Usability Evaluations: Systematic Review and Expert-Validation.

Authors:  Irina Sinabell; Elske Ammenwerth
Journal:  Appl Clin Inform       Date:  2022-03-09       Impact factor: 2.762

  2 in total