Literature DB >> 31977972

Could HIV-1 RNA Testing be an Option as the Second Step in the HIV Diagnostic Algorithm?

Silvina Masciotra1, Wei Luo1, Rebecca Rossetti1, Tara Smith2, Steven Ethridge1, Kevin P Delaney1, Laura G Wesolowski1, S Michele Owen1.   

Abstract

BACKGROUND: There is benefit to early HIV-1 diagnosis and treatment, but there is no Food and Drug Administration-approved quantitative assay with a diagnostic claim. We compared the performance of the Hologic Aptima HIV-1 Quant (APT-Quant) and Aptima HIV-1 Qual (APT-Qual) assays for diagnostic use and the performance of a diagnostic algorithm consisting of Bio-Rad BioPlex 2200 HIV Ag-Ab assay (BPC) followed by APT-Quant (2-test) compared with BPC followed by Geenius HIV-1/2 supplemental assay (Geenius) with reflex to APT-Qual (3-test).
METHODS: Five hundred twenty-four plasma, which included 419 longitudinal specimens from HIV-1 seroconverters (78 were after initiating antiretroviral therapy [ART]) and 105 from ART-naive persons with established HIV-1 infections, were used to evaluate APT-Quant performance for diagnostic use. Specimens from 200 HIV-negative persons were used to measure specificity. For the algorithm comparison, BPC-reactive specimens were evaluated with the 2-test or 3-test algorithm. McNemar's test was used to compare performance.
RESULTS: The APT-Quant detected more samples early in infection compared with APT-Qual. The APT-Quant specificity was 99.8%. Before ART initiation, the algorithms performed similarly among samples from different stages of infection. After ART initiation, the 3-test algorithm performed significantly better (P = 0.0233).
CONCLUSIONS: The APT-Quant has excellent performance for diagnostic use. The 2-test algorithm works well in ART-naive samples, but its performance decreases after the IgG response is elicited and with ART-induced suppressed viremia. Providing confirmation and viral load assay with 1 test result could be advantageous for patient care. However, additional factors and challenges associated with the implementation of this 2-test algorithm, such as cost, specimen type, and collection need further evaluation.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31977972     DOI: 10.1097/OLQ.0000000000001137

Source DB:  PubMed          Journal:  Sex Transm Dis        ISSN: 0148-5717            Impact factor:   2.830


  3 in total

1.  Evaluation of SAMBA II: A Qualitative and Semiquantitative HIV Point-of-Care Nucleic Acid Test.

Authors:  Lauren R Violette; Andy Cornelius-Hudson; Madison Snidarich; Lisa A Niemann; Sonny Michael Assennato; Allyson Ritchie; Neha Goel; Pollyanna R Chavez; Steven F Ethridge; David A Katz; Helen Lee; Kevin P Delaney; Joanne D Stekler
Journal:  J Acquir Immune Defic Syndr       Date:  2022-04-15       Impact factor: 3.771

2.  An HIV Diagnostic Testing Algorithm Using the cobas HIV-1/HIV-2 Qualitative Assay for HIV Type Differentiation and Confirmation.

Authors:  Dana Duncan; John Duncan; Bastian Kramer; Alex Y Nilsson; Betiel Haile; Ann Butcher; Shikha Chugh; Paul Baum; Grace M Aldrovandi; Stephen Young; Ann K Avery; Karen Tashima; Alexandra Valsamakis; Joseph D Yao; Ming Chang; Robert W Coombs
Journal:  J Clin Microbiol       Date:  2021-06-18       Impact factor: 5.948

3.  Performance of an Alternative Laboratory-Based HIV Diagnostic Testing Algorithm Using HIV-1 RNA Viral Load.

Authors:  Marc A Pitasi; Shilpa N Patel; Laura G Wesolowski; Silvina Masciotra; Wei Luo; S Michele Owen; Kevin P Delaney
Journal:  Sex Transm Dis       Date:  2020-05       Impact factor: 3.868

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.