| Literature DB >> 31976313 |
Lei Li1,2, Tienan Feng3, Weituo Zhang3, Sumeng Gao1,2, Ruoyang Wang1,2, Wenwen Lv3, Tengteng Zhu3, Herbert Yu4, Biyun Qian3.
Abstract
BACKGROUND: Lung cancer is one of the leading diagnosed cancers worldwide, and microRNAs could be used as biomarkers to diagnose lung cancer. hsa-miR-195 has been demonstrated to affect the prognosis of NSCLC (non-small-cell lung cancer) in a previous study. However, the diagnostic value of hsa-miR-195-5p in lung cancer has not been investigated.Entities:
Year: 2020 PMID: 31976313 PMCID: PMC6961786 DOI: 10.1155/2020/7415909
Source DB: PubMed Journal: Int J Genomics ISSN: 2314-436X Impact factor: 2.326
Figure 1Expression of hsa-miR-195-5p in lung cancer patients, COPD patients, and normal controls. All datasets show higher expression of hsa-miR-195-5p in lung cancer and COPD patients compared with normal controls. Because of the absence of samples, some datasets do not contain all three population types.
Figure 2Expression of hsa-miR-195-5p in different sexes and smoking statuses among lung cancer and COPD patients. In most datasets, sex and smoking status of patients do not affect the expression of hsa-miR-195-5p. The expression of hsa-miR-195-5p is higher in females than in males.
Figure 3ROC curves of hsa-miR-195-5p to distinguish lung cancer patients, COPD patients, and normal controls. In all three datasets, hsa-miR-195-5p showed good performance in distinguishing between lung cancer or COPD patients and normal controls, but not between lung cancer and COPD patients.
Figure 4Coexpression network and Ingenuity Pathway Analysis of hsa-miR-195 in the TCGA lung cancer patients The ROC curve of hsa-miR-195 combined with hsa-miR-143 to distinguish lung cancer patients and normal controls in another two datasets. (a) The network analysis shows another microRNA highly correlated with hsa-miR-195. (b, c) Ingenuity Pathway Analysis shows that the IL-8 signaling pathway was the most important pathway in this network. (d, e) The combination of hsa-miR-195 and hsa-miR-143 has a better performance in distinguishing lung cancer patients and normal controls compared with hsa-miR-195 alone.
Statistical parameters of has-mir-195-5p combined with has-mir-143 to distinguish lung cancer and normal.
| Parameter |
|
|
|---|---|---|
| Sensitivity | 0.79 | 0.99 |
| Specificity | 1.00 | 0.83 |
| False positive rate | 0.00 | 0.17 |
| False negative rate | 0.21 | 0.02 |
| Accuracy | 0.84 | 0.95 |
| Kappa | 0.62 | 0.85 |
| AUC | 0.92 | 0.97 |