Literature DB >> 31972772

Identifying Cochlear Implant Channels With Relatively Poor Electrode-Neuron Interfaces Using the Electrically Evoked Compound Action Potential.

Kelly N Jahn1,2, Julie G Arenberg1,2.   

Abstract

OBJECTIVES: The primary objective of this study was to quantify local (within ear) and global (between ear) variation in the cochlear implant (CI) electrode-neuron interface (ENI) using the electrically evoked compound action potential (ECAP). We tested the hypothesis that, within an ear, ECAP measures can be used to identify channels with presumed good and poor ENIs, which may be influenced by a combination of spiral ganglion neuron (SGN) density, electrode position, and cochlear resistivity. We also hypothesized that ECAP responses would reflect age-related differences in the global quality of the ENI between younger and older listeners who theoretically differ in SGN density.
DESIGN: Data were obtained from 18 implanted ears (13 individuals) with Advanced Bionics HiRes 90K devices. Six participants (8 ears) were adolescents or young adults (age range: 14-32 years), and 7 participants (10 ears) were older adults (age range: 54-88 years). In each ear, single-channel auditory detection thresholds were measured on channels 2 through 15 in response to a spatially focused electrode configuration (steered quadrupolar; focusing coefficient = 0.9). ECAP amplitudes, amplitude growth function (AGF) slopes, and thresholds were assessed on a subset of channels in each ear in response to three interphase gaps (0, 7, and 30 µs). ECAP peak amplitudes were assessed on all channels between 2 and 15. AGFs and ECAP thresholds were measured on the two nonadjacent channels with the lowest and highest focused behavioral thresholds in each ear. ECAP responses were compared across low- and high-threshold channels and between younger and older CI listeners.
RESULTS: Channels that were estimated to interface poorly with the auditory nerve (i.e., high-focused-threshold channels) had steeper ECAP AGF slopes, smaller dynamic ranges, and higher ECAP thresholds than channels with low focused thresholds. Younger listeners had steeper ECAP AGF slopes and larger ECAP peak amplitudes than older listeners. Moreover, younger listeners showed greater interphase gap sensitivity for ECAP amplitude than older listeners.
CONCLUSIONS: ECAP responses may be used to quantify both local (within ear) and global (between ear) variation in the quality of the ENI. Results of this study support future investigation into the use of ECAP responses in site-selection CI programming strategies. The present results also support a growing body of evidence suggesting that adolescents and young adults with CIs may have denser populations of functional SGNs relative to older adults. Potential differences in global SGN integrity between younger and older listeners warrant investigation of optimal CI programming interventions based on their divergent hearing histories.

Entities:  

Mesh:

Year:  2020        PMID: 31972772     DOI: 10.1097/AUD.0000000000000844

Source DB:  PubMed          Journal:  Ear Hear        ISSN: 0196-0202            Impact factor:   3.570


  8 in total

1.  Effects of Age and Cochlear Implantation on Spectrally Cued Speech Categorization.

Authors:  Mishaela DiNino; Julie G Arenberg; Anne L R Duchen; Matthew B Winn
Journal:  J Speech Lang Hear Res       Date:  2020-06-18       Impact factor: 2.297

2.  Single-Channel Focused Thresholds Relate to Vowel Identification in Pediatric and Adult Cochlear Implant Listeners.

Authors:  Meisam K Arjmandi; Kelly N Jahn; Julie G Arenberg
Journal:  Trends Hear       Date:  2022 Jan-Dec       Impact factor: 3.496

Review 3.  Spectral Resolution Development in Children With Normal Hearing and With Cochlear Implants: A Review of Behavioral Studies.

Authors:  Kelly N Jahn; Julie G Arenberg; David L Horn
Journal:  J Speech Lang Hear Res       Date:  2022-02-24       Impact factor: 2.674

4.  The Effect of Advanced Age on the Electrode-Neuron Interface in Cochlear Implant Users.

Authors:  Jeffrey Skidmore; Brittney L Carter; William J Riggs; Shuman He
Journal:  Ear Hear       Date:  2021-12-21       Impact factor: 3.562

5.  Recovery from forward masking in cochlear implant listeners: Effects of age and the electrode-neuron interface.

Authors:  Kelly N Jahn; Lindsay DeVries; Julie G Arenberg
Journal:  J Acoust Soc Am       Date:  2021-03       Impact factor: 1.840

6.  Assessing the relationship between neural health measures and speech performance with simultaneous electric stimulation in cochlear implant listeners.

Authors:  Florian Langner; Julie G Arenberg; Andreas Büchner; Waldo Nogueira
Journal:  PLoS One       Date:  2021-12-13       Impact factor: 3.240

7.  A Broadly Applicable Method for Characterizing the Slope of the Electrically Evoked Compound Action Potential Amplitude Growth Function.

Authors:  Jeffrey Skidmore; Dyan Ramekers; Deborah J Colesa; Kara C Schvartz-Leyzac; Bryan E Pfingst; Shuman He
Journal:  Ear Hear       Date:  2022 Jan/Feb       Impact factor: 3.562

8.  Correlation of Electrically Evoked Compound Action Potential Amplitude Growth Function Slope and Anamnestic Parameters in Cochlear Implant Patients-Identification of Predictors for the Neuronal Health Status.

Authors:  Lutz Gärtner; Katharina Klötzer; Thomas Lenarz; Verena Scheper
Journal:  Life (Basel)       Date:  2021-03-05
  8 in total