Performance Evaluation of a New Point of Care Viscoelastic Coagulation Monitoring System in Major Abdominal, Orthopaedic and Vascular Surgery.

Chris Brearton1, Andrew Rushton1, Jane Parker1, Hannah Martin2, Jake Hodgson2.   

Abstract

Viscoelastic Coagulation Testing (VCT), or Thromboelastography has the potential to improve the cost and clinical effectiveness of surgical and medical care by preventing unnecessary treatment and by improving treatment for bleeding, via targeted transfusion strategies. Recently a new viscoelastic coagulation monitoring system, the VCM System, has been developed, which has several advantages over existing systems. The VCM system is a small, portable device, that is designed to be simple to operate and can be used to reliably perform viscoelastic testing at the patient's bedside. The aim of this study was to evaluate the performance of the VCM system by comparing it to that of the ROTEM® delta. The CT, CFT, alpha angle, A10, A20, MCF and lysis results obtained from blood samples run in parallel on the VCM System and the ROTEM® NATEM test were compared for 86 patients undergoing planned abdominal, major orthopedic or vascular surgery. There was good correlation between the VCM and ROTEM® NATEM tests results for CT, A10, A20 and MCF, with Spearman Rank values of 0.70, 0.80, 0.80 and 0.73 respectively. The correlation between the two systems for CFT and alpha was moderate (Spearman Rank values of 0.68 and 0.51). There was also good agreement between the lysis parameters for the two systems. No problems with the usability of the VCM system, or difficulties with training on the system were reported by any of the clinical staff involved in the study. The VCM system is capable of making viscoelastic measurements of the hemostasis of blood samples within a rapid timeframe and addresses the accessibility, robustness and training issues associated with the larger traditional systems.

Entities:  

Keywords:  Thromboelastography; VCM system; Viscoelastic testing; hemostasis

Mesh:

Substances:

Year:  2020        PMID: 31957529     DOI: 10.1080/09537104.2019.1704719

Source DB:  PubMed          Journal:  Platelets        ISSN: 0953-7104            Impact factor:   3.862


  4 in total

1.  Association of D-dimer and Fibrinogen With Hypercoagulability in COVID-19 Requiring Extracorporeal Membrane Oxygenation.

Authors:  Abhimanyu Chandel; Saloni Patolia; Mary Looby; Najeebah Bade; Vikramjit Khangoora; Christopher S King
Journal:  J Intensive Care Med       Date:  2021-03-01       Impact factor: 3.510

Review 2.  Viscoelastic Hemostatic Assays for Orthopedic Trauma and Elective Procedures.

Authors:  Christiaan N Mamczak; Jacob Speybroeck; John E Stillson; Joseph Dynako; Andres Piscoya; Ethan E Peck; Michael Aboukhaled; Emily Cancel; Michael McDonald; Diego Garcia; John Lovejoy; Stephanie Lubin; Robert Stanton; Matthew E Kutcher
Journal:  J Clin Med       Date:  2022-07-12       Impact factor: 4.964

Review 3.  Hemorrhagic Resuscitation Guided by Viscoelastography in Far-Forward Combat and Austere Civilian Environments: Goal-Directed Whole-Blood and Blood-Component Therapy Far from the Trauma Center.

Authors:  James H Lantry; Phillip Mason; Matthew G Logsdon; Connor M Bunch; Ethan E Peck; Ernest E Moore; Hunter B Moore; Matthew D Neal; Scott G Thomas; Rashid Z Khan; Laura Gillespie; Charles Florance; Josh Korzan; Fletcher R Preuss; Dan Mason; Tarek Saleh; Mathew K Marsee; Stefani Vande Lune; Qamarnisa Ayoub; Dietmar Fries; Mark M Walsh
Journal:  J Clin Med       Date:  2022-01-12       Impact factor: 4.241

Review 4.  The Non-Activated Thromboelastometry (NATEM) Assay's Application among Adults and Neonatal/Pediatric Population: A Systematic Review.

Authors:  Petroula Georgiadou; Rozeta Sokou; Andreas G Tsantes; Stavroula Parastatidou; Aikaterini Konstantinidi; Dimitra Houhoula; Styliani Kokoris; Nicoletta Iacovidou; Argirios E Tsantes
Journal:  Diagnostics (Basel)       Date:  2022-03-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.