Dual-Tuned Removable Common-Mode Current Trap for Magnetic Resonance Imaging and Spectroscopy.

Angel G Enriquez, Jana M Vincent, Joseph V Rispoli.   

Abstract

Magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) are preferred methods of gathering structural and metabolic information from the body due to their non-invasive approach to obtaining a diagnosis. Dual-tuned radiofrequency (RF) coils can detect signals produced by both hydrogen and a second atomic nuclei of interest. However, undesired electromagnetic coupling often confounds both the design and utilization of RF coils. Coaxial shield currents, also known as common-mode currents, can be induced during MR scans and cause image distortion and reduction in signal-to-noise ratio (SNR); furthermore, the energy dissipated from the cabling can create heat that poses a risk of patient burns if the routed too closely. Thus, common-mode currents must be suppressed in RF coils by employing non-magnetic current traps. In this paper, we present a novel dual-tuned current trap that is fully removable and does not require soldering directly to the cable. The design was manufactured with 3D printing to support rapid fabrication and distribution. Bench measurements at the 3T Larmor frequencies for hydrogen and phosphorous-31 demonstrate common-mode attenuation of -18 dB and -8.4 dB respectively.

Entities:  

Mesh:

Year:  2019        PMID: 31947402      PMCID: PMC7068692          DOI: 10.1109/EMBC.2019.8857944

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  8 in total

1.  Investigation of the factors responsible for burns during MRI.

Authors:  M F Dempsey; B Condon; D M Hadley
Journal:  J Magn Reson Imaging       Date:  2001-04       Impact factor: 4.813

2.  Mechanism of burn injury during magnetic resonance imaging (MRI)--simple loops can induce heat injury.

Authors:  T Nakamura; K Fukuda; K Hayakawa; I Aoki; K Matsumoto; T Sekine; H Ueda; Y Shimizu
Journal:  Front Med Biol Eng       Date:  2001

Review 3.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

Review 4.  Proton and multinuclear magnetic resonance spectroscopy in the human brain at ultra-high field strength: A review.

Authors:  Anke Henning
Journal:  Neuroimage       Date:  2017-07-13       Impact factor: 6.556

Review 5.  Theory and application of array coils in MR spectroscopy.

Authors:  S M Wright; L L Wald
Journal:  NMR Biomed       Date:  1997-12       Impact factor: 4.044

6.  Safety testing and operational procedures for self-developed radiofrequency coils.

Authors:  Jens Hoffmann; Anke Henning; Ioannis A Giapitzakis; Klaus Scheffler; G Shajan; Rolf Pohmann; Nikolai I Avdievich
Journal:  NMR Biomed       Date:  2015-04-06       Impact factor: 4.044

7.  4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy.

Authors:  N I Avdievich; H P Hetherington
Journal:  J Magn Reson       Date:  2007-03-03       Impact factor: 2.229

8.  Trap Design and Construction for High-Power Multinuclear Magnetic Resonance Experiments.

Authors:  Joseph V Rispoli; Ivan E Dimitrov; Sergey Cheshkov; Craig Malloy; Steven M Wright; Mary P McDougall
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2016-11-17       Impact factor: 1.176