Martin Koller1, Elisabeth Steyer1, Kerstin Theisen1, Sami Stagnell2, Norbert Jakse2, Michael Payer2. 1. Division of Preventive and Operative Dentistry, Endodontics, Periodontology, Prosthodontics, Restorative Dentistry and Implantology, Department of Dental Medicine and Oral Health, School of Dentistry, Medical University Graz, Graz, Austria. 2. Division of Oral Surgery and Orthodontics, Department of Dental Medicine and Oral Health, School of Dentistry, Medical University Graz, Graz, Austria.
Abstract
OBJECTIVES: To prospectively evaluate, as part of an ongoing randomized pilot trial, the clinical outcomes of two-piece zirconia implants in comparison with titanium implants 80 months after delivery of all-ceramic (lithium disilicate) single-tooth restorations. MATERIAL AND METHODS: The original sample included 31 (16 zirconia and 15 titanium) implants in 22 healthy patients. In addition to evaluating implant survival and success, a number of clinical or radiographic parameters were statistically analyzed: plaque index (PI), bleeding on probing (BOP), pink esthetic score (PES), and marginal bone loss (MBL). Both implant groups were compared using a Mann-Whitney U test. RESULTS: Three implants (2 zirconia and 1 titanium) had been lost, so that 28 implants (14 zirconia and 14 titanium) in 21 patients could be evaluated after a mean of 80.9 (SD: 5.5) months. All surviving implants had remained stable, in the absence of any fixture or abutment fractures and without any chipping, fracture, or debonding of crowns. The zirconia implants were associated with PI values of 11.07% (SD: 8.11) and the titanium implants with 15.20% (SD: 15.58), the respective figures for the other parameters being 16.43% (SD: 6.16) or 12.60% (SD: 7.66) for BOP; 11.11 (SD: 1.27) or 11.56 (SD: 1.01) for PES; and 1.38 mm (SD: 0.81) or 1.17 mm (SD: 0.73) for MBL. CONCLUSIONS: No significant differences were found between the clinical outcomes of two-piece zirconia and titanium implants based on the aforementioned parameters after 80 months of clinical service. Our results should be interpreted with the limited sample size in mind.
RCT Entities:
OBJECTIVES: To prospectively evaluate, as part of an ongoing randomized pilot trial, the clinical outcomes of two-piece zirconia implants in comparison with titanium implants 80 months after delivery of all-ceramic (lithium disilicate) single-tooth restorations. MATERIAL AND METHODS: The original sample included 31 (16 zirconia and 15 titanium) implants in 22 healthy patients. In addition to evaluating implant survival and success, a number of clinical or radiographic parameters were statistically analyzed: plaque index (PI), bleeding on probing (BOP), pink esthetic score (PES), and marginal bone loss (MBL). Both implant groups were compared using a Mann-Whitney U test. RESULTS: Three implants (2 zirconia and 1 titanium) had been lost, so that 28 implants (14 zirconia and 14 titanium) in 21 patients could be evaluated after a mean of 80.9 (SD: 5.5) months. All surviving implants had remained stable, in the absence of any fixture or abutment fractures and without any chipping, fracture, or debonding of crowns. The zirconia implants were associated with PI values of 11.07% (SD: 8.11) and the titanium implants with 15.20% (SD: 15.58), the respective figures for the other parameters being 16.43% (SD: 6.16) or 12.60% (SD: 7.66) for BOP; 11.11 (SD: 1.27) or 11.56 (SD: 1.01) for PES; and 1.38 mm (SD: 0.81) or 1.17 mm (SD: 0.73) for MBL. CONCLUSIONS: No significant differences were found between the clinical outcomes of two-piece zirconia and titanium implants based on the aforementioned parameters after 80 months of clinical service. Our results should be interpreted with the limited sample size in mind.
Authors: Frank Akito Spitznagel; Marc Balmer; Daniel B Wiedemeier; Ronald Ernst Jung; Petra Christine Gierthmuehlen Journal: Clin Oral Implants Res Date: 2021-11-05 Impact factor: 5.021