The electronic nose technology in clinical diagnosis: A systematic review.

Mariana Valente Farraia1, João Cavaleiro Rufo2, Inês Paciência1,2,3, Francisca Mendes1, Luís Delgado4,5, André Moreira1,2,6.   

Abstract

BACKGROUND: Volatile organic compounds (VOC) are end products of human metabolism (normal and disease-associated) that can be mainly excreted in breath, urine, and feces. Therefore, VOC can be very useful as markers of diseases and helpful for clinicians since its sampling is noninvasive, inexpensive, and painless. Electronic noses, or eNoses, provide an easy and inexpensive way to analyze gas samples. Thus, this device may be used for diagnosis, monitoring or phenotyping diseases according to specific breathprints (breath profile).
OBJECTIVE: In this review, we summarize data showing the ability of eNose to be used as a noninvasive tool to improve diagnosis in clinical settings.
METHODS: A PRISMA-oriented search was performed in PubMed and Cochrane Library. Only studies performed in humans and published since 2000 were included.
RESULTS: A total of 48 original articles, 21 reviews, and 7 other documents were eligible and fully analyzed. The quality assessment of the selected studies was conducted according to the Standards for Reporting of Diagnostic Accuracy. Airway obstructive diseases were the most studied and Cyranose 320 was the most used eNose.
CONCLUSIONS: Several case-control studies were performed to test this technology in diverse fields. More than a half of the selected studies showed good accuracy. However, there are some limitations regarding sampling methodology, analysis, reproducibility, and external validation that need to be standardized. Additionally, it is urgent to test this technology in intend-to-treat populations. Thus, it is possible to think in the contribution of VOC analysis by eNoses in a clinical setting.
Copyright © 2019 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of PBJ-Associação Porto Biomedical/Porto Biomedical Society. All rights reserved.

Entities:  

Keywords:  breathomics; diagnosis; electronic nose; volatile organic compounds

Year:  2019        PMID: 31930178      PMCID: PMC6924976          DOI: 10.1097/j.pbj.0000000000000042

Source DB:  PubMed          Journal:  Porto Biomed J        ISSN: 2444-8664


Introduction

Biochemical and biomolecular diagnostic methods used in medicine have their focus on blood and urine analysis. Breath analysis using electronic nose technology (eNose) could integrate the current examination procedures to assist clinicians in diagnosis and monitoring, since it is a noninvasive sampling technique, painless, inexpensive and that can be easily performed by sick patients, children, and elderly alike.[1] The potential of exhaled breath analysis appeared with Hippocrates when he described an odor of fetor hepaticus as a clinical marker which is now related with hepatic diseases.[2,3] The compounds related with that smell were later discover by gas chromatography coupled with mass spectrometry (GC-MS). Breath of patients with hepatic conditions showed higher levels of dimethyl sulfide, acetone, 2-butanone, and 2-pentanone and lower levels of indole and dimethyl selenide.[3] Nowadays, exhaled breath is not the only type of sample used for gas analysis which can include fecal and urine headspaces. The term “headspace” is referred as the gas directly surrounding a sample. The constituents of the sample which have a high volatility will generally be present in the headspace in higher concentrations.[4] Low volatile compounds are less likely to be found in a sample. Consequently, the concentration of molecules present in the headspace is not proportional to the concentration of the same molecules in liquid or solid sample. The electronic nose or eNose is “an instrument which comprises an array of electronic chemical sensors with partial specificity and an appropriate patter-recognition system, capable of recognizing simple or complex odours” (1994).[5] This device mimics the mammalian olfactory system and can identify different complex odors comparing the incoming odor with patterns previously learnt.[6] When an odor (chemical input) is presented to the eNose causes a physical change in the sensors which is detected by the transducers and converted into an electrical signal creating a specific signature or smellprint.[5] The rise and decline of the signal depends on some parameters: nature of the odor (type and concentration of the compounds), reaction and diffusion between odor and sensors, type of sensor, and ambient conditions.[5] Methods based on mass spectrometry analysis can detect and identify which compounds are present in air samples being useful for pathophysiologic research.[7] Yet, these methods are time consuming, expensive, and depend on a skilled operator which makes them unpractical to be applied at clinical settings. Electronic noses have the potential to overcome these disadvantages because they are relatively inexpensive, easy to use and provide a rapid analysis.[5] To achieve this goal, it is necessary to create a prediction model with a training set of samples and external validate the model for further application. The aim of this systematic review was to investigate how eNose technology may be applied as a noninvasive tool to improve diagnostic in clinical settings, based on published evidence. The clinical application of eNoses has been reviewed by some authors with special focus on pulmonary diseases, cancer, and gastroenterology.[8-10] In this review, all published studies using eNose to diagnosis, phenotyping or monitoring diseases, pulmonary and extra pulmonary, are listed and discuss.

Methods

Search strategy

This systematic review was conducted following the PRISMA statement for authors of systematic reviews by searching for studies using the eNose technology as a diagnostic tool in medicine.[11] The search was performed until the end of September 2017 in PubMed and Cochrane Library. The keywords “electronic nose” or “enose” and “diagnosis” or “diagnostic” or “phenotyping” or “phenotype” or “monitoring” were used. Full-text manuscripts in English published since January 2000, independently of the type of document (original article, review, comment, conference paper, letters, and book chapters), were assessed for eligibility. The adopted inclusion criteria were (a) diagnosis using electronic nose technology in clinical and medical applications; and (b) clinical trials. The exclusion criteria consisted of (a) trials not performed on human patients.

Quality assessment

The quality assessment of the selected studies was conducted according to the Standards for Reporting of Diagnostic Accuracy (STARD).[12] The STARD statement was created to improve the quality of reporting diagnostic accuracy studies and incorporates a checklist of 30 items divided in 5 groups, covering the main sections of a scientific article, that should be included in the report of those studies. To better represent the quality assessment, STARD quality scores were defined: items reported in the study were classified as “Yes” and added 1 point to the score; items not reported or unclear were classified as “No” and “Unclear,” respectively, and added 0 points to the score (see Supplemental Digital Content).

Results

Study selection, characterization, and quality assessment

The systematic search using the aforementioned methodology yielded 295 studies. After removal of duplicates, 286 studies were accepted for screening. However, this number was increased to 324 after the inclusion of studies found by reference list searching. During the screening of titles and abstracts using the prespecified inclusion criteria, 238 studies were rejected, yielding 86 studies for full revision. Each of those studies was then reviewed. Ten studies were later excluded: 4 articles were focused on eNose technology and other breath analysis methods, 3 were focused on volatile organic compounds (VOC) and associated diseases, and 3 studies regarded clinical application but not diagnosis or monitoring of a disease. Reasons to exclude the studies at this stage were discussed with members of the review team. Thus, 76 studies were included: 48 original articles, 21 reviews, and 7 other documents (comments, letters, and book chapter). Figure 1 shows the flow diagram of search and selection process.
Figure 1

Summary of the literature search.

Summary of the literature search. The eNose technology applied in health field was tested in several diseases to verify its potential on diagnosis or monitoring. The diseases in which this technology was tested can be divided into 5 groups: airway obstructions, respiratory infections, inflammatory diseases, cancer, and other diseases. Airway obstructions group is the one which includes more research and published studies (18 original articles). Chronic obstructive pulmonary disease (COPD) and asthma are the most studied diseases using the eNose technology as a diagnostic tool, followed by obstructive sleep apnea syndrome (OSAS). The second group with 9 studies includes ear, nose, and throat (ENT) infections, ventilator-associated pneumonia (VAP), invasive aspergillosis (IA), and late-onset sepsis (LOS). The inflammatory diseases with only 5 studies are sarcoidosis, inflammatory bowel disease, arthritis, inflammatory answer to ozone, and acute respiratory distress syndrome (ARDS). Furthermore, this technology has been applied to investigate the possibility of diagnosis different type of cancers, such as lung cancer, prostate cancer, colonrectal cancer, and malignant pleural mesothelioma (MPM). The other diseases that have been under investigation are cystic fibrosis, halitosis, amyotrophic lateral sclerosis (ALS), and renal dysfunction. The most commonly used eNose, in 81% of the studies, was the Cyranose 320 (Sensigent, Baldwin Park, CA) and the most current methodology for sampling collection consisted of using Tedlar Bags for trapping the exhaled breath after 5 minutes of tidal breathing through a VOC filter, to eliminate the influence of environmental VOC in the samples and was primarily described by Dragonieri et al.[13] This methodology was used in 44% of the studies. Considering a cross-validation value (CVV) or an area under the curve (AUC) of 80% or more, 50% of the studies achieved those requirements (65% if we consider only studies that presented CVV or AUC values). However, only 10% of all studies performed external validation in a new recruited population. The summarized overview of the collected information is presented at Table 1   , and most important outcomes are presented in the discussion (Table 1   ). Table 2  presents the main results of reviews, comments, and book chapters found in the literature (Table 2 ).
Table 1

Characteristics and main results of the included original studies

Table 1 (Continued)

Characteristics and main results of the included original studies

Characteristics and main results of the included original studies Characteristics and main results of the included original studies Characteristics and main results of the included original studies Characteristics and main results of the included original studies Characteristics and main results of the included studies (reviews, comments, and book chapters) Characteristics and main results of the included studies (reviews, comments, and book chapters)

Study population

An overview of the included studies is presented in Table 1   . The population used in each study vary significantly, from 10 (3 cases and 7 controls) to 171 participants (25 cases and 166 controls). In several studies, control group was composed by healthy subjects but in some cases participants with other health conditions or with smoking habits were included. The studies were conducted in several countries of Europe, North America, Asia, and Australia. The leader country with more investigation in this field was the Netherlands, with 19 studies. Seven studies evaluated more than 1 condition per survey, supporting the potential of using eNose for differential diagnosis.

Discussion

Diagnosis of airway obstructive diseases

The present review study presents an overview of eNose performance on diagnosis and phenotyping of diseases. Most of the included studies (18 original articles) concerned common airway obstructive diseases, such as COPD and asthma, and the VOC patterns were analyzed to differentiate these conditions, or to compare them with breathprints of other airway diseases, such as lung cancer. Dragonieri et al found that COPD and nonsmall cell lung cancer have different exhaled VOC patterns which could be distinguished by eNose with a CVV of 85%.[14] Furthermore, patients with nonsmall cell lung cancer could also be distinguished from healthy controls with a CVV of 80% or 90% when duplicates measurements were analyzed. At the same year, Fens et al published a study aiming to separate VOC profiles between COPD and asthma patients.[15] They found different breath profiles between asthma subjects and COPD patients with an accuracy of 96%, as well as between nonsmoking controls and smoking controls with accuracies values of 95% and 92.5%, respectively. Later, the same group of authors conducted a study to externally validate the previous results, following STARD guidelines.[16] The external validity of breath profiles showed that fixed asthma and classic asthma can be discriminated from COPD patients with high accuracy (88% and 83%, respectively) and sensitivity and specificity values varied from 85% up to 91% and 90%, respectively. Fens et al were able to differentiate mild and moderate types of COPD not only using eNose technology but also using mass spectrometry (GC-MS) and computed tomography scanning.[18] Interestingly, the group found that eNose breathprints could be related with activation markers of eosinophils and neutrophils in mild asthma, suggesting that the eNose may not only be useful for asthma diagnosis, but also for phenotyping. Another successful application of the eNose was demonstrated in a study where individuals with COPD were discriminated according to their alpha 1-antitrypsin deficiency.[19] The eNose was also able to discriminate COPD patients with and without airway bacterial colonization or identify the presence of a viral or bacterial cause in acute exacerbations.[20,21] However, the first study using breathprint analysis of exhaled VOC by an eNose in airway obstructions was conducted in patients with mild and severe asthma.[13] In this study, the degree of asthma severity was not discriminated by eNose, although it was able to distinguish asthma patients from controls with an accuracy of 90%. These results were further confirmed by another group and a sensitivity of 80% was reached, despite the low specificity of 65%.[24] These results can be explained by the differences in methodologies, namely due to the effects of treatment that was discontinued in one of the studies. Nevertheless, changes in the airway caliber in asthma have been shown to not affect the breathprints.[23] A recent study involving asthmatic subjects was conducted in Spain and aimed to phenotype the disease using the eNose.[25] The eNose was able to differentiate inflammatory phenotypes (eosinophilic, neutrophilic, and paucigranulocytic) in patients with persistent asthma with sensitivities and specificities ranging from 55% up to 94% and 79% up to 87%, respectively. Exhaled breath profiles of patients with asthma were also evaluated in a longitudinal study using 2 different approaches to analyze breath samples (GC-MS and eNose).[26] Both technologies were able to distinguish breathprints of patients collected during baseline, loss of control, and during recovery time. eNose technology had a higher accuracy than mass spectrometry (86–95% and 68–77%, respectively). OSAS was primarily investigated by Benedek et al that discovered the potential of the eNose technology in discriminating OSAS from non-OSAS patients in a pediatric population (sensitivity: 78%, specificity: 70%, AUC: 0.80).[28] These results are similar to those reported by Greulich et al (sensitivity: 93%, specificity: 70%, AUC: 0.85).[29] Obesity was also found to affect the pattern of exhaled breath since obese patients with OSAS were discriminated from health controls (cross validation accuracy [CVA]: 97.4%), but were only moderate distinct from obese patients without OSAS (CVA: 67.6%).[30] In a pilot study, OSAS breathprints were compared to OVS (overlap syndrome) and COPD.[31] Patients with OSAS clustered distinctly from those with OVS as well as from those with COPD (AUC: 1.00 and 0.83), but patients with OVS were not significantly different from those with COPD (AUC: 0.60). The significant interest of researchers in studying eNose technology as a diagnosis tool is notable, especially concerning airway obstructive diseases. Clinical diagnosis can be difficult because of related symptoms between different diseases, which makes breathprint analysis very useful if further research confirms these primary results. Diagnosis is not the only application of breathprint analysis, as it also appears to be promising for the phenotyping and monitoring of diseases.

Diagnosis of infectious diseases

Infectious diseases are caused by pathogenic microorganisms that are known to produce specific VOC. Several groups hypothesized that eNose could be used as a noninvasive tool to identify specific signatures of these health conditions. The most studied condition was VAP, a type of lung infection. A group in the United States discovers that Cyranose 320 was capable to correlate different breathprints to a pneumonia score.[34] However, it was Schnabel et al that presented a more detailed study revealing a sensitivity of 88% and a specificity of 66% in the discrimination between VAP patients with a positive bronchoalveolar lavage test and healthy controls.[35] ENT infections are very common and the eNose technology, in a preliminary study with 90 patients, was able to identify the presence of bacterial infections in 88.2% of the cases.[40] This result was also obtained by Dutta et al that, additionally, was capable to distinguish between 3 classes of Staphylococcus aureus infections (MRSA, MSSA, and C-NS).[41] A more specific study was conducted in patients with a positive diagnosis for bacterial sinusitis.[42] The eNose could predict the diagnosis of sinusitis in at least 72% of the samples using the external validation methodology. However, no further studies aiming to predict ENT infections by eNose in patients were conducted since 2006. The most recent studies focused on diagnosis of IA and the prediction of LOS at a preclinical stage.[54,56] In the first one, eNose could established distinct VOC profile in patients with IA and controls with an AUC of 0.93.[54] In the last one, fecal VOC profile of preterm infants with LOS was discriminated from matched controls with a reasonable AUC of 0.70.[56] Microorganisms produce different VOC that can be detected in air samples by eNose. These studies showed that exhaled breath can be analyzed by eNose, but also fecal gas which showed distinct VOC profiles. The results are promising but further investigation is required.

Diagnosis of inflammatory diseases

There is some recent research in this field; however, the number of studies is still low. Dragonieri et al started to study sarcoidosis in 11 untreated patients, 20 treated pulmonary sarcoidosis patients and 25 healthy controls.[49] Patients with untreated sarcoidosis were distinguished from healthy controls with an AUC of 0.825 and a CVA of 83.3%. This number decreased when breathprints of untreated patients were compared with the treated group (CVA: 74.2%). ARDS was also a condition investigated in 58 patients and 92 controls.[48] The 2 groups were separated with an AUC of 0.71. Differential diagnosis of Crohn disease and ulcerative colitis yielded a promising result in a pediatric population during active and remissive disease.[57] The values of sensitivity and specificity varied from 88% up to 100% and 67% up to 100%, respectively. The eNose was also tested in rheumatoid arthritis and psoriatic arthritis yielded moderate to poor values of sensitivity and specificity.[58] Inflammatory diseases are less investigated, and more studies are required to confirm the aforementioned observations. Nevertheless, these results are promising, especially for sarcoidosis.

Diagnosis of cancer

More recently, the eNose technology has been tested to diagnose some types of cancer. Surprisingly, lung cancer was not the first research target. An Australian group reported that, in 88% of the cases, eNose could separate MPM patients from controls.[38] These results were similar to another study performed by Dragonieri et al.[39] Both studies included patients with significant asbestos exposure but without MPM to compare with the MPM group. MPM subjects could be discriminated from those with asbestos exposure (sensitivity: 92.3%, specificity: 85.7%, AUC: 0.917) and from controls (sensitivity: 92.3%, specificity: 69.2%, AUC: 0.893).[39] Lung cancer was then explored by McWilliams et al and it was found that in 80% of the cases, eNose measurements were able to distinguish lung cancer patients from high-risk smoking control subjects without cancer.[37] These results were similar to a previous study where eNose reached a performance of 80% of sensitivity and 48% of specificity.[36] Pilot studies in prostate, bladder, and colonrectal cancer using the air scape of urine and feces samples for analysis were conducted recently.[50-52] The ChemPro 100-eNose could discriminate prostate cancer and benign prostatic hyperplasia with moderate values of sensitivity and specificity of 78% and 67%, respectively.[52] Electronic nose could also separate bladder cancer and patients with benign urological condition with moderate to good sensitivity and specificity (75% and 86%, respectively).[51] Finally, Cyranose 320 was able to distinguish the fecal gas profile of 40 patients with colonrectal cancer, 60 patients with advanced adenomas, and 57 healthy controls.[50] Sensitivity and specificity varied from 62% up to 85% and 73% up to 87%. Cancer diagnosis using air analysis of exhaled breath, urine, and fecal samples is a recent focus of investigation, revealing promising results. Although cancers related to the respiratory system have been further studied, only pilot studies have been performed so far, and a validation of these results is still required.

Other diseases

The diagnosis by eNose was also applied to differentiate breathprints of cystic fibrosis (CF) and primary ciliary dyskinesia (PCD) patients in 2 different studies, showing different results.[45,46] The first reached a sensitivity of 84% and a specificity of 60%, when breathprints of both diseases were compared. Comparing both diseases with control group, similar results were observed (sensitivity: 88% and 84%; specificity: 52% and 60%).[45] The other study did not compare the 2 diseases.[46] Comparisons between CF or PCD and the control group showed a lower sensitivity when compared to the previous study (50% and 57%, respectively) but with a higher specificity (95% and 85%, respectively). The samples were analyzed with Cyranose 320 and both used a VOC filter to minimize the influence of environmental VOC on the breath profiles. The major difference was among the population, the first used children's breathing samples, while the last studied samples from young adults. Only 1 study evaluated the capacity of eNose to separate healthy subjects from patients with renal failure, yielding a correct classification of 95.2%.[55] However, a completely different methodology was used. Authors investigated body odor with the sensor head on the leg of patients. More recently, ALS was also investigated and breath profiles from patients were moderately discriminated from healthy controls (CVA: 75%).[53] Finally, oral malodor was assessed, and an AUC of 0.879 was reached comparing control subjects and malodor patients.[43] This technology can be explored and investigated to diagnose several diseases. Further research in other health conditions is expected to test the potential use of this diagnostic tool.

Limitations

There are some limitations in studies using eNose technology as a possible noninvasive diagnosis tool. The most evident is that eNose cannot identify and quantify the compounds present in the sample. Electronic noses are used to detect patterns and not individual molecules. Some studies have demonstrated an association between the eNose technology and mass spectrometry, yielding a more complete analysis.[17,18] However, breathprint analysis allows the quick and easy assessment of an exhaled breath sample with thousands of volatile molecules. Another limitation is related to exhale breath sampling since exogenous VOC can be present in samples. Breathprints are critically dependent on the methods of collection and sampling of exhaled breath. The most commonly used technique was described by Dragonieri et al.[13] Sample collection consists of asking patients to breath normally for 5 minutes through a 3-way nonrebreathing valve with a VOC filter at the inspiratory port and a silica filter at the expiratory port to promote inspiratory VOC filtering and air drying, respectively. Therefore, it is possible to minimize any influence of humidity and environmental VOC on exhaled VOC patterns.[13,15] After a maximal deep inspiration, patients exhaled a single vital capacity volume into a 10 L Tedlar bag connected to the expiratory port and silica reservoir.[13] Almost 50% of the studies described in this review used this sampling methodology. In addition to this method, researchers should also adopt a restrict protocol regarding to food and beverage intake prior to sampling. Sampling methods should be standardized to achieve comparable results between studies and to improve diagnostic accuracy. As a pioneer area, much of research involves pilot studies to evaluate the potential of eNose to discriminate breathprints of controls from patients with a specific disease. However, in the airway obstructions group, there are some recent studies that try to distinguish different stages and severities of a disease (mainly COPD and asthma).[17,25] This type of research is expected to increase once its clinical application becomes more evident, as well as studies to help in treatment management and guidance of therapies. The external validation allows to confirm and provide robustness to the obtained results. Unfortunately, only 5 studies performed external validation. External validation requires a training set and a validation set with newly recruited patients to assess the diagnostic accuracy.[16] In the future, this validation methodology should be more recurrent to give strength to the results and introduce this tool into real clinical practice. Additionally, STARD guidelines for diagnostic accuracy studies should be followed to increase transparency and strength of results. There are some limitations regarding to the methodology that should be solved to enable comparisons of results across studies. Still, it is necessary to do studies in larger populations to achieve robust results and include pediatric subjects, not just adults.

Future perspectives

In the future, research in this field is expected to increase due to the promising results demonstrated in previous studies, especially in airway obstructive diseases. The main objective is to achieve a universal methodology, with adequate reproducibility and repeatability, to enable comparisons between studies. External validation should be performed to increase robustness of the results. Subsequently, studies on larger, representative, and intend-to-treat populations are needed to evaluate this technology in a real clinical setting in the presence of several confounders. It should be emphasized that pediatric population must be included in further studies. Thereby, it is possible to think about a clinical application of eNose technology, firstly as a complementary diagnostic approach for other traditional tools.

Conclusions

In conclusion, there is a need for a simple, noninvasive, inexpensive, and easy-to-perform technique to assess complex biological samples. GC-MS studies already proven that air analysis, especially of exhaled breath, can be a tool to evaluate an individual's metabolic status (normal or disease-associated). In recent years, several studies using eNose technology to analyze gas samples have shown promising results to diagnose different diseases, not only respiratory but also infectious and inflammatory diseases and various types of cancers. Electronic nose analysis could be useful in a clinical setting because they are portable, easy to perform, inexpensive, rapid and do not require a specialized technician. Many of the previous studies have shown the moderate to good accuracy of this technology to differentiate several conditions from controls, especially airway obstructive diseases. However, it is a priority to create guidelines for standardized breath sampling, analysis and interpretation of the results. Additionally, it is necessary to externally validate the results in independent datasets of newly recruited patients to strengthen the results. Finally, studies on larger and representative populations are needed to test this technology in a real clinical setting. Reproducibility and repeatability of measurements using eNoses should also be studied and optimized to ensure comparable results.

Acknowledgments

The authors gratefully acknowledge funding from Project NORTE-01-0145-FEDER-000010—Health, Comfort and Energy in the Built Environment (HEBE), cofinanced by Programa Operacional Regional do Norte (NORTE2020), through Fundo Europeu de Desenvolvimento Regional (FEDER). The current work has been supported by the EXPOSE project, which is financed by FEDER/FNR and by Fundação para a Ciência e Tecnologia (EXPOSE 02/SAICT/2016—Project no. 023222).

Conflicts of interest

The authors declare no conflicts of interest.
Table 1 (Continued)

Characteristics and main results of the included original studies

Table 1 (Continued)

Characteristics and main results of the included original studies

Table 2

Characteristics and main results of the included studies (reviews, comments, and book chapters)

Table 2 (Continued)

Characteristics and main results of the included studies (reviews, comments, and book chapters)

  80 in total

Review 1.  Exhaled Molecular Fingerprinting in Diagnosis and Monitoring: Validating Volatile Promises.

Authors:  Agnes W Boots; Lieuwe D Bos; Marc P van der Schee; Frederik-Jan van Schooten; Peter J Sterk
Journal:  Trends Mol Med       Date:  2015-10       Impact factor: 11.951

2.  Electronic nose analysis of exhaled breath to diagnose ventilator-associated pneumonia.

Authors:  R M Schnabel; M L L Boumans; A Smolinska; E E Stobberingh; R Kaufmann; P M H J Roekaerts; D C J J Bergmans
Journal:  Respir Med       Date:  2015-09-30       Impact factor: 3.415

Review 3.  Exhaled breath analysis by electronic nose in respiratory diseases.

Authors:  Simone Scarlata; Giorgio Pennazza; Marco Santonico; Claudio Pedone; Raffaele Antonelli Incalzi
Journal:  Expert Rev Mol Diagn       Date:  2015-05-11       Impact factor: 5.225

4.  Use of an electronic nose to diagnose bacterial sinusitis.

Authors:  Erica R Thaler; C William Hanson
Journal:  Am J Rhinol       Date:  2006 Mar-Apr

5.  Prostate cancer: eNose--man's new best friend?

Authors:  Robert Phillips
Journal:  Nat Rev Urol       Date:  2014-03-18       Impact factor: 14.432

6.  Electronic nose can discriminate colorectal carcinoma and advanced adenomas by fecal volatile biomarker analysis: proof of principle study.

Authors:  Tim G de Meij; Ilhame Ben Larbi; Marc P van der Schee; Yvette E Lentferink; Tamara Paff; Jochim S Terhaar Sive Droste; Chris J Mulder; Adriaan A van Bodegraven; Nanne K de Boer
Journal:  Int J Cancer       Date:  2013-09-02       Impact factor: 7.396

Review 7.  Non-invasive biomarkers of lung inflammation in smoking subjects.

Authors:  M Malerba; P Montuschi
Journal:  Curr Med Chem       Date:  2012       Impact factor: 4.530

8.  Exhaled molecular profiles in the assessment of cystic fibrosis and primary ciliary dyskinesia.

Authors:  T Paff; M P van der Schee; J M A Daniels; G Pals; P E Postmus; P J Sterk; E G Haarman
Journal:  J Cyst Fibros       Date:  2013-01-27       Impact factor: 5.482

9.  Electronic nose breathprints are independent of acute changes in airway caliber in asthma.

Authors:  Zsofia Lazar; Niki Fens; Jan van der Maten; Marc P van der Schee; Ariane H Wagener; Selma B de Nijs; Erica Dijkers; Peter J Sterk
Journal:  Sensors (Basel)       Date:  2010-10-12       Impact factor: 3.576

10.  Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement.

Authors:  David Moher; Alessandro Liberati; Jennifer Tetzlaff; Douglas G Altman
Journal:  PLoS Med       Date:  2009-07-21       Impact factor: 11.069

View more
  14 in total

1.  Diagnostic Performance of Electronic Noses in Cancer Diagnoses Using Exhaled Breath: A Systematic Review and Meta-analysis.

Authors:  Max H M C Scheepers; Zaid Al-Difaie; Lloyd Brandts; Andrea Peeters; Bart van Grinsven; Nicole D Bouvy
Journal:  JAMA Netw Open       Date:  2022-06-01

Review 2.  Breath-Based Diagnosis of Infectious Diseases: A Review of the Current Landscape.

Authors:  Chiranjit Ghosh; Armando Leon; Seena Koshy; Obadah Aloum; Yazan Al-Jabawi; Nour Ismail; Zoe Freeman Weiss; Sophia Koo
Journal:  Clin Lab Med       Date:  2021-06       Impact factor: 2.172

Review 3.  Sniffing Out Urinary Tract Infection-Diagnosis Based on Volatile Organic Compounds and Smell Profile.

Authors:  Valentin-Mihai Dospinescu; Akira Tiele; James A Covington
Journal:  Biosensors (Basel)       Date:  2020-07-23

4.  Development of a Tuneable NDIR Optical Electronic Nose.

Authors:  Siavash Esfahani; Akira Tiele; Samuel O Agbroko; James A Covington
Journal:  Sensors (Basel)       Date:  2020-12-01       Impact factor: 3.576

5.  Exhaled volatile organic compounds for diagnosis of hepatocellular carcinoma.

Authors:  Thanikan Sukaram; Rossarin Tansawat; Terapap Apiparakoon; Thodsawit Tiyarattanachai; Sanparith Marukatat; Rungsun Rerknimitr; Roongruedee Chaiteerakij
Journal:  Sci Rep       Date:  2022-03-29       Impact factor: 4.379

6.  Detection of Liver Dysfunction Using a Wearable Electronic Nose System Based on Semiconductor Metal Oxide Sensors.

Authors:  Andreas Voss; Rico Schroeder; Steffen Schulz; Jens Haueisen; Stefanie Vogler; Paul Horn; Andreas Stallmach; Philipp Reuken
Journal:  Biosensors (Basel)       Date:  2022-01-26

Review 7.  Electronic Noses and Their Applications for Sensory and Analytical Measurements in the Waste Management Plants-A Review.

Authors:  Justyna Jońca; Marcin Pawnuk; Adalbert Arsen; Izabela Sówka
Journal:  Sensors (Basel)       Date:  2022-02-15       Impact factor: 3.576

8.  Quantitative GC-TCD Measurements of Major Flatus Components: A Preliminary Analysis of the Diet Effect.

Authors:  Rafael Freire; Marianela Mego; Luciana Fontes Oliveira; Silvia Mas; Fernando Azpiroz; Santiago Marco; Antonio Pardo
Journal:  Sensors (Basel)       Date:  2022-01-22       Impact factor: 3.576

9.  Exhaled volatile organic compounds analysis in clinical pediatrics: a systematic review.

Authors:  Rosa A Sola Martínez; José M Pastor Hernández; Óscar Yanes Torrado; Manuel Cánovas Díaz; Teresa de Diego Puente; María Vinaixa Crevillent
Journal:  Pediatr Res       Date:  2020-09-12       Impact factor: 3.756

10.  The Influence of Smoking Status on Exhaled Breath Profiles in Asthma and COPD Patients.

Authors:  Stefania Principe; Job J M H van Bragt; Cristina Longo; Rianne de Vries; Peter J Sterk; Nicola Scichilone; Susanne J H Vijverberg; Anke H Maitland-van der Zee
Journal:  Molecules       Date:  2021-03-04       Impact factor: 4.411