| Literature DB >> 31921902 |
Amanda L Bartier1, Aylin Atilla1, Rebecca Archer1, Grace P S Kwong1.
Abstract
Objective: This study aimed to determine the most appropriate suture bite and stitch interval (SBSI) size for closing feline linea alba. Study design: Randomized ex vivo mechanical testing. Sample population: Ventral abdominal walls from 35 male feline cadavers were harvested and separated into 125 segments.Entities:
Keywords: SBSI; bite size; cat; feline; linea alba; suture
Year: 2019 PMID: 31921902 PMCID: PMC6914685 DOI: 10.3389/fvets.2019.00441
Source DB: PubMed Journal: Front Vet Sci ISSN: 2297-1769
Total number of samples per test group.
| 3 | 7 | 9 | 14 | 30 |
| 5 | 9 | 9 | 15 | 33 |
| 7.5 | 9 | 9 | 15 | 33 |
| 10 | 7 | 9 | 13 | 29 |
| Total | 32 | 36 | 57 | 125 |
Number of samples that underwent mechanical and visual failure by bite size and location, and average load in N at point of failure or maximum displacement (n = 125).
| Bite size | |||||
| 3 | 3 (2.4) | 27 (21.6) | 14 (11.2) | 16 (12.8) | 23.8 (12.7) |
| 5 | 3 (2.4) | 30 (24.0) | 7 (5.6) | 26 (20.8) | 27.5 (12.1) |
| 7.5 | 4 (3.2) | 29 (23.2) | 3 (2.4) | 30 (24.0) | 19.2 (11.6) |
| 10 | 1 (0.8) | 28 (22.4) | 1 (0.8) | 28 (22.4) | 16.5 (8.0) |
| Location | |||||
| Cranial | 4 (3.2) | 28 (22.4) | 8 (6.4) | 24 (19.2) | 23.3 (13.7) |
| Umbilical | 1 (0.8) | 35 (28.0) | 4 (3.2) | 32 (25.6) | 22.8 (10.7) |
| Caudal | 6 (4.8) | 51 (40.8) | 13 (10.4) | 44 (35.2) | 20.5 (11.7) |
Logistic regression for mechanical failure (n = 125).
| Intercept | 6.46 | 1.31 | 640.07 | <0.001 |
| Load ( | −0.13 | 0.04 | 0.87 | <0.001 |
Figure 1Box-plot representing the load at maximum displacement and load at mechanical failure (n = 125): “y”—failed, “n”—did not fail. The bold horizontal line within the boxes indicate the median load values. The circular symbols indicate outlying data points.
Logistic regression for factors associated with visual failure (n = 125).
| Intercept | 3.27 | 1.32 | 26.42 | 0.01 |
| Bite size | ||||
| 3 mm bite | Ref | – | – | – |
| 5 mm bite | 1.29 | 0.60 | 3.64 | 0.030 |
| 7.5 mm bite | 2.21 | 0.74 | 9.07 | 0.003 |
| 10 mm bite | 3.24 | 1.10 | 25.59 | 0.003 |
| Weight (kg) | −0.66 | 0.27 | 0.52 | 0.016 |
Figure 2Expected load (black dot) with 95% CI (vertical bar) at failure or maximum displacement for each bite size and suture distance (x-axis: Bite Size) (n = 125). One star indicates groups are significantly different with P < 0.02, two stars indicates a significant difference of P < 0.001.
Linear regression for factors associated with load at failure or maximum displacement (n = 125).
| Intercept | 23.78 (2.06) | <0.001 | – | – |
| 3 mm bite (Reference) | 23.78ab | 19.69–27.86 | ||
| 5 mm bite | 3.77 (2.85) | 0.2 | 27.55a | 23.65–31.44 |
| 7.5 mm bite | −4.63 (2.85) | 0.1 | 19.15b | 15.26–23.05 |
| 10 mm bite | −7.23 (2.94) | 0.02 | 16.55b | 12.39–20.70 |
R.
Minimal number of samples per test group to achieve a power of 0.8 and alpha of 0.05.
| Mechanical failure per site | Dichotomous | 0.33 | 138 |
| Visual failure per site | Dichotomous | 1.06 | 46 |
| Load per bite | Continuous | 0.38 | 21 |
| Load per location | Continuous | 0.10 | 302 |