Accuracy (trueness and precision) of a dual-structured light facial scanner and interexaminer reliability.

Wenceslao Piedra-Cascón1, Matthew J Meyer2, Mohammad M Methani3, Marta Revilla-León4.   

Abstract

STATEMENT OF PROBLEM: Digital waxing procedures should be guided by facial references to improve the esthetic outcome of a restoration. The development of facial scanners has allowed the digitalization of the extraoral soft tissues of the patient's face. However, the reliability of facial digitizers is questionable.
PURPOSE: The purpose of this study was to evaluate the accuracy (trueness and precision) of extraoral 3D facial reconstructions performed by using a dual-structured light facial scanner and to measure the interexaminer variability.
MATERIAL AND METHODS: Ten participants were included. Six soft-tissue landmarks were determined on each participant, specifically reference (Ref), glabella (Gb), subnasal (Sn), menton (Me), chelion right (ChR), and chelion left (ChL). Interlandmark distances Ref-Sn, Sn-Gb, Ref-Gb, Sn-Me, and ChR-ChL (intercommissural) were measured by 2 different operators by using 2 different methods: directly on the participant' face (manual group) and digitally (digital group) on the 3D facial reconstruction of the participant (n=20). For the manual group, interlandmark measurements were made by using digital calipers. For the digital group, 10 three-dimensional facial reconstructions were acquired for each participant by using a dual-structured light facial scanner (Face Camera Pro Bellus; Bellus3D). Interlandmark measurements were made by using an open-source software program (Meshlab; Meshlab). Both operators were used to note 10 measurements for each manual and digital interlandmark distance per participant. The intraclass correlation coefficient between the 2 operators was calculated. The Shapiro-Wilk test revealed that the data were not normally distributed. The data were analyzed by using the Mann-Whitney U test.
RESULTS: Significant differences were found between manual and digital interlandmark measurements in all participants. The mean value of the manual and digital group discrepancy was 0.91 ±0.32 mm. The dual-structured light facial scanner tested obtained a trueness mean value of 0.91 mm and a precision mean value of 0.32 mm. Trueness values were always higher than precision mean values, indicating that precision was relatively high. The intraclass correlation coefficient between the 2 operators was 0.99.
CONCLUSIONS: The facial digitizing procedure evaluated produced clinically acceptable outcomes for virtual treatment planning. The interexaminer reliability between the 2 operators was rated as excellent, suggesting that the type of facial landmark used in this study provides reproducible results among different examiners.
Copyright © 2019 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 31918895     DOI: 10.1016/j.prosdent.2019.10.010

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Accuracy of Portable Face-Scanning Devices for Obtaining Three-Dimensional Face Models: A Systematic Review and Meta-Analysis.

Authors:  Hang-Nga Mai; Jaeil Kim; Youn-Hee Choi; Du-Hyeong Lee
Journal:  Int J Environ Res Public Health       Date:  2020-12-25       Impact factor: 3.390

2.  The Effect of Perioral Scan and Artificial Skin Markers on the Accuracy of Virtual Dentofacial Integration: Stereophotogrammetry Versus Smartphone Three-Dimensional Face-Scanning.

Authors:  Hang-Nga Mai; Du-Hyeong Lee
Journal:  Int J Environ Res Public Health       Date:  2020-12-30       Impact factor: 3.390

3.  Custom-made 3D-printed face masks in case of pandemic crisis situations with a lack of commercially available FFP2/3 masks.

Authors:  Gwen R J Swennen; Lies Pottel; Piet E Haers
Journal:  Int J Oral Maxillofac Surg       Date:  2020-04-02       Impact factor: 2.789

4.  Accuracy of Mobile Device-Compatible 3D Scanners for Facial Digitization: Systematic Review and Meta-Analysis.

Authors:  Hang-Nga Mai; Du-Hyeong Lee
Journal:  J Med Internet Res       Date:  2020-10-23       Impact factor: 5.428