Literature DB >> 31917764

Simultaneous Multislice Diffusion-Weighted Imaging of the Kidneys at 3 T.

Andrej Tavakoli, Julia Krammer1, UIrike I Attenberger2, Johannes Budjan1, Alto Stemmer3, Dominik Nickel3, Stephan Kannengiesser3, John N Morelli4, Stefan O Schoenberg1, Philipp Riffel1.   

Abstract

PURPOSE: The aim of this study was to compare respiratory-triggered diffusion-weighted imaging with simultaneous-multislice acceleration (SMS-RT-DWI) to a standard free-breathing echoplanar DWI (s-DWI) for 3 T renal imaging with respect to image quality and artifacts.
MATERIALS AND METHODS: A total of 40 patients who had undergone renal magnetic resonance imaging were included in this retrospective analysis of a prospectively planned cohort study. All examinations were performed on a 3 T whole-body magnetic resonance system. Both s-DWI and SMS-RT-DWI were obtained and images were independently reviewed by 2 radiologists on a 5-point Likert scale with respect to overall preference and image quality, renal edge and parenchymal sharpness, cortico-medullary differentiation, and sequence-related artifacts. Furthermore, discernibility of renal lesions was assessed. The signal-to-noise ratio (SNR) was measured from SNR maps. The derived mean apparent diffusion coefficients were also compared. Qualitative parameters were assessed with the Wilcoxon rank-sum test, and quantitative parameters, with the Student t test.
RESULTS: Overall image quality, renal edge, and parenchymal sharpness of SMS-RT-DWI were rated as superior to s-DWI by the readers, with fewer sequence-related artifacts (P < 0.01 for all). Lesion discernibility was significantly improved for SMS-RT-DWI (P < 0.01). Both readers preferred SMS-RT-DWI to s-DWI in all cases (40/40). The acquisition time for SMS-RT-DWI was 30% shorter than for s-DWI. Mean SNR heterogeneity of SMS-RT-DWI at b = 800 s/mm was statistically significantly lower than s-DWI, whereas mean SNR was significantly higher for SMS-RT-DWI. Mean apparent diffusion coefficient values from both sequences were comparably homogeneous throughout the kidneys.
CONCLUSION: Simultaneous multislice DWI of the kidney at 3 T with respiratory triggering yields substantially improved image quality and lesion discernibility compared with standard single-shot echoplanar DWI with a 30% reduction in scan acquisition time.

Entities:  

Mesh:

Year:  2020        PMID: 31917764     DOI: 10.1097/RLI.0000000000000637

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  6 in total

1.  Retrospective Distortion and Motion Correction for Free-Breathing DW-MRI of the Kidneys Using Dual-Echo EPI and Slice-to-Volume Registration.

Authors:  Jaume Coll-Font; Onur Afacan; Scott Hoge; Harsha Garg; Kumar Shashi; Bahram Marami; Ali Gholipour; Jeanne Chow; Simon Warfield; Sila Kurugol
Journal:  J Magn Reson Imaging       Date:  2020-12-31       Impact factor: 4.813

2.  Multi-band whole-body diffusion-weighted imaging with inversion recovery fat saturation: Effects of respiratory compensation.

Authors:  Solveig Kärk Abildtrup Larsen; Kim Sivesgaard; Erik Morre Pedersen
Journal:  Eur J Radiol Open       Date:  2021-08-26

3.  Improved Readout-Segmented Echo-Planner Diffusion-Weighted Magnetic Resonance Imaging of Nasopharyngeal Carcinoma Using Simultaneous Multislice Acquisitions at 3 T.

Authors:  Qiao Li; TingTing Jiang; TingTing Wang; Yan Huang; XiaoXin Hu; Ling Zhang; Wei Liu; CaiXia Fu; YaJia Gu
Journal:  J Comput Assist Tomogr       Date:  2022-04-26       Impact factor: 2.081

4.  Comparing the clinical utility of single-shot, readout-segmented and zoomit echo-planar imaging in diffusion-weighted imaging of the kidney at 3 T.

Authors:  Wenguang Liu; Hui Liu; Simin Xie; Ismail Bilal Masokano; Yu Bai; Xiao Wang; Linhui Zhong; Yi Wu; Jilin Nie; Gaofeng Zhou; Yigang Pei; Wenzheng Li
Journal:  Sci Rep       Date:  2022-07-20       Impact factor: 4.996

5.  Clinical Evaluation of an Abbreviated Contrast-Enhanced Whole-Body MRI for Oncologic Follow-Up Imaging.

Authors:  Judith Herrmann; Saif Afat; Andreas Brendlin; Maryanna Chaika; Andreas Lingg; Ahmed E Othman
Journal:  Diagnostics (Basel)       Date:  2021-12-16

6.  Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver.

Authors:  Hui Xu; Nan Zhang; Da-Wei Yang; Ahong Ren; Hao Ren; Qian Zhang; Jin-Xia Zhu; Gui-Jin Li; Zheng-Han Yang
Journal:  BMC Med Imaging       Date:  2021-09-09       Impact factor: 1.930

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.