| Literature DB >> 31911823 |
Rasmus Tolstrup Larsen1, Christoffer Brun Korfitsen1, Carsten Bogh Juhl2,3, Henning Boje Andersen4, Henning Langberg1, Jan Christensen5,6.
Abstract
BACKGROUND: Few studies have investigated the measurement properties of consumer-grade physical activity monitors (PAMs) in older adults. Therefore, we investigated the criterion validity of consumer-grade PAMs in older adults and whether the measurement properties differed between older adults with and without rollators and whether worn on the hip or at the wrist.Entities:
Keywords: Physical activity monitors; Technology; Validity; Walking
Year: 2020 PMID: 31911823 PMCID: PMC6942313 DOI: 10.1186/s11556-019-0235-0
Source DB: PubMed Journal: Eur Rev Aging Phys Act ISSN: 1813-7253 Impact factor: 3.878
Fig. 1a and b From left to right: Misfit Shine, Nokia GO, Jawbone UP Move and Garmin Vivofit 3 on paper with 10-mm grid lines. Figure a shows the hip-worn physical activity monitors and below figure b shows the wrist-worn physical activity monitors
Participants characteristics (n = 103)
| Sex, male, n (%) | 35 (34.0%) |
| Age, mean (95%CI) | 81.3 years (79.8 to 82.8) |
| Height, mean (95%CI) | 164.0 cm (162.2 to 165.9) |
| Body mass index, mean (95%CI) | 28.0 kg/m [ |
| Self-paced meters walked in 6 min, mean (95%CI) | 255.0 m (238.5 to 271.4) |
| Self-paced speed over the 6 min, mean (95%CI) | 2.6 km/t (2.4 to 2.7) |
| Walking without aid, n (%) | 52 (50.5%) |
| Walking with a cane, n (%) | 15 (14.5%) |
| Walking with a rollator, n (%) | 36 (35.0%) |
| Never smoked, n (%) | 44 (42.7%) |
| Stopped smoking, n (%) | 48 (46.6%) |
| Current smoker, n (%) | 11 (10.7%) |
Abbreviations: 95%CI: 95% Confidence interval; IQR Interquartile Range
Normal distributed continuous data: Age, Height, Body Mass Index, Meters walked in 6 min, Self-paced speed over the 6 min
A priori hypothesis for criterion validity, criterion validity, mean difference between measured steps and observed steps, and mean percentage measurement error for each physical activity monitor separately for each position
| Position and type of monitor | A priori hypothesis ICC(2,1) | ICC(2,1) | Mean difference | Mean % measurement error (95%CI) |
|---|---|---|---|---|
| Hip-worn Misfit Shine, left | ||||
| All (34 measures) | 0.5 to 0.75 | −61.99 (− 104.50 to − 19.50) | −12.46% (− 21.09 to − 3.83) | |
| Rollator (11 measures) | < 0.5 | −73.00 (− 163.94 to 17.94) | −15.87% (− 35.30 to 3.55) | |
| Without rollator (23 measures) | ≥ 0.75 | 0.49 (0.13 to 0.75) | −56.71 (− 107.56 to − 5.88) | − 10.83% (− 20.76 to − 0.90) |
| Hip-worn Misfit Shine, right | ||||
| All (88 measures) | 0.5 to 0.75 | −48.35 (− 74.47 to − 22.24) | −8.75% (− 14.10 to − 3.40) | |
| Rollator (31 measures) | < 0.5 | 0.44 (0.08 to 0.69) | − 110.19 (− 169.15 to − 51.24) | − 20.44% (− 31.87 to − 9.02) |
| Without rollator (57 measures) | ≥ 0.75 | −14.72 (− 36.11 to 6.65) | − 2.38% (− 7.39 to 2.61) | |
| Hip-worn Garmin Vivofit 3, left | ||||
| All (100 measures) | 0.5 to 0.75 | −41.49 (− 64.21 to − 18.76) | − 9.74% (− 15.16 to − 4.33) | |
| Rollator (36 measures) | < 0.5 | −87.5 (− 131.23 to − 43.83) | −20.61% (− 31.02 to − 10.18) | |
| Without rollator (64 measures) | ≥ 0.75 | 0.71 (0.56 to 0.81) | −15.59 (− 39.88 to 8.71) | −3.63% (− 9.42 to 2.16) |
| Hip-worn Garmin Vivofit 3, right | ||||
| All (102 measures) | 0.5 to 0.75 | −22,61 (− 37.50 to − 7.72) | − 5.18% (− 9.01 to − 1.36) | |
| Rollator (35 measures) | < 0.5 | −44.11 (− 70.02 to − 18.21) | − 10.12% (− 16.60 to − 3.64) | |
| Without rollator (67 measures) | ≥ 0.75 | −11.38 (− 29.46 to 6.70) | −2.61% (− 7.35 to 2.13) | |
| Hip-worn Jawbone UP Move, left | ||||
| All (84 measures) | 0.5 to 0.75 | −63.75 (− 87.94 to − 39.56) | −13.11% (− 18.24 to − 7.98) | |
| Rollator (23 measures) | < 0.5 | 0.40 (0.00 to 0.72) | − 101.65 (− 144.66 to − 58.64) | −19.21% (− 27.48 to − 10.94) |
| Without rollator (61 measures) | ≥ 0.75 | 0.64 (0.44 to 0.78) | −49.45 (− 78.44 to − 20.48) | − 10.81% (− 17.19 to − 4.43) |
| Hip-worn Jawbone UP Move, right | ||||
| All (92 measures) | 0.5 to 0.75 | 0.47 (0.21 to 0.65) | −85.79 (− 116.65 to − 54.95) | −16.57% (− 23.02 to − 10.12) |
| Rollator (31 measures) | < 0.5 | 0.24 (0.00 to 0.54) | − 193.83 (− 258.89 to − 128.78) | −38.28% (− 51.73 to − 24.84) |
| Without rollator (61 measures) | ≥ 0.75 | 0.68 (0.51 to 0.80) | − 30.89 (− 54.96 to − 6.83) | −5.53% (− 10.86 to − 0.20) |
| Wrist-worn Misfit Shine, left | ||||
| All (36 measures) | 0.5 to 0.75 | 0.18 (0.00 to 0.46) | −238.43 (−313.06 to − 163.81) | −44.21% (− 57.66 to − 30.78) |
| Rollator (12 measures) | < 0.5 | 0.00 (0.00 to 0.07) | − 486.5 (− 568.45 to − 404.55) | −91.03% (− 95.79 to − 86.27) |
| Without rollator (24 measures) | ≥ 0.75 | 0.37 (0.00 to 0.68) | − 114.40 (− 170.90 to − 57.89) | − 20.80% (− 31.65 to − 9.96) |
| Wrist-worn Misfit Shine, right | ||||
| All (88 measures) | 0.5 to 0.75 | 0.23 (0.00 to 0.47) | − 220.38 (− 266.13 to −174.64) | − 41.91% (− 50.49 to − 33.34) |
| Rollator (30 measures) | < 0.5 | 0.02 (0.00 to 0.09) | − 462.83 (− 518.31 to − 407.34) | −89.03% (− 97.04 to − 81.02) |
| Without rollator (58 measures) | ≥ 0.75 | 0.55 (0.10 to 0.77) | − 94.97 (− 124.91 to − 65.03) | − 17.55% (− 23.39 to − 11.71) |
| Wrist-worn Garmin Vivofit 3, left | ||||
| All (88 measures) | 0.5 to 0.75 | 0.31 (0.06 to 0.52) | − 139.71 (−186.39 to − 93.05) | − 27.17% (− 36.14 to − 18.20) |
| Rollator (22 measures) | < 0.5 | 0.00 (0.00 to 0.08) | − 455.78 (− 524.28 to − 387.27) | −88.31% (− 98.97 to − 77.67) |
| Without rollator (66 measures) | ≥ 0.75 | 0.67 (0.51 to 0.79) | −34.36 (− 61.45 to − 7.28) | −6.79% (− 12.43 to −1.15) |
| Wrist-worn Garmin Vivofit 3, right | ||||
| All (89 measures) | 0.5 to 0.75 | 0.33 (0.08 to 0.53) | − 132.98 (− 179.05 to − 86.91) | − 26.47% (− 35.62 to − 17.33) |
| Rollator (23 measures) | < 0.5 | 0.01 (0.00 to 0.08) | − 455.17 (− 519.00 to − 391.34) | −88.98% (− 98.99 to − 78.96) |
| Without rollator (66 measures) | ≥ 0.75 | −20.70 (− 42.4786 to 1.069512) | −4.69% (− 10.21 to 0.82) | |
| Wrist-worn Jawbone UP Move, left | ||||
| All (65 measures) | 0.5 to 0.75 | 0.30 (0.03 to 0.52) | − 121.52 (−166.86 to − 76.19) | −21.87% (− 30.14 to − 13.61) |
| Rollator (7 measures) | < 0.5 | 0.01 (0.00 to 0.23) | − 480.86 (− 640.08 to − 321.64) | −84.97% (− 110.58 to − 59.38) |
| Without rollator (58 measures) | ≥ 0.75 | 0.47 (0.18 to 0.68) | −78.15 (− 112.13 to − 44.18) | −14.25% (− 20.81 to − 7.70) |
| Wrist-worn Jawbone UP Move, right | ||||
| All (55 measures) | 0.5 to 0.75 | 0.29 (0.02 to 0.53) | − 105.05 (−148.00 to − 62.11) | −18.89% (− 26.65 to − 11.13) |
| Rollator (3 measures) | < 0.5 | 0.00 (0.00 to 0.88) | − 386.0 (− 1157.00 to 384.91) | − 66.17% (− 195.37 to 63.01) |
| Without rollator (52 measures) | ≥ 0.75 | 0.38 (0.06 to 0.61) | −88.84 (− 126.23 to − 51.46) | −16.16% (− 23.13 to − 9.19) |
Criterion validity calculated using a two-way random, single measures, absolute agreement model end expressed as interclass correlation coefficient
Abbreviations; ICC Interclass Correlation Coefficient (bold equal fulfilling the a priori hypothesis), MD Mean Difference: 95% Confidence intervals
Measurement error in % were evaluated as being not normally distributed and are presented with median and interquartile range. ICC (2, 1) values that meet the a priori hypothesis are marked with bold
Fig. 2Excluded data points as a percentage of total data points sorted on brand and position. Higher percentage equals more excluded data. Chi [2]-tests revealed a significant difference between brands (p < 0.001) hip and wrist positions (p < 0.001) but not between left and right positions (p = 0.816)
Fig. 3a, b and c Two-way scatter plots with logit link generalized linear models between absolute measurement error in % and observed steps (criterion) of Misfit Shine (a), Garmin Vivofit 3 (b) and Jawbone UP Move (c) physical activity monitors. Each figure includes results from the left hip, right hip, left wrist and right wrist. Red digits “1” and lines equal participants with rollators and blue digits “0” and lines equal participants without rollators. Y-axis represent absolute measurement error in % as a response to the x-axis which is number of observed steps