Literature DB >> 26907794

Validation of Fitbit-Flex as a measure of free-living physical activity in a community-based phase III cardiac rehabilitation population.

Muaddi Alharbi1, Adrian Bauman2, Lis Neubeck2, Robyn Gallagher2.   

Abstract

BACKGROUND: Accurate physical activity monitoring is important for cardiac patients. Novel activity monitoring devices may enable precise measurement of physical activity. This study aimed to validate Fitbit-Flex against Actigraph accelerometer for monitoring physical activity.
DESIGN: A validation study with a comparative design.
METHODS: Cardiac patients and family members participating in community-based exercise programs wore Fitbit-Flex and Actigraph simultaneously over four days to monitor daily step counts and minutes of moderate to vigorous physical activity (MVPA).
RESULTS: Participants (N = 48) comprised 52.1% males, with a mean age of 65.6 ± 6.9 years and 58.9% had a cardiac diagnosis. Fitbit-Flex and Actigraph were significantly correlated in males, females, total participants and cardiac patients for step counts (r = .96; r = .95; r = .95; r = .95), though less so for MVPA (r = .81; r = .65, r = .74; r = .71). As step counts increased the differences between Fitbit-Flex and Actigraph also increased. Fitbit-Flex over-estimated step counts in females (556 steps/day), males (1462 steps/day) and total participants (1038 steps/day) as well as for minutes of MVPA in females (4 min/day), males (15 min/day) and total participants (10 min/day). Fitbit-Flex had high sensitivity and specificity in classifying participants who achieved the recommended physical activity guidelines.
CONCLUSION: Fitbit-Flex is accurate in assessing attainment of physical activity guideline recommendations and is useful for monitoring physical activity in cardiac patients. The device does, however, slightly over-estimate step counts and MVPA. © The European Society of Cardiology 2016.

Entities:  

Keywords:  Actigraph; Coronary heart disease; Fitbit; accelerometer; activity monitor; cardiac rehabilitation; physical activity; validity

Mesh:

Year:  2016        PMID: 26907794     DOI: 10.1177/2047487316634883

Source DB:  PubMed          Journal:  Eur J Prev Cardiol        ISSN: 2047-4873            Impact factor:   7.804


  60 in total

Review 1.  Integrating Personalized Technology in Toxicology: Sensors, Smart Glass, and Social Media Applications in Toxicology Research.

Authors:  Stephanie Carreiro; Peter R Chai; Jennifer Carey; Brittany Chapman; Edward W Boyer
Journal:  J Med Toxicol       Date:  2017-04-12

Review 2.  Harnessing the Potential of Wearable Activity Trackers for Heart Failure Self-Care.

Authors:  Muaddi Alharbi; Nicola Straiton; Robyn Gallagher
Journal:  Curr Heart Fail Rep       Date:  2017-02

3.  Understanding physical activity lapses among women: responses to lapses and the potential buffering effect of social support.

Authors:  Leah M Schumacher; Danielle Arigo; Coco Thomas
Journal:  J Behav Med       Date:  2017-04-05

4.  An interpretable health behavioral intervention policy for mobile device users.

Authors:  X Hu; P-Y S Hsueh; C-H Chen; K M Diaz; F E Parsons; I Ensari; M Qian; Y-K K Cheung
Journal:  IBM J Res Dev       Date:  2018-01-25       Impact factor: 1.889

5.  Study protocol for a sequential multiple assignment randomized trial (SMART) to improve physical activity in employed women.

Authors:  Susan W Buchholz; JoEllen Wilbur; Shannon Halloway; Michael Schoeny; Tricia Johnson; Sachin Vispute; Spyros Kitsiou
Journal:  Contemp Clin Trials       Date:  2019-12-30       Impact factor: 2.226

6.  VALIDITY AND RELIABILITY OF THE FITBIT FLEX™ AND ACTIGRAPH GT3X+ AT JOGGING AND RUNNING SPEEDS.

Authors:  Denise Jones; Kay Crossley; Ben Dascombe; Harvi F Hart; Joanne Kemp
Journal:  Int J Sports Phys Ther       Date:  2018-08

7.  Physical activity patterns, adherence to using a wearable activity tracker during a 12-week period and correlation between self-reported function and physical activity in working age individuals with hip and/or knee osteoarthritis.

Authors:  Elin Östlind; Anita Sant'Anna; Frida Eek; Kjerstin Stigmar; Eva Ekvall Hansson
Journal:  BMC Musculoskelet Disord       Date:  2021-05-15       Impact factor: 2.362

8.  The Validity of MotionSense HRV in Estimating Sedentary Behavior and Physical Activity under Free-Living and Simulated Activity Settings.

Authors:  Sunku Kwon; Neng Wan; Ryan D Burns; Timothy A Brusseau; Youngwon Kim; Santosh Kumar; Emre Ertin; David W Wetter; Cho Y Lam; Ming Wen; Wonwoo Byun
Journal:  Sensors (Basel)       Date:  2021-02-18       Impact factor: 3.576

9.  Remote Exercise for Adults with Down Syndrome.

Authors:  Lauren T Ptomey; Amanda N Szabo; Erik A Willis; J Leon Greene; Jessica C Danon; Richard A Washburn; Daniel E Forsha; Joseph E Donnelly
Journal:  Transl J Am Coll Sports Med       Date:  2018-04-15

Review 10.  EVIDENCE Publication Checklist for Studies Evaluating Connected Sensor Technologies: Explanation and Elaboration.

Authors:  Christine Manta; Nikhil Mahadevan; Jessie Bakker; Simal Ozen Irmak; Elena Izmailova; Siyeon Park; Jiat-Ling Poon; Santosh Shevade; Sarah Valentine; Benjamin Vandendriessche; Courtney Webster; Jennifer C Goldsack
Journal:  Digit Biomark       Date:  2021-05-18
View more