| Literature DB >> 31908935 |
Wei Ji1, Yi-Jian Zhang1, Feng Zhou1, Hai-Qing Mao1, Hui-Lin Yang1, Tao Liu2,1.
Abstract
STUDYEntities:
Keywords: Cervical myelopathy; Clinical outcomes; Laminoplasty; Prospective study; Titanium miniplates
Year: 2019 PMID: 31908935 PMCID: PMC6939103 DOI: 10.1016/j.jot.2019.10.008
Source DB: PubMed Journal: J Orthop Translat ISSN: 2214-031X Impact factor: 5.191
Baseline patient characteristics .
| Variable | The 3 titanium miniplates group | The 5 titanium miniplates group | |
|---|---|---|---|
| N | 34 | 58 | — |
| Age (y) | 63.2 ± 6.1 | 60.7 ± 7.2 | 0.093 |
| Male | 25(73.5%) | 43(74.1%) | 0.949 |
| Underlying condition | |||
| Hypertension | 5(14.7%) | 7(12.1%) | 0.967 |
| Diabetes | 2(5.9%) | 3(5.2%) | 0.740 |
| Cardiovascular disease | 1(2.9%) | 1(1.7%) | 0.723 |
| Follow-up (mo) | 29.61 ± 8.17 | 32.26 ± 9.45 | 0.176 |
Values are expressed in mean ± standard deviation.
Abbreviations: N = number; Mo = months; y = years.
Comparison of intraoperative outcomes .
| Groups | Operation time(h) | Blood loss(ml) | Operation cost (RMB) |
|---|---|---|---|
| The 3 titanium miniplates group | 1.22 ± 0.65 h | 358.27 ± 101.51 | 48,854.73 ± 15,872.91 |
| The 5 titanium miniplates group | 2.37 ± 1.07 h | 410.33 ± 138.25 | 79,625.24 ± 16,811.46 |
| <0.001* | 0.030* | <0.001 |
Values are expressed in mean ± standard deviation.
Statistically significant: P < 0.05
Comparison of JOA score results .
| Variable | The 3 titanium miniplates group | The 5 titanium miniplates group | |
|---|---|---|---|
| Mean JOA score | |||
| Preop | 9.1 ± 1.6 | 8.9 ± 1.3 | 0.515 |
| 1 wk postop | 12.9 ± 0.8 | 13.1 ± 1.1 | 0.357 |
| 1 y postop | 15.1 ± 1.0 | 14.8 ± 1.0 | 0.168 |
| Mean recovery rate, % | |||
| 1 wk postop | 48.10 ± 9.26 | 51.85 ± 11.23 | 0.105 |
| 1 y postop | 75.95 ± 10.47 | 72.84 ± 10.84 | 0.180 |
Values are expressed in mean ± standard deviation.
JOA = Japanese Orthopaedic Association; ROM = range of motion; Preop = preoperative; Postop = postoperative.
Comparison of radiographic results of two groups .
| Variable | The 3 titanium miniplates group | The 5 titanium miniplates group | |
|---|---|---|---|
| CCA, deg | |||
| Preop | 21.2 ± 9.8 | 18.7 ± 8.3 | 0.515 |
| 3 mo postop | 19.8 ± 8.6 | 16.9 ± 7.0 | 0.357 |
| Last follow-up | 15.4 ± 8.2 | 13.7 ± 7.4 | 0.168 |
| ROM, deg | |||
| Preop | 43.75 ± 12.86 | 40.25 ± 11.37 | 0.178 |
| Last follow-up | 32.26 ± 10.01 | 30.94 ± 9.25 | 0.523 |
| The loss of ROM, % | 26.26 ± 8.31 | 23.13 ± 7.74 | 0.072 |
| Segments with stenosis | |||
| N | 2.68 ± 0.59 | 2.84 ± 0.62 | 0.202 |
| Preop CR | 0.47 ± 0.08 | 0.49 ± 0.08 | 0.374 |
| Postop CR | 0.64 ± 0.06 | 0.65 ± 0.07 | 0.488 |
| APD, mm | |||
| Preop | 10.35 ± 1.42 | 11.79 ± 1.65 | 0.102 |
| 1 wk postop | 18.25 ± 3.18 | 18.72 ± 2.74 | 0.456 |
| Last follow-up | 16.42 ± 2.53 | 17.32 ± 2.83 | 0.130 |
Values are expressed in mean ± standard deviation.
CCA= cervical curvature angle; ROM = range of motion; CR = compression ratio; APD = anteroposterior diameter; N = number; Preop = preoperative; Postop = postoperative.
Figure 1A 64-year-old male who underwent EOLP with 3 titanium miniplates. (A): Preoperative X-ray lateral view showing cervical vertebra bone matrix hyperplasia with multi-interspace. (B and C): Preoperative MRI (T2) sagittal view and axial view of C3/4 showing spinal cord with compression form C3 to C7, especially in C3/4. (D and E): X-ray lateral and direct view at postoperative 1 week showing the titanium miniplates in good position. (F): X-ray lateral view at postoperative 1 year showing all titanium miniplates in good position and without displacement. (G and H: MRI (T2) sagittal view and axial view of C3/4 at postoperative 2 years showing patient spinal cord without compression.
Figure 2A 63-year-old female who underwent EOLP with 5 titanium miniplates. (A): Preoperative X-ray lateral view revealed an abnormal curvature of cervical vertebra and narrowing of disc height. (B and C): Preoperative MRI (T2) sagittal view and axial view of C5/6 showing spinal cord compression from C4 to C6. (D and E): X-ray lateral and direct view at postoperative 1 week showing the titanium miniplates in good position. (F): X-ray lateral view at postoperative 1 year showing the titanium miniplates in good position and without displacement. (G and H): MRI (T2) sagittal view and axial view of C5/6 at postoperative 2 years showing patient spinal cord without compression.