Literature DB >> 3190764

Analysis of electric and magnetic fields leaking from induction heaters.

D Andreuccetti1, M Bini, A Ignesti, R Olmi, N Rubino, R Vanni.   

Abstract

Results are presented of an investigation on electric and magnetic fields leaking from inductive (magnetic) heaters that are used for thermal processing of high-power electron tubes and lasers in an industrial plant. Measurements of electric and magnetic fields were done using both commercially available and laboratory-developed instrumentation. Isotropic H-field sensors were developed to allow quantitative evaluation of high-intensity magnetic fields. Ten induction heaters with nominal A.C. power ranging from 2.5 kW to 15 kW and operating at frequencies between 300 kHz and 790 kHz were surveyed. Electric field strengths up to 8 kV/m and magnetic field strengths up to 20 A/m were measured.

Mesh:

Year:  1988        PMID: 3190764     DOI: 10.1002/bem.2250090407

Source DB:  PubMed          Journal:  Bioelectromagnetics        ISSN: 0197-8462            Impact factor:   2.010


  2 in total

Review 1.  The revised electromagnetic fields directive and worker exposure in environments with high magnetic flux densities.

Authors:  Rianne Stam
Journal:  Ann Occup Hyg       Date:  2014-02-20

Review 2.  A Source-based Measurement Database for Occupational Exposure Assessment of Electromagnetic Fields in the INTEROCC Study: A Literature Review Approach.

Authors:  Javier Vila; Joseph D Bowman; Lesley Richardson; Laurel Kincl; Dave L Conover; Dave McLean; Simon Mann; Paolo Vecchia; Martie van Tongeren; Elisabeth Cardis
Journal:  Ann Occup Hyg       Date:  2015-10-21
  2 in total