Literature DB >> 31903266

Multimodality cardiac computed tomography angiography and magnetic resonance with clinical-grade scanners provide robust assessment of cardiac morphology and function in rabbits.

Gitsios Gitsioudis1,2,3, Maximilian Nunninger1,2, Anna Missiou1,2,4, Peter Wolf1,2, Hugo A Katus1,2, Grigorios Korosoglou1,2.   

Abstract

BACKGROUND: Non-invasive computer tomography (CT)- and magnetic resonance (MR)-based cardiac imaging still remains challenging in rodents. To investigate the robustness of non-invasive multimodality cardiac imaging in rabbits using clinical-grade CT and MR scanners.
METHODS: A total of 16 rabbits (2.7-4.0 kg) serially underwent cardiac-gated imaging using a clinical-grade 256-row CT and a 1.5 Tesla MR-scanner at baseline and at 4-month follow-up (16±1 weeks). Image analysis included image quality (5-grade scale), left ventricular (LV) volumes, LV stroke volume, LV diameters, LV wall thickness and ejection fraction (LVEF).
RESULTS: Cardiac MR (CMR) and CT angiography (CTA) provide images with an overall good image quality (excellent or good quality: CMR 82% vs. CTA 78%, P=0.68). Linear regression analysis demonstrated a good correlation of all diameters (diam.) and volumes (vol.) as assessed by CTA and CMR (diam.: r=0.9, 95% CI: 0.8-0.9; vol.: r=0.8, 95% CI: 0.6-0.9; P<0.0001 for both). CTA-based volumetric analysis revealed slightly higher LVEF values as compared to CMR (CTA: 64%±1%, CMR: 59%±1%, P=0.002). Analysis of inter-/intra-observer agreement demonstrated excellent agreements for diameters (CMR: 98.5%/98.7%; CTA: 98.2%/97.4%) and volumes (CMR: 99.9%/98.8%; CTA 98.7%/98.7%). Finally, serial CMR- and CTA-based assessment of cardiac diameters and volumes delivered excellent intersession agreements of baseline versus follow-up data (diam.: CMR: r=0.89; CTA: r=0.92; vol.: CMR: r=0.87; CTA: r=0.96, P<0.0001 for all).
CONCLUSIONS: Multimodality non-invasive assessment of cardiac function and aortic hemodynamics is feasible and robust in rabbits using clinical-grade and MR and CT scanners. These imaging modalities could improve serial cardiac assessment for disease monitoring in preclinical settings. 2019 Journal of Thoracic Disease. All rights reserved.

Entities:  

Keywords:  Cardiac magnetic resonance (CMR); cardiac-gated computer tomography angiography (cardiac-gated CTA); rabbits; velocity-encoded phase contrast magnetic resonance imaging (velocity-encoded phase contrast MRI)

Year:  2019        PMID: 31903266      PMCID: PMC6940212          DOI: 10.21037/jtd.2019.10.46

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  37 in total

1.  A coupled experimental and computational approach to quantify deleterious hemodynamics, vascular alterations, and mechanisms of long-term morbidity in response to aortic coarctation.

Authors:  Arjun Menon; David C Wendell; Hongfeng Wang; Thomas J Eddinger; Jeffrey M Toth; Ronak J Dholakia; Paul M Larsen; Eric S Jensen; John F Ladisa
Journal:  J Pharmacol Toxicol Methods       Date:  2011-11-04       Impact factor: 1.950

Review 2.  Echocardiographic assessment of myocardial strain.

Authors:  John Gorcsan; Hidekazu Tanaka
Journal:  J Am Coll Cardiol       Date:  2011-09-27       Impact factor: 24.094

3.  Quantification of shunt volumes in congenital heart diseases using a breath-hold MR phase contrast technique--comparison with oximetry.

Authors:  Steffen E Petersen; Thomas Voigtländer; Karl-Friedrich Kreitner; Peter Kalden; Thomas Wittlinger; Jürgen Scharhag; Georg Horstick; Dietmar Becker; Gerhard Hommel; Manfred Thelen; Jürgen Meyer
Journal:  Int J Cardiovasc Imaging       Date:  2002-02       Impact factor: 2.357

4.  Severity of mitral and aortic regurgitation as assessed by cardiovascular magnetic resonance: optimizing correlation with Doppler echocardiography.

Authors:  Eli V Gelfand; Sean Hughes; Thomas H Hauser; Susan B Yeon; Lois Goepfert; Kraig V Kissinger; Neil M Rofsky; Warren J Manning
Journal:  J Cardiovasc Magn Reson       Date:  2006       Impact factor: 5.364

5.  Temporally resolved 3D phase-contrast imaging.

Authors:  L Wigström; L Sjöqvist; B Wranne
Journal:  Magn Reson Med       Date:  1996-11       Impact factor: 4.668

Review 6.  Echocardiographic evaluation of ventricular function in mice.

Authors:  Jeffrey N Rottman; Gemin Ni; Michael Brown
Journal:  Echocardiography       Date:  2007-01       Impact factor: 1.724

Review 7.  Flow quantification and analysis methods.

Authors:  N J Pelc
Journal:  Magn Reson Imaging Clin N Am       Date:  1995-08       Impact factor: 2.266

8.  Imaging time after Gd-DTPA injection is critical in using delayed enhancement to determine infarct size accurately with magnetic resonance imaging.

Authors:  J N Oshinski; Z Yang; J R Jones; J F Mata; B A French
Journal:  Circulation       Date:  2001-12-04       Impact factor: 29.690

9.  Accuracy of echocardiographic estimates of left ventricular mass in mice.

Authors:  K A Collins; C E Korcarz; S G Shroff; J E Bednarz; R C Fentzke; H Lin; J M Leiden; R M Lang
Journal:  Am J Physiol Heart Circ Physiol       Date:  2001-05       Impact factor: 4.733

10.  Time-resolved 3D MR velocity mapping at 3T: improved navigator-gated assessment of vascular anatomy and blood flow.

Authors:  Michael Markl; Andreas Harloff; Thorsten A Bley; Maxim Zaitsev; Bernd Jung; Ernst Weigang; Mathias Langer; Jürgen Hennig; Alex Frydrychowicz
Journal:  J Magn Reson Imaging       Date:  2007-04       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.