| Literature DB >> 31901124 |
Yi Tang1, Ming-Yu Wang2, Tao-Tao Wu1, Jian-Yu Zhang1, Ru Yang2, Bo Zhang3, Ying Shi1, Pin Meng1, Niu Ji3, Yongan Sun1, Ying-da Xu1, Bing-Chao Xu1, Xin-Yu Zhou1, Xiao-Bing He1, Guang-Hui Zhang1, Xiao-Qin Niu1, Zai-Po Li1, Bei Wang1, Bei Xu1, Zeng-Lin Cai1, Yong-Jin Zhang1, Ming-Li He4.
Abstract
INTRODUCTION: To improve the accuracy of ultrasound techniques for the assessment of carotid stenosis, we designed a novel carotid artery stenosis ultrasound scale (CASUS), and evaluated its accuracy, reliability, and its value in predicting the occurrence of cardiovascular and cerebrovascular diseases in a prospective study.Entities:
Keywords: Brain ischemic; Carotid stenosis; Cerebral blood flow; Neuroimaging; Ultrasound
Year: 2020 PMID: 31901124 PMCID: PMC7196942 DOI: 10.1007/s10072-019-04204-8
Source DB: PubMed Journal: Neurol Sci ISSN: 1590-1874 Impact factor: 3.307
Comparison of the predictive value of TSS, RI-TSS, and GBF for various endpoint events in ischemic stroke
| Endpoint events | Indexes | AUC | SE | 95% CI | BPP | P values |
|---|---|---|---|---|---|---|
| All-cause death | TSS | 0.753 | 0.030 | 0.696–0.811 | 10 | 0.167 |
| RI-TSS | 0.759 | 0.031 | 0.697–0.821 | 10 | ||
| GBF | 0.744 | 0.036 | 0.676–0.811 | – | ||
| Cardiovascular death | TSS | 0.791 | 0.046 | 0.701–0.880 | 10 | 0.126 |
| RI-TSS | 0.781 | 0.047 | 0.690–0.873 | 10 | ||
| GBF | 0.799 | 0.048 | 0.709–0.889 | – | ||
| Recurrent stroke | TSS | 0.718 | 0.029 | 0.661–0.775 | 7 | < 0.001 |
| RI-TSS | 0.713 | 0.029 | 0.657–0.770 | 8 | ||
| GBF | 0.721 | 0.030 | 0.662–0.780 | – | ||
| Non-fatal myocardial infarction | TSS | 0.756 | 0.031 | 0.695–0.817 | 9 | 0.072 |
| RI-TSS | 0.702 | 0.026 | 0.622–0.784 | 9 | ||
| GBF | 0.708 | 0.042 | 0.627–0.790 | – | ||
| Composite cardiovascular events | TSS | 0.761 | 0.019 | 0.719–0.803 | 10 | < 0.001 |
| RI-TSS | 0.753 | 0.021 | 0.711–0.794 | |||
| GBF | 0.754 | 0.021 | 0.710–0.798 | – |
TSS, total stenosis score; RI-TSS, radiologic image-total stenosis score; GBF, global blood flow; AUC, area under the curve; SE, standard error; BPP, best prediction point
Carotid artery blood flow and stenosis score calculation chart for stenosis of varying degrees
| Blood vessel | Index | No-stenosis BF | Mild-stenosis BF reduction | Moderate-stenosis BF reduction | Severe-stenosis BF reduction |
|---|---|---|---|---|---|
| ICA | BF, ml/Min | 418.4 ± 73.5 | 109.1 ± 76.3 | 189.4 ± 66.9 | 301.0 ± 63.8 |
| Calculated SS, point | 0 | 1 | 1.7 | 2.8 | |
| Approximate SS, point | 0 | 1 | 2 | 3 | |
| VA | BF, ml/Min | 172.2 ± 32.9 | 53.2 ± 31.9 | 86.5 ± 30.7 | 141.3 ± 28.5 |
| Calculated SS, point | 0 | 1 | 1.6 | 2.7 | |
| Approximate SS, point | 0 | 1 | 2 | 3 |
ICA, internal carotid artery; VA, vertebral artery; BF, blood flow; SS, stenosis score
Fig. 1The cubic simulation curve between TSS and GBF (a), and between RI-TSS and GBF (b)
Fig. 2The ROC curves of TSS for predicting clinical outcome in ischemic stroke. a All-cause death. b Cardiovascular death. c Recurrent stroke. d Complex cardiovascular events