Literature DB >> 31883628

Biomechanical effect of implant design on four implants supporting mandibular full-arch fixed dentures: In vitro test and finite element analysis.

Aaron Yu-Jen Wu1, Jui-Ting Hsu2, Lih-Jyh Fuh3, Heng-Li Huang4.   

Abstract

BACKGROUND/
PURPOSE: Impact of the implant shape on the biomechanical performance of all-on-four treatment of dental implant is still unclear. This study evaluated the all-on-four treatment with four osseointegrated implants in terms of the biomechanical effects of implant design and loading position on the implant and surrounding bone by using both in vitro strain gauge tests and three-dimensional (3D) finite element (FE) analyses.
METHODS: Both in vitro and 3D FE models were constructed with placing NobelSpeedy and NobelActive implants as well as a titanium framework in an edentulous jawbone based on the concept of all-on-four treatment. Three types of loads were applied: at the central incisor area (loading position 1) and at the molar regions with (loading position 2) and without (loading position 3) the denture cantilever. For the in vitro tests, the principal bone strains were recorded by rosette strain gauges and statistically evaluated using Wilcoxon's rank-sum test. The 3D FE simulations analyzed the peak von-Mises stresses in the implant and surrounding cortical bone.
RESULTS: The peak stress and strain in the surrounding bone were typically 36-62% (3D FE analysis) and 47-57% (in vitro test) (p < 0.001)higher for loading position 3 than for loading positions 1 and 2. Between those two implant designs, the bone strains and bone stresses did not differ significantly.
CONCLUSION: For all-on-four treatment with four osseointegrated dental implants, altering the implant design does not appear to affect the biomechanical performance of the entire treatment, especially in terms of the stresses and strains in the surrounding bone.
Copyright © 2019 Formosan Medical Association. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  All-on-four treatment with four osseointegrated dental implants; Finite element analysis; Implant design; In vitro strain gauge test; Loading position

Year:  2019        PMID: 31883628     DOI: 10.1016/j.jfma.2019.12.001

Source DB:  PubMed          Journal:  J Formos Med Assoc        ISSN: 0929-6646            Impact factor:   3.282


  7 in total

1.  Bone quality effect on short implants in the edentulous mandible: a finite element study.

Authors:  Chaowei Liu; Yifeng Xing; Yan Li; Yanjun Lin; Jianghan Xu; Dong Wu
Journal:  BMC Oral Health       Date:  2022-04-26       Impact factor: 3.747

2.  Biomechanical Evaluation of Bone Atrophy and Implant Length in Four Implants Supporting Mandibular Full-Arch-Fixed Dentures.

Authors:  Heng-Li Huang; Hui-Ling Tsai; Yu-Ling Wu; Jui-Ting Hsu; Aaron Yu-Jen Wu
Journal:  Materials (Basel)       Date:  2022-05-04       Impact factor: 3.748

3.  Comparative analysis of stress distribution in one-piece and two-piece implants with narrow and extra-narrow diameters: A finite element study.

Authors:  Fabricia Teixeira Barbosa; Luiz Carlos Silveira Zanatta; Edélcio de Souza Rendohl; Sergio Alexandre Gehrke
Journal:  PLoS One       Date:  2021-02-04       Impact factor: 3.240

4.  Selective Laser Melting and Electron Beam Melting of Ti6Al4V for Orthopedic Applications: A Comparative Study on the Applied Building Direction.

Authors:  Paola Ginestra; Rosalba Monica Ferraro; Keren Zohar-Hauber; Andrea Abeni; Silvia Giliani; Elisabetta Ceretti
Journal:  Materials (Basel)       Date:  2020-12-07       Impact factor: 3.623

5.  Analytical Modeling of the Interaction of a Four Implant-Supported Overdenture with Bone Tissue.

Authors:  Bohdan Pelekhan; Maciej Dutkiewicz; Ivan Shatskyi; Andrii Velychkovych; Mykola Rozhko; Liubomyr Pelekhan
Journal:  Materials (Basel)       Date:  2022-03-24       Impact factor: 3.623

6.  Effects of Stress on Osteoblast Proliferation and Differentiation Based on Endoplasmic Reticulum Stress and Wntβ-Catenin Signaling Pathway.

Authors:  Hanming Zhong; Xiaoyu Yang; Shitie Li; Xin Lei
Journal:  Contrast Media Mol Imaging       Date:  2022-09-19       Impact factor: 3.009

7.  Mechanical Response of PEKK and PEEK As Frameworks for Implant-Supported Full-Arch Fixed Dental Prosthesis: 3D Finite Element Analysis.

Authors:  Regina Furbino Villefort; Pedro Jacy Santos Diamantino; Sandra Lúcia Ventorin von Zeidler; Alexandre Luiz Souto Borges; Laís Regiane Silva-Concílio; Guilherme deSiqueira Ferreira Anzaloni Saavedra; João Paulo Mendes Tribst
Journal:  Eur J Dent       Date:  2021-09-24
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.