Literature DB >> 31879472

Tibio talar contact stress: An experimental and numerical study.

V Filardi1.   

Abstract

AIMS: Tibio-talar contact stress has been evaluated and successively compared by performing an ankle contact finite element (FE) analysis and an experimental test carried on an assembled simple synthetic model of ankle equipped with a high-resolution (Tekscan) pressure sensor.
METHODS: A numerical FEM analysis was carried out by simulating the ankle joint (foot, and tibia) in order to investigating the stress shielding on the contact surfaces. The foot was constrained at the base while a load of 980 N was applied on the top of the tibia. The same setup was experimentally reproduced by introducing a high-resolution (Tekscan) pressure sensor between tibia and foot.
RESULTS: Results evidenced a good agreement between numerical and experimental data, a percentage difference of 15% was evaluated on the equivalent Von Mises contact stress.
CONCLUSION: The obtained results reveal interesting consequences deriving by taking into account how the stress shielding can influence the integrity and resistance of bones. The methods used for this validation enable formal comparison of computational and experimental results, and open the way for objective statistical measures of regional correlation between FE-computed contact stress distributions from comparison articular joint surfaces.
© 2019 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  CAD; FE analysis; Stress on tibia; Tibio-talar contact

Year:  2019        PMID: 31879472      PMCID: PMC6919358          DOI: 10.1016/j.jor.2019.08.024

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  24 in total

1.  In vitro biomechanical evaluation of antegrade femoral nailing at early and late postoperative stages.

Authors:  Roberto Montanini; Vincenzo Filardi
Journal:  Med Eng Phys       Date:  2010-07-23       Impact factor: 2.242

2.  Stress shielding in the bony chain of leg in presence of varus or valgus knee.

Authors:  Vincenzo Filardi
Journal:  J Orthop       Date:  2014-07-17

3.  FE analysis of stress and displacements occurring in the bony chain of leg.

Authors:  Vincenzo Filardi
Journal:  J Orthop       Date:  2014-09-20

4.  Kinesiology of lower extremity bracing.

Authors:  J Perry
Journal:  Clin Orthop Relat Res       Date:  1974 Jul-Aug       Impact factor: 4.176

5.  Characterization of an innovative intramedullary nail for diaphyseal fractures of long bones.

Authors:  V Filardi
Journal:  Med Eng Phys       Date:  2017-09-01       Impact factor: 2.242

6.  Healing of femoral fractures by the meaning of an innovative intramedullary nail.

Authors:  V Filardi
Journal:  J Orthop       Date:  2018-01-17

Review 7.  Finite element analysis of sagittal balance in different morphotype: Forces and resulting strain in pelvis and spine.

Authors:  Vincenzo Filardi; Portaro Simona; Giorgio Cacciola; Salvatore Bertino; Luigi Soliera; Andrea Barbanera; Alessandro Pisani; Demetrio Milardi; Bramanti Alessia
Journal:  J Orthop       Date:  2017-03-25

8.  Analysis of foot position in ankle arthrodesis and its influence on gait.

Authors:  H A King; T B Watkins; K M Samuelson
Journal:  Foot Ankle       Date:  1980-07

9.  Load-bearing pattern of the ankle joint. Contact area and pressure distribution.

Authors:  M Kimizuka; H Kurosawa; T Fukubayashi
Journal:  Arch Orthop Trauma Surg       Date:  1980

10.  Flatfoot and normal foot a comparative analysis of the stress shielding.

Authors:  V Filardi
Journal:  J Orthop       Date:  2018-08-16
View more
  4 in total

1.  Statistical investigation about spinal clinical asymmetry in a school population.

Authors:  A Tisano; A Alito; D Milardi; R Fazio; L Virelli; C Zanella; C Ruggeri; V Filardi; D Bruschetta
Journal:  J Orthop       Date:  2020-08-18

2.  Traumatic and non-traumatic spinal cord injury: Demographic characteristics, neurological and functional outcomes. A 7-year single centre experience.

Authors:  B Alito; V Filardi; F Famà; D Bruschetta; C Ruggeri; G Basile; L Stancanelli; C D'Amico; S Bianconi; A Tisano
Journal:  J Orthop       Date:  2021-11-20

3.  Stress shielding analysis on easy step staple prosthesis for calcaneus fractures.

Authors:  V Filardi
Journal:  J Orthop       Date:  2019-09-12

4.  Hallux valgus (HV): A multi-approach investigation analysis.

Authors:  V Filardi
Journal:  J Orthop       Date:  2019-09-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.