Literature DB >> 20655271

In vitro biomechanical evaluation of antegrade femoral nailing at early and late postoperative stages.

Roberto Montanini1, Vincenzo Filardi.   

Abstract

The present study addresses the question of evaluating, by combining both experimental and numerical methods, the stress/strain distribution within a standardized composite femur implanted with an anterograde intramedullary nail. A transverse diaphyseal fracture has been introduced in order to evaluate the implant response in the early postoperative clinical stage. By comparing these experimental data with those obtained in the fully healed stage, in which the bone continuity had been recovered, it was possible to get information on load sharing between the bone and the intramedullary nail, location of high strain concentrations, bone relative motion at the fracture site, and stiffness reduction caused by bone discontinuity. Experimental data were correlated with those predicted by a validated 3D finite element model of the complete implant/femur assembly to investigate the full field stress distribution either in the cortical bone, in the nail or in the locking screws. The obtained results suggest that full weight bearing in the immediate post-operating stage should not be allowed since high stress levels are generated in the outer shell of the cortical bone either around the proximal screw hole or the upper locking screw hole. Long-term implant reliability should be guaranteed instead, since after fracture consolidation equivalent von Mises stresses never exceed critical levels neither in the bone nor in the implant.
Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20655271     DOI: 10.1016/j.medengphy.2010.06.005

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  14 in total

1.  FE analysis of stress and displacements occurring in the bony chain of leg.

Authors:  Vincenzo Filardi
Journal:  J Orthop       Date:  2014-09-20

2.  Experimental strain analysis on the entire bony leg compared with FE analysis.

Authors:  V Filardi; D Milardi
Journal:  J Orthop       Date:  2016-11-02

3.  Healing of tibial comminuted fractures by the meaning of an innovative intramedullary nail.

Authors:  V Filardi
Journal:  J Orthop       Date:  2019-02-28

4.  Healing of femoral fractures by the meaning of an innovative intramedullary nail.

Authors:  V Filardi
Journal:  J Orthop       Date:  2018-01-17

5.  Utilizing Multiple BioMEMS Sensors to Monitor Orthopaedic Strain and Predict Bone Fracture Healing.

Authors:  Jakob G Wolynski; Conor J Sutherland; Hilmi Volkan Demir; Emre Unal; Akbar Alipour; Christian M Puttlitz; Kirk C McGilvray
Journal:  J Orthop Res       Date:  2019-05-17       Impact factor: 3.494

6.  Finite element analysis of the foot: Stress and displacement shielding.

Authors:  V Filardi
Journal:  J Orthop       Date:  2018-09-06

7.  Tibio talar contact stress: An experimental and numerical study.

Authors:  V Filardi
Journal:  J Orthop       Date:  2019-08-14

8.  Stress distribution in the humerus during elevation of the arm and external abduction.

Authors:  V Filardi
Journal:  J Orthop       Date:  2020-02-04

9.  Stress shielding analysis on easy step staple prosthesis for calcaneus fractures.

Authors:  V Filardi
Journal:  J Orthop       Date:  2019-09-12

10.  Hallux valgus (HV): A multi-approach investigation analysis.

Authors:  V Filardi
Journal:  J Orthop       Date:  2019-09-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.