Biomechanical comparisons of spinal fracture models and the stabilizing effects of posterior instrumentations.

R L Ferguson1, A F Tencer, P Woodard, B L Allen.   

Abstract

In this study, the authors evaluated the stiffness of motion segments in intact spines in two spine fracture models, and with each of five implant systems used for posterior fixation of thoracolumbar spine fractures. The devices represented a cross-section of types, including those employing sublaminar wires with and without laminar hooks, pedicle screws, plates, and rods. Two spine fracture models, one partially and one totally destabilized, were used in the tests of the instrumentation. Stiffness, or the magnitude of load needed to produce a unit displacement of the construct in the direction of the applied load, was measured in flexion, extension, lateral bending, and torsion in combination with a compressive force. Both horizontal plane shear and angular displacements were measured in the two fracture patterns. All evaluations were made by testing the difference in stiffness for statistical significance among groups. The results showed significant differences in stiffness without instrumentation among intact spines, partly destabilized spines (anterior two-thirds of disk and posterior ligaments removed), and totally destabilized spines (only anterior longitudinal ligament intact). The implant/spine constructs were least stiff relative to the intact spine in torsion, followed in increasing order of stiffness with flexion, lateral bending, and extension. In the Roy-Camille plate with six-screw fixation was found to produce the stiffest construct, followed by wired Harrington rods, C-rods and J-rods, and the Vermont internal fixator.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3187690     DOI: 10.1097/00007632-198805000-00003

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  10 in total

1.  Visualizing the stress distribution within vascular tissues using intravascular ultrasound elastography: a preliminary investigation.

Authors:  Michael S Richards; Renato Perucchio; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2015-03-31       Impact factor: 2.998

2.  Two column lesions in the thoracolumbar junction: anterior, posterior or combined approach? A comparative biomechanical in vitro investigation.

Authors:  Tibor Bence; Ulrich Schreiber; Thomas Grupp; Erwin Steinhauser; Wolfram Mittelmeier
Journal:  Eur Spine J       Date:  2006-08-30       Impact factor: 3.134

3.  Biomechanical testing of three newly developed transpedicular multisegmental fixation systems.

Authors:  S Eggli; F Schläpfer; M Angst; P Witschger; M Aebi
Journal:  Eur Spine J       Date:  1992-09       Impact factor: 3.134

4.  Translaminar facet joint screws to enhance segmental fusion of the lumbar spine.

Authors:  D G Marchesi; N Boos; K Zuber; M Aebi
Journal:  Eur Spine J       Date:  1992-09       Impact factor: 3.134

Review 5.  Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws.

Authors:  Rajeev Verma; Sonal Krishan; Kurt Haendlmayer; A Mohsen
Journal:  Eur Spine J       Date:  2010-01-06       Impact factor: 3.134

Review 6.  Percutaneous interbody osteosynthesis in the treatment of thoracolumbar traumatic or tumoural lesions. A review of 51 cases.

Authors:  G Lozes; A Fawaz; P Mescola; T Marnay; M Herlant; P Devos; A Cama; G O Sertl; M Brambillas Bas; X Leclercq
Journal:  Acta Neurochir (Wien)       Date:  1990       Impact factor: 2.216

7.  Is a single anterolateral screw-plate fixation sufficient for the treatment of spinal fractures in the thoracolumbar junction? A biomechanical in vitro investigation.

Authors:  Ulrich Schreiber; Tibor Bence; Thomas Grupp; Erwin Steinhauser; Thomas Mückley; Wolfram Mittelmeier; Rudolf Beisse
Journal:  Eur Spine J       Date:  2004-07-09       Impact factor: 3.134

8.  Intraoperative 3-dimensional imaging (O-arm) for assessment of pedicle screw position: Does it prevent unacceptable screw placement?

Authors:  Jonathan N Sembrano; David W Polly; Charles Gerald T Ledonio; Edward Rainier G Santos
Journal:  Int J Spine Surg       Date:  2012-12-01

9.  Comparison of surgical outcomes in thoracolumbar fractures operated with posterior constructs having varying fixation length with selective anterior fusion.

Authors:  Hak Sun Kim; Seung Yup Lee; Ankur Nanda; Ju Young Kim; Jin Oh Park; Seong Hwan Moon; Hwan Mo Lee; Ho Joong Kim; Huan Wei; Eun Su Moon
Journal:  Yonsei Med J       Date:  2009-08-19       Impact factor: 2.759

10.  Computed Tomography-Based Feasibility Study of C1 Posterior Arch Crisscrossing Screw Fixation.

Authors:  Gururaj Sangondimath; Abhinandan Reddy Mallepally; Suman Salimath
Journal:  Asian Spine J       Date:  2020-01-08
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.