Literature DB >> 31874493

[3D printing non-coplanar template-assisted 125-iodine seed implantation for thorax movement tumor: individual template design method].

H T Sun1, Y L Jiang, Z Ji, F X Guo, R Peng, J H Fan, J J Wang.   

Abstract

Objective: To compare the dosimetric data between preoperative plans and postoperative verification in computed tomography CT-guided and 3D printing template-assisted 125-iodine ((125)I) seed implantation for thorax movement tumor and to explore the feasibility and accuracy of the individualized template design method.
Methods: A total of 35 patients, 20 males and 15 females with median age of 62 (17-87) years old, who registered from January 2016 to December 2017 applied with 3D printing guided template assisted radioactive seed implantations in Peking University Third Hospital were included in this study. (125)I seeds with a prescribed dose of 110-180 Gy were impanted. 3D printing templates were designed and produced for 35 cases. The dosimetric parameters: D(90), minimum peripheral dose (mPD), V(100), V(150), V(200), conformal index (CI), external index (EI), and homogeneity index (HI) were compared between pre-and post-plannings. Statistical method was two group of related non-parameters test.
Results: The design and production of 35 cases' templates were in place well. Compared with the preoperative planning, the postoperative D(90), V(100), V(150), V(200), mPD, CI, EI and HI differences were 5.57%, 0.34%, 0.33%, -1.20%, 21%, 2.8%, -14.2%, 4.71%, -10.4%. All the included dosimetry parameters changed slightly after surgery compared with before surgery, but the difference was not statistically significant(all P>0.05). Conclusions: The dosimetric parameters of postoperative verification are consistent well with the preoperative planning and have good accuracy, the results could meet the clinical requirements.

Entities:  

Keywords:  Radiotherapy dosage; Radiotherapy, computer-assisted; Thoracic neoplasms

Mesh:

Substances:

Year:  2019        PMID: 31874493     DOI: 10.3760/cma.j.issn.0376-2491.2019.47.005

Source DB:  PubMed          Journal:  Zhonghua Yi Xue Za Zhi        ISSN: 0376-2491


  2 in total

1.  The Accuracy of Individualized 3D-Printing Template-Assisted I125 Radioactive Seed Implantation for Recurrent/Metastatic Head and Neck Cancer.

Authors:  Bin Qiu; Yuliang Jiang; Zhe Ji; Haitao Sun; Jinghong Fan; Weiyan Li; Yuxia Shao; Ping Jiang; Junjie Wang
Journal:  Front Oncol       Date:  2021-03-31       Impact factor: 6.244

2.  The accuracy and dosimetric analysis of 3D-printing non-coplanar template-assisted iodine-125 seed implantation for recurrent chest wall cancer.

Authors:  Weijuan Jiang; Yi Chen; Zhe Ji; Yuliang Jiang; Bin Qiu; Haitao Sun; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2021-05-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.