Literature DB >> 3186793

Intertester reliability and concurrent validity of fluid-based and universal goniometers for active knee flexion.

W Rheault1, M Miller, P Nothnagel, J Straessle, D Urban.   

Abstract

This study was designed 1) to determine the intertester reliability of the universal goniometer and the fluid-based goniometer and 2) to establish the concurrent validity of the fluid-based goniometer. Two testers measured active knee flexion of 20 healthy subjects (15 women, 5 men) using both instruments. The subjects had a mean age of 24.8 years (s = 5.5) and reported no previous history of pathological conditions of the right lower extremity. Using a correlational design, high intertester reliability was established for each instrument (universal goniometer, r = .87; fluid-based goniometer, r = .83). The concurrent validity of the fluid-based goniometer was also good for both testers (tester A, r = .83; tester B, r = .82). When the data were subjected to t tests, significant differences were found between the instruments for each tester (p less than .05). The results suggest that similar measurements will be obtained between therapists using the universal and fluid-based goniometers; however, the two instruments cannot be used interchangeably in the clinic.

Entities:  

Mesh:

Year:  1988        PMID: 3186793     DOI: 10.1093/ptj/68.11.1676

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  9 in total

1.  Evidence for the therapeutic effect of the organic content in Szigetvár thermal water on osteoarthritis: a double-blind, randomized, controlled clinical trial.

Authors:  Adrienn Hanzel; Károly Berényi; Krisztina Horváth; Katalin Szendi; Balázs Németh; Csaba Varga
Journal:  Int J Biometeorol       Date:  2019-02-07       Impact factor: 3.787

2.  Cast versus splint in children with minimally angulated fractures of the distal radius: a randomized controlled trial.

Authors:  Kathy Boutis; Andrew Willan; Paul Babyn; Ron Goeree; Andrew Howard
Journal:  CMAJ       Date:  2010-09-07       Impact factor: 8.262

3.  Inter-rater and intra-rater reliability of the fluid goniometer for measuring active knee flexion in painful knees; correlations do not mean agreement.

Authors:  Wilton Remigio; Nancy Tsai; Leonivic Layos; Michelle Chavez
Journal:  J Phys Ther Sci       Date:  2017-06-07

4.  The office work and stretch training (OST) study: an individualized and standardized approach for reducing musculoskeletal disorders in office workers.

Authors:  Fabian Holzgreve; Laura Maltry; Jasmin Lampe; Helmut Schmidt; Andreas Bader; Julia Rey; David A Groneberg; Anke van Mark; Daniela Ohlendorf
Journal:  J Occup Med Toxicol       Date:  2018-12-17       Impact factor: 2.646

5.  The acute effect in performing common range of motion tests in healthy young adults: a prospective study.

Authors:  F Holzgreve; C Maurer-Grubinger; J Isaak; P Kokott; M Mörl-Kreitschmann; L Polte; A Solimann; L Wessler; N Filmann; A van Mark; L Maltry; D A Groneberg; D Ohlendorf
Journal:  Sci Rep       Date:  2020-12-10       Impact factor: 4.379

6.  Accuracy and reliability of a smartphone application for measuring the knee joint angle.

Authors:  Keisuke Ishii; Hiroyuki Oka; Yuji Honda; Daisuke Oguro; Youichiro Konno; Kousuke Kumeta; Shouta Nishihara; Hazuki Matsuyama; Ichiro Kaneko; Yasuo Takeuchi; Yoshinobu Watanabe; Hirotaka Kawano; Naoshi Ogata
Journal:  J Phys Ther Sci       Date:  2021-05-15

7.  Assessment set for evaluation of clinical outcomes in multiple sclerosis: psychometric properties.

Authors:  Kamila Rasova; Patricia Martinkova; Jana Vyskotova; Michaela Sedova
Journal:  Patient Relat Outcome Meas       Date:  2012-10-11

8.  The reliability of knee joint position testing using electrogoniometry.

Authors:  Pagamas Piriyaprasarth; Meg E Morris; Adele Winter; Andrea E Bialocerkowski
Journal:  BMC Musculoskelet Disord       Date:  2008-01-22       Impact factor: 2.362

9.  Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty.

Authors:  Anton F Lenssen; Ellen M van Dam; Yvonne H F Crijns; Mark Verhey; Ruud J T Geesink; Piet A van den Brandt; Rob A de Bie
Journal:  BMC Musculoskelet Disord       Date:  2007-08-17       Impact factor: 2.362

  9 in total