Literature DB >> 31858200

Leadless Micra Pacemaker Use in the Pediatric Population: Device Implantation and Short-Term Outcomes.

C R Breatnach1, L Dunne2, K Al-Alawi2, P Oslizlok2, D Kenny2, K P Walsh2.   

Abstract

The development of Leadless cardiac pacemakers avoids the inherent complications that may occur secondary to lead insertion. A large number of devices have been inserted in adult patients although data in pediatric patients are lacking. We aimed to assess our experience with the Leadless device in the pediatric population. We performed a retrospective study on all pediatric patients who underwent insertion of a Leadless pacemaker in our center. Data were collected for demographic, procedural, and outcome variables. Nine patients with a median (IQR) age and weight of 13 (12-14) years and 37 (31-50) kg, respectively, were enrolled. The median (IQR) procedural time was 62 (60-65) min with insertion thresholds of 0.5 (0.35-1) Volts at 0.24 ms. All devices were successfully inserted without complication. One device was replaced with a single-lead endocardial pacemaker at 1 year for increased thresholds. Leadless pacemaker device insertion is feasible in pediatric patients. Further studies and long-term follow-up are needed to ascertain device longevity and complication rates.

Entities:  

Mesh:

Year:  2019        PMID: 31858200     DOI: 10.1007/s00246-019-02277-y

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  4 in total

1.  Original Article--Outcomes of Pacing in Egyptian Pediatric Population.

Authors:  Ahmed Nabil Ali; Samir S Wafa; Hosni Hosni Arafa; Rania Samir
Journal:  J Saudi Heart Assoc       Date:  2021-04-15

2.  Delivery of a Leadless Transcatheter Pacing System as First-line Therapy in a 28-kg Pediatric Patient Through Proximal Right Internal Jugular Surgical Cutdown.

Authors:  Gretchen Hackett; Faisal Aziz; Soraya Samii; Jason R Imundo
Journal:  J Innov Card Rhythm Manag       Date:  2021-04-15

3.  Micra leadless pacemaker retrieval in a pediatric patient.

Authors:  Erick Jimenez; Varun Aggarwal; John Bass; Daniel Cortez
Journal:  Indian Pacing Electrophysiol J       Date:  2020-03-25

4.  2021 PACES expert consensus statement on the indications and management of cardiovascular implantable electronic devices in pediatric patients.

Authors:  Maully J Shah; Michael J Silka; Jennifer N Avari Silva; Seshadri Balaji; Cheyenne M Beach; Monica N Benjamin; Charles I Berul; Bryan Cannon; Frank Cecchin; Mitchell I Cohen; Aarti S Dalal; Brynn E Dechert; Anne Foster; Roman Gebauer; M Cecilia Gonzalez Corcia; Prince J Kannankeril; Peter P Karpawich; Jeffery J Kim; Mani Ram Krishna; Peter Kubuš; Martin J LaPage; Douglas Y Mah; Lindsey Malloy-Walton; Aya Miyazaki; Kara S Motonaga; Mary C Niu; Melissa Olen; Thomas Paul; Eric Rosenthal; Elizabeth V Saarel; Massimo Stefano Silvetti; Elizabeth A Stephenson; Reina B Tan; John Triedman; Nicholas H Von Bergen; Philip L Wackel
Journal:  Indian Pacing Electrophysiol J       Date:  2021-07-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.