Literature DB >> 3185134

Some factors that influence the steady state in steady-state free precession.

S Patz1.   

Abstract

Steady-state free precession (SSFP) and particularly the spatially periodic magnetization response with wavelength lambda that results in the presence of an applied gradient is discussed. The maximum SSFP magnetization does not always occur at the Larmor frequency but rather depends on both the phase cycling of the rf pulses and on the rf tip angle. The slow flow sensitivity of SSFP also depends on lambda. Experimental data of the flow sensitivity is shown to be parameterized by a dimensionless dephasing parameter phi defined as the ratio of the distance traveled by a spin in one cycle of the SSFP sequence as compared to lambda. An example of the creation of a moving reference frame with the SSFP sequence is given. The modulation in image intensity that results when the gradients are nearly but not exactly compensated and lambda becomes large (i.e., tens of pixels long) is demonstrated. The pixel length must be an integral number of lambda's in order to have a uniform image intensity from a uniform phantom.

Mesh:

Year:  1988        PMID: 3185134     DOI: 10.1016/0730-725x(88)90477-8

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  8 in total

1.  Interleaved balanced SSFP imaging: artifact reduction using gradient waveform grouping.

Authors:  Jon-Fredrik Nielsen; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2009-03       Impact factor: 4.813

2.  Analytical solution and verification of diffusion effect in SSFP.

Authors:  C E Carney; S T Wong; S Patz
Journal:  Magn Reson Med       Date:  1991-06       Impact factor: 4.668

3.  Improving contrast to noise ratio of resonance frequency contrast images (phase images) using balanced steady-state free precession.

Authors:  Jongho Lee; Masaki Fukunaga; Jeff H Duyn
Journal:  Neuroimage       Date:  2010-10-30       Impact factor: 6.556

4.  CSF flow studies of intracranial cysts and cyst-like lesions achieved using reversed fast imaging with steady-state precession MR sequences.

Authors:  K T Hoffmann; N Hosten; B U Meyer; S Röricht; C Sprung; J Oellinger; M Gutberlet; R Felix
Journal:  AJNR Am J Neuroradiol       Date:  2000-03       Impact factor: 3.825

5.  Simultaneous calculation of flow and diffusion sensitivity in steady-state free precession imaging.

Authors:  H Gudbjartsson; S Patz
Journal:  Magn Reson Med       Date:  1995-10       Impact factor: 4.668

6.  Reduction of flow artifacts by using partial saturation in RF-spoiled gradient-echo imaging.

Authors:  Misung Han; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-11       Impact factor: 4.668

7.  Pilot study of improved lesion characterization in breast MRI using a 3D radial balanced SSFP technique with isotropic resolution and efficient fat-water separation.

Authors:  Catherine J Moran; Frederick Kelcz; Youngkyoo Jung; Ethan K Brodsky; Sean B Fain; Walter F Block
Journal:  J Magn Reson Imaging       Date:  2009-07       Impact factor: 4.813

8.  3D Cartesian fast interrupted steady-state (FISS) imaging.

Authors:  Thomas Küstner; Aurélien Bustin; Olivier Jaubert; Radhouene Neji; Claudia Prieto; René Botnar
Journal:  Magn Reson Med       Date:  2019-06-14       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.