Literature DB >> 31838536

Overview of Different Flow Diverters and Flow Dynamics.

Georgios A Maragkos1, Adam A Dmytriw1,2, Mohamed M Salem1, Vincent M Tutino3, Hui Meng3, Christophe Cognard4, Paolo Machi5, Timo Krings2, Vitor Mendes Pereira2.   

Abstract

Over the past decade, flow diverter technology for endocranial aneurysms has seen rapid evolution, with the development of new devices quickly outpacing the clinical evidence base. However, flow diversion has not yet been directly compared to surgical aneurysm clipping or other endovascular procedures. The oldest and most well-studied device is the Pipeline Embolization Device (PED; Medtronic), recently transitioned to the Pipeline Flex (Medtronic), which still has sparse data regarding outcomes. To date, other flow diverting devices have not been shown to outperform the PED, although information comes primarily from retrospective studies with short follow-up, which are not always comparable. Because of this lack of high-quality outcome data, no reliable recommendations can be made for choosing among flow diversion devices yet. Moreover, the decision to proceed with flow diversion should be individualized to each patient. In this work, we wish to provide a comprehensive overview of the technical specifications of all flow diverter devices currently available, accompanied by a succinct description of the evidence base surrounding each device.
Copyright © 2019 by the Congress of Neurological Surgeons.

Entities:  

Keywords:  Cerebral aneurysm; Cerebrovascular disease/stroke; Embolization; Endovascular; Interventional neuroradiology

Year:  2020        PMID: 31838536     DOI: 10.1093/neuros/nyz323

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  5 in total

Review 1.  Shape Memory Polymer-Based Endovascular Devices: Design Criteria and Future Perspective.

Authors:  Sergio A Pineda-Castillo; Aryn M Stiles; Bradley N Bohnstedt; Hyowon Lee; Yingtao Liu; Chung-Hao Lee
Journal:  Polymers (Basel)       Date:  2022-06-21       Impact factor: 4.967

2.  Cavernous carotid artery large aneurysm treated with a new flow diverter - Xcalibur aneurysm occlusion device (AOD).

Authors:  Richa Singh Chauhan; Nihar Vijay Kathrani; Karthik Kulanthaivelu; Chandrajit Prasad; Arun Kumar Gupta
Journal:  Interv Neuroradiol       Date:  2020-08-18       Impact factor: 1.610

3.  WEB Device Shape Changes in Elastase-Induced Aneurysms in Rabbits.

Authors:  Y Ding; D Dai; A Rouchaud; K Janot; S Asnafi; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2020-12-10       Impact factor: 3.825

4.  Postinterventional Assessment after Stent and Flow-Diverter Implantation Using CT: Influence of Spectral Image Reconstructions and Different Device Types.

Authors:  C Zaeske; T Hickethier; J Borggrefe; L Goertz; R Dettmeyer; M Schlamann; N Abdullayev; C Kabbasch
Journal:  AJNR Am J Neuroradiol       Date:  2020-12-31       Impact factor: 3.825

5.  Preclinical safety and efficacy evaluation of the Pipeline Vantage Embolization Device with Shield Technology.

Authors:  Robert M Starke; John Thompson; Ariana Pagani; Animesh Choubey; John M Wainwright; Michael F Wolf; Reza Jahanbekam; Gaurav Girdhar
Journal:  J Neurointerv Surg       Date:  2020-06-02       Impact factor: 5.836

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.