A new sensitive spectrophotometric method for determination of saliva and blood glucose.

Parvin Mohammadnejad1, Saeed Soleimani Asl1, Saeed Aminzadeh1, Kamahldin Haghbeen2.   

Abstract

There is an increasing need for accurate and inexpensive glucometers as the world moves toward personalized medicine. Among the existing technologies, photometric based devices are more desired due to the cost-effectiveness, ease-of-use and the potential to be adopted in the smart-phone technology for remote sensing and self-monitoring purposes. However, the accuracy, precision, and reproducibility of the results of these devices are heavily dependent on the details of the chosen glucose measuring method. Considering the delicate problems with the current spectrophotometric methods, a new method was developed for more precise, accurate, and fast measurement of blood glucose via the coupled reactions of glucose oxidase and peroxidase using 4-[(4-Hydroxy-3-methoxyphenyl) azo]-benzenesulfonic acid (GASA) as the substrate. Stability of GASA and its oxidized products along with its direct and fast consumption by peroxidase, made it possible to determine blood glucose concentration in <20 s with high reproducibility. The low detection limit of GASA method (0.36 mg dL-1) with a linear range from 0.36 to 399.6 mg.dL-1 also allowed determination of salivary glucose concentration (SGC). As compared with the blood samples, the SGC results were more dispersed, especially for the diabetic participants, assumingly due to the diverse nature of salivary samples. However, a good correlation coefficient of 0.81 for non-diabetic individuals showed that it is accurate enough to recognize non-diabetic from diabetic condition. Results of this study disclose the potential application of GASA method as a reliable alternative for the current spectrophotometric methods with the ability to be adopted in miniaturized glucometers.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Diabetic; Glucose oxidase; Non-diabetic; Peroxidase; Photometric method

Year:  2019        PMID: 31836401     DOI: 10.1016/j.saa.2019.117897

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  4 in total

Review 1.  Technologies for Diabetes Self-Monitoring: A Scoping Review and Assessment Using the REASSURED Criteria.

Authors:  Jessica Hanae Zafra-Tanaka; David Beran; Beatrice Vetter; Rangarajan Sampath; Antonio Bernabe-Ortiz
Journal:  J Diabetes Sci Technol       Date:  2021-03-09

2.  New Provisional Function of OmpA from Acinetobacter sp. Strain SA01 Based on Environmental Challenges.

Authors:  Shahab Shahryari; Mahbubeh Talaee; Kamahldin Haghbeen; Lorenz Adrian; Hojatollah Vali; Hossein Shahbani Zahiri; Kambiz Akbari Noghabi
Journal:  mSystems       Date:  2021-01-12       Impact factor: 6.496

Review 3.  Enzymatic Methods for Salivary Biomarkers Detection: Overview and Current Challenges.

Authors:  Alonso Ornelas-González; Margarita Ortiz-Martínez; Mirna González-González; Marco Rito-Palomares
Journal:  Molecules       Date:  2021-11-20       Impact factor: 4.411

Review 4.  Glucose Oxidase, an Enzyme "Ferrari": Its Structure, Function, Production and Properties in the Light of Various Industrial and Biotechnological Applications.

Authors:  Jacob A Bauer; Monika Zámocká; Juraj Majtán; Vladena Bauerová-Hlinková
Journal:  Biomolecules       Date:  2022-03-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.