| Literature DB >> 31817396 |
Matthew Govorko1, Lin Fritschi1, Alison Reid1.
Abstract
Asbestos-containing materials (ACMs) were used extensively throughout much of the 20th century and can still be found in many Australian homes. Therefore, we developed a mobile application ("app"), called ACM Check, which guides users through a home inspection to identify and assess certain types of in situ ACM. A cross-sectional study was conducted using the app to collect data on the type and condition of in situ asbestos in Australian residential settings. Since being released in June 2017, we have received data for 702 home inspections. Of these, 578 (82.3%) houses contained a total of 1895 in situ materials categorised as positive for asbestos by the app. The most prevalent ACMs were used for the backing board to electrical meter boxes (50% of homes), eaves and soffit linings (44.2% of homes), and fencing (28.1% of homes). While the majority of ACMs were categorised as 'very low' or 'low' priority for removal or remediation, 6.6% of all ACMs were considered to be of 'high' priority. Mobile apps offer a platform to help increase people's awareness of possible health hazards found in the residential environment, such as asbestos, while also being used to collect data for public and environmental health research.Entities:
Keywords: asbestos; identification; mobile phone application; residential environment
Mesh:
Substances:
Year: 2019 PMID: 31817396 PMCID: PMC6950401 DOI: 10.3390/ijerph16244922
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Demographic information for users who completed ACM Check.
| Factor | Western Australia | Other | Total |
|---|---|---|---|
|
| |||
| Community member | 225 (67%) | 207 (56.6%) | 432 (61.5%) |
| Environmental health officer | 37 (11%) | 57 (15.6%) | 94 (13.4%) |
| Licensed asbestos removalist | 14 (4.2%) | 12 (3.3%) | 26 (3.7%) |
| Tradesperson, labourer, handyperson | 60 (17.9%) | 90 (24.6%) | 150 (21.4%) |
|
| |||
| Before 1985 | 223 (66.4%) | 270 (73.8%) | 493 (70.2%) |
| Between 1985 and 1990 | 55 (16.4%) | 60 (16.4%) | 115 (16.4%) |
| After 1990 | 58 (17.3%) | 36 (9.8%) | 94 (13.4%) |
|
| |||
| Separate house | 291 (86.6%) | 308 (84.2%) | 599 (85.3%) |
| Flat, unit or apartment | 22 (6.5%) | 32 (8.7%) | 54 (7.7%) |
| Semi-detached, row, villa, terrace house or townhouse | 23 (6.8%) | 26 (7.1%) | 49 (7%) |
|
| |||
| 0 1 | 25 (6.8%) | 27 (8%) | 52 (7.4%) |
| 1–2 | 145 (39.6%) | 134 (39.9%) | 279 (39.7%) |
| 3–4 | 141 (38.5%) | 130 (38.7%) | 271 (38.6%) |
| 5+ | 55 (15%) | 45 (13.4%) | 100 (14.2%) |
|
| 336 (100%) | 366 (100%) | 702 (100%) |
1 This includes houses that have no current occupants such as houses that are on the market or set for demolition.
Western Australian and other Australian state and territory houses with materials categorised as ‘positive’ for asbestos by ACM Check.
| Category | Western Australia (n = 336) | Other (n = 366) | Total (n = 702) |
|---|---|---|---|
|
| |||
| Exterior wall cladding | 54 (16.1%) | 72 (19.7%) | 126 (17.9%) |
| Eaves | 131 (39%) | 179 (48.9%) | 310 (44.2%) |
| Roof | 23 (6.8%) | 45 (12.3%) | 68 (9.7%) |
| Gutters | 6 (1.8%) | 18 (4.9%) | 24 (3.4%) |
| Downpipes | 31 (9.2%) | 57 (15.6%) | 88 (12.5%) |
| Backing board to electrical meter box | 183 (54.5%) | 168 (45.9%) | 351 (50%) |
| Fencing | 170 (50.6%) | 27 (7.4%) | 197 (28.1%) |
| Outbuilding walls | 27 (8%) | 55 (15%) | 82 (11.7%) |
| Outbuilding roof | 21 (6.3%) | 44 (12%) | 65 (9.3%) |
|
| |||
| Interior walls | 52 (5.5%) | 97 (26.5%) | 149 (21.2%) |
| Ceiling | 68 (20.2%) | 103 (28.1%) | 171 (24.4%) |
| Interior flooring | 65 (19.3%) | 122 (33.3%) | 187 (26.6%) |
| Heater flue | 24 (7.1%) | 53 (14.5%) | 77 (11%) |
|
| |||
| Any outside ACM 1 | 270 (80.4%) | 279 (76.2%) | 549 (78.2%) |
| Any inside ACM | 132 (39.3%) | 201 (54.9%) | 333 (47.4%) |
| Any ACM | 276 (82.1%) | 302 (82.5%) | 578 (82.3%) |
1 ACM: asbestos-containing material.
Priority levels of positive materials inspected in Western Australian houses (n = 336).
| Category | Very low | Low | Moderate | High | Total |
|---|---|---|---|---|---|
|
| |||||
| Exterior wall cladding | 21 (38.9%) | 15 (27.8%) | 17 (31.5%) | 1 (1.9%) | 54 |
| Eaves | 73 (55.7%) | 31 (23.7%) | 23 (17.6%) | 4 (3.1%) | 131 |
| Roof | 10 (43.5%) | 9 (39.1%) | 3 (13%) | 1 (4.3%) | 23 |
| Gutters | 3 (50%) | 1 (16.7%) | 2 (33.3%) | 0 | 6 |
| Downpipes | 22 (71%) | 6 (19.4%) | 3 (9.7%) | 0 | 31 |
| Backing board to electrical meter box | 136 (74.3%) | 23 (12.6%) | 21 (11.5%) | 3 (1.6%) | 183 |
| Fencing | 76 (44.7%) | 44 (25.9%) | 42 (24.7%) | 8 (4.7%) | 170 |
| Outbuilding walls | 10 (37%) | 8 (29.6%) | 9 (33.3%) | 0 | 27 |
| Outbuilding roof | 10 (47.6%) | 5 (23.8%) | 6 (28.6%) | 0 | 21 |
|
| |||||
| Interior walls | 25 (48.1%) | 14 (26.9%) | 13 (25%) | 0 | 52 |
| Ceiling | 39 (57.4%) | 16 (23.5%) | 10 (14.7%) | 3 (4.4%) | 68 |
| Interior flooring | 26 (40%) | 12 (18.5%) | 16 (24.6%) | 11 (16.9%) | 65 |
| Heater flue | 9 (37.5%) | 10 (41.7%) | 3 (12.5%) | 2 (8.3%) | 24 |
|
| |||||
| Outside ACMs 1 | 361 (55.9%) | 142 (22%) | 126 (19.5%) | 17 (2.6%) | 646 |
| Inside ACMs | 99 (47.4%) | 52 (24.9%) | 42 (20.1%) | 16 (7.7%) | 209 |
|
|
|
|
|
|
|
1 ACMs: asbestos-containing material.
Priority levels of positive materials inspected in other Australian state and territory houses (n = 366).
| Category | Very low | Low | Moderate | High | Total |
|---|---|---|---|---|---|
|
| |||||
| Exterior wall cladding | 32 (44.4%) | 15 (20.8%) | 20 (27.8%) | 5 (6.9%) | 72 |
| Eaves | 97 (54.2%) | 42 (23.5%) | 29 (16.2%) | 11 (6.1%) | 179 |
| Roof | 15 (33.3%) | 9 (20.0%) | 14 (31.1%) | 7 (15.6%) | 45 |
| Gutters | 2 (11.1%) | 3 (16.7%) | 9 (50.0%) | 4 (22.2%) | 18 |
| Downpipes | 28 (49.1%) | 15 (26.3%) | 11 (19.3%) | 3 (5.3%) | 57 |
| Backing board to electrical meter box | 105 (62.5%) | 34 (20.2%) | 25 (14.9%) | 4 (2.4%) | 168 |
| Fencing | 7 (25.9%) | 10 (37.0%) | 7 (25.9%) | 3 (11.1%) | 27 |
| Outbuilding walls | 19 (34.5%) | 15 (27.3%) | 16 (29.1%) | 5 (9.1%) | 55 |
| Outbuilding roof | 14 (31.8%) | 13 (29.5%) | 10 (22.7%) | 7 (15.9%) | 44 |
|
| |||||
| Interior walls | 32 (33.0%) | 26 (26.8%) | 27 (27.8%) | 12 (12.4%) | 97 |
| Ceiling | 48 (46.6%) | 28 (27.2%) | 21 (20.4%) | 6 (5.8%) | 103 |
| Interior flooring | 29 (23.8%) | 30 (24.6%) | 41 (33.6%) | 22 (18%) | 122 |
| Heater flue | 32 (60.4%) | 9 (17.0%) | 9 (17.0%) | 3 (5.7%) | 53 |
|
| |||||
| Outside ACMs 1 | 319 (48.0%) | 156 (23.5%) | 141 (21.2%) | 49 (7.4%) | 665 |
| Inside ACMs | 141 (37.6%) | 93 (24.8%) | 98 (26.1%) | 43 (11.5%) | 375 |
|
|
|
|
|
|
|
1 ACM: asbestos-containing material.