Literature DB >> 31816252

Effectiveness of miniscrew-supported maxillary incisor intrusion in deep-bite correction: A systematic review and meta-analysis.

Rami Sosly, Hisham Mohammed, Mumen Z Rizk, Eias Jamous, Ahmad G Qaisi, David R Bearn.   

Abstract

OBJECTIVES: To evaluate systematically the effectiveness of miniscrew-supported maxillary incisor intrusion compared with other nonsurgical intrusive mechanics for deep-bite correction.
MATERIALS AND METHODS: Unrestricted electronic searches in Embase, Web of Science, MEDLINE, LILACS, and Cochrane's CENTRAL as well as manual searches were conducted up to August 2019. Only randomized clinical trials (RCTs) were included. Study selection, data extraction, and bias assessment were done by two independent reviewers. The Cochrane risk-of-bias tool was used, and the quality of evidence was graded using the GRADE approach. A random-effects meta-analysis of continuous data, with its 95% confidence intervals (CIs), was used.
RESULTS: Seven RCTs were included in the quantitative synthesis, and the overall quality of evidence was very low to low. When compared with intrusion arches, miniscrews resulted in a more efficient deep-bite reduction with a standardized mean difference (SMD) of -0.48 (95% CI, -0.89 to -0.07). When miniscrews were used, a statistically significant difference was observed favoring less maxillary molar extrusion (SMD, -0.86; 95% CI, -1.46 to -0.27) and more incisor intrusion as measured from centroid to palatal plane (SMD, -0.95; 95% CI, -1.41 to -0.49). Results also showed a statistically nonsignificant difference regarding the amount of resultant root resorption between miniscrews and intrusion arches.
CONCLUSIONS: There is weak evidence indicating efficient deep-bite correction using miniscrews. Root resorption seems to be an associated adverse effect that occurs regardless of the intrusive mechanics used. These conclusions should be viewed with great caution as further well-designed long-term research is recommended.

Entities:  

Keywords:  Deep-bite malocclusion; Intrusion; Mini-implants; Miniscrews; Root resorption; Systematic review

Mesh:

Year:  2019        PMID: 31816252      PMCID: PMC8051239          DOI: 10.2319/061119-400.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  18 in total

1.  Treatment effects of intrusion arches and mini-implant systems in deepbite patients.

Authors:  Neslihan Ebru Senışık; Hakan Türkkahraman
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-06       Impact factor: 2.650

2.  Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement.

Authors:  David Moher; Alessandro Liberati; Jennifer Tetzlaff; Douglas G Altman
Journal:  Ann Intern Med       Date:  2009-07-20       Impact factor: 25.391

3.  GRADE: an emerging consensus on rating quality of evidence and strength of recommendations.

Authors:  Gordon H Guyatt; Andrew D Oxman; Gunn E Vist; Regina Kunz; Yngve Falck-Ytter; Pablo Alonso-Coello; Holger J Schünemann
Journal:  BMJ       Date:  2008-04-26

4.  Bias in meta-analysis detected by a simple, graphical test.

Authors:  M Egger; G Davey Smith; M Schneider; C Minder
Journal:  BMJ       Date:  1997-09-13

5.  RoB 2: a revised tool for assessing risk of bias in randomised trials.

Authors:  Jonathan A C Sterne; Jelena Savović; Matthew J Page; Roy G Elbers; Natalie S Blencowe; Isabelle Boutron; Christopher J Cates; Hung-Yuan Cheng; Mark S Corbett; Sandra M Eldridge; Jonathan R Emberson; Miguel A Hernán; Sally Hopewell; Asbjørn Hróbjartsson; Daniela R Junqueira; Peter Jüni; Jamie J Kirkham; Toby Lasserson; Tianjing Li; Alexandra McAleenan; Barnaby C Reeves; Sasha Shepperd; Ian Shrier; Lesley A Stewart; Kate Tilling; Ian R White; Penny F Whiting; Julian P T Higgins
Journal:  BMJ       Date:  2019-08-28

6.  Rate of intrusion of maxillary incisors in Class II Div 1 malocclusion using skeletal anchorage device and Connecticut intrusion arch.

Authors:  Prasanna Kumar; Sanjeev Datana; S M Londhe; Abhijeet Kadu
Journal:  Med J Armed Forces India       Date:  2015-12-31

7.  Effects of mandibular incisor intrusion obtained using a conventional utility arch vs bone anchorage.

Authors:  Esen Aydoğdu; Ömür Polat Özsoy
Journal:  Angle Orthod       Date:  2011-04-07       Impact factor: 2.079

8.  Comparison of the intrusion effects on the maxillary incisors between implant anchorage and J-hook headgear.

Authors:  Toru Deguchi; Takashi Murakami; Shingo Kuroda; Toshinori Yabuuchi; Hiroshi Kamioka; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-05       Impact factor: 2.650

Review 9.  Vertical malocclusions: etiology, development, diagnosis and some aspects of treatment.

Authors:  I L Nielsen
Journal:  Angle Orthod       Date:  1991       Impact factor: 2.079

Review 10.  Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis.

Authors:  Spyridon N Papageorgiou; Ioannis P Zogakis; Moschos A Papadopoulos
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-11       Impact factor: 2.650

View more
  4 in total

1.  Maxillary Incisor Intrusion Using Mini-Implants and Conventional Intrusion Arch: A Systematic Review and Meta-Analysis.

Authors:  Prateek Shakti; Abhinav Singh; Abhishek Purohit; Nidhi Shah
Journal:  Turk J Orthod       Date:  2022-06

Review 2.  Orthodontic Intrusion Using Temporary Anchorage Devices Compared to Other Orthodontic Intrusion Methods: A Systematic Review.

Authors:  Basma AlMaghlouth; Aqilah AlMubarak; Ibrahim Almaghlouth; Reem AlKhalifah; Amal Alsadah; Ali Hassan
Journal:  Clin Cosmet Investig Dent       Date:  2021-01-11

3.  Effect of Different Surface Designs on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study.

Authors:  Jin-Young Choi; Jaehee Cho; Song Hee Oh; Seong-Hun Kim; Kyu-Rhim Chung; Gerald Nelson
Journal:  Sensors (Basel)       Date:  2021-03-11       Impact factor: 3.576

4.  Evaluation of Optimal Sites for the Insertion of Orthodontic Mini Implants at Mandibular Symphysis Region through Cone-Beam Computed Tomography.

Authors:  Shizhen Zhang; Xiaoyu Wei; Lufei Wang; Zhouqiang Wu; Lu Liu; Xinyu Yan; Wenli Lai; Hu Long
Journal:  Diagnostics (Basel)       Date:  2022-01-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.