Literature DB >> 31810402

Retrospective Assessment of Endoscopic Enucleation of Prostate Complications: A Single-Center Experience of More Than 1400 Patients.

Andrey Morozov1, Mark Taratkin1, Vasiliy Kozlov2, Alexander Tarasov3, Evgeniy Bezrukov1, Mikhail Enikeev1, Andrew Shea Afyouni4, Zhamshid Okhunov1,4, Petr Glybochko1, Dmitry Enikeev1.   

Abstract

Introduction: Endoscopic enucleation of the prostate (EEP) is a safe method of treating benign prostatic hyperplasia, regardless of prostate volume and type of applied energy. To date, however, there has been no study that examines complication rates with respect to the type of applied energy. This study aims to address this problem by providing a retrospective analysis of >1400 patients who have undergone prostate enucleation. Materials and
Methods: We performed a retrospective analysis of all patients undergoing EEP between 2013 and 2018 at a single tertiary institution. This analysis included patients who had undergone one of three forms of EEP: holmium laser enucleation of the prostate (HoLEP), thulium fiber laser enucleation of the prostate (ThuFLEP), or monopolar enucleation of the prostate (MEP). We compared intraoperative and early postoperative complications, as well as complications at 3 and 6 months follow-up.
Results: A total of 1413 patients were included in this study; 36% patients underwent HoLEP, 57.5% had ThuFLEP, and 6.5% MEP. The most frequent complication in the early postoperative period was a mild fever (2.76% of the cases). The morcellation was delayed to a separate stage because of intensive hemorrhaging in 1.4% of the cases. Bladder tamponade was found in 1.1% of the cases. We found no correlation between complication rate and either prostate volume or energy source. Stress urinary incontinence was found in 3.9% of patients at 3 months and in only 1.4% of patients at 6 months after the operation. Urethral stricture at 6 months after the surgery was found in 1.4% of patients, whereas bladder neck sclerosis was found in only 0.9% of these cases. No significant difference was observed between these complication frequencies and any preoperative factors or energy source. Conclusions: All EEP types are safe with equal rates of complications intraoperatively, postoperatively, and at 6 months follow-up.

Entities:  

Keywords:  BPH; EEP; complications; monopolar endoscopic enucleation; thulium fiber laser

Mesh:

Substances:

Year:  2020        PMID: 31810402     DOI: 10.1089/end.2019.0630

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  7 in total

1.  Incidence and risk factors for postoperative urinary incontinence after various prostate enucleation procedures: systemic review and meta-analysis of PubMed literature from 2000 to 2021.

Authors:  Mohammad Hout; Aaron Gurayah; Maria Camila Suarez Arbelaez; Ruben Blachman-Braun; Khushi Shah; Thomas R W Herrmann; Hemendra N Shah
Journal:  World J Urol       Date:  2022-10-04       Impact factor: 3.661

2.  Randomized prospective trial of the severity of irritative symptoms after HoLEP vs ThuFLEP.

Authors:  Dmitry Enikeev; Mark Taratkin; Diana Babaevskaya; Andrey Morozov; Vladislav Petov; Roman Sukhanov; Evgeny Shpot; Vincent Misrai; Denis Chinenov; Mikhail Enikeev; Thomas Herrmann
Journal:  World J Urol       Date:  2022-06-12       Impact factor: 3.661

3.  T-L technique for HoLEP: perioperative outcomes of a large single-centre series.

Authors:  Angelo Porreca; Riccardo Schiavina; Daniele Romagnoli; Paolo Corsi; Antonio Salvaggio; Daniele D'Agostino; Matteo Ferro; Gian Maria Busetto; Roberto Falabella; Alessandro Crestani
Journal:  Cent European J Urol       Date:  2021-07-14

4.  Impact of perioperative factors on nadir serum prostate-specific antigen levels after holmium laser enucleation of prostate.

Authors:  Mary Martos; Jonathan E Katz; Madhumita Parmar; Anika Jain; Nachiketh Soodana-Prakash; Sanoj Punnen; Mark L Gonzalgo; Feng Miao; Isildinha M Reis; Nicholas Smith; Hemendra N Shah
Journal:  BJUI Compass       Date:  2021-01-05

Review 5.  A Systematic Review of Thulium Fiber Laser: Applications and Advantages of Laser Technology in the Field of Urology.

Authors:  Patrick Rice; Bhaskar K Somani
Journal:  Res Rep Urol       Date:  2021-07-22

Review 6.  Are all procedures for benign prostatic hyperplasia created equal? A systematic review on post-procedural PSA dynamics and its correlation with relief of bladder outlet obstruction.

Authors:  Abhishek Bhat; Ruben Blachman-Braun; Thomas R W Herrmann; Hemendra N Shah
Journal:  World J Urol       Date:  2021-07-02       Impact factor: 3.661

Review 7.  Ejaculations and Benign Prostatic Hyperplasia: An Impossible Compromise? A Comprehensive Review.

Authors:  Nicolas Couteau; Igor Duquesne; Panthier Frédéric; Nicolas Thiounn; Marc-Olivier Timsit; Arnaud Mejean; Ugo Pinar; François Audenet
Journal:  J Clin Med       Date:  2021-12-10       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.