Abstract
PURPOSE: To investigate the on-eye optical quality of a daily disposable silicone hydrogel contact lens with internal wetting agent. PATIENTS AND METHODS: Study subjects were daily disposable soft contact lens wearers (N=20) who were instructed to wear daily disposable hydrogel etafilcon A lens (without added wetting agent) or daily disposable silicone hydrogel senofilcon A lens (with an internal wetting agent), for a week. Subjects wore their respective lenses bilaterally and disposed of the pair of lenses daily. At the end of the 1-week test-wear period, the on-eye visual performances of the lens and the ocular surfaces were evaluated. A wavefront sensor measured sequential ocular higher-order aberrations (HOAs) for 10 s after the blink. The aberration data were analyzed in the central 4-mm diameter up to the sixth-order Zernike polynomials. Total HOAs, fluctuation index (FI), and stability index (SI) of the total HOAs over time were compared between the two lenses. Ocular surface evaluation with fluorescein was performed following the wavefront measurement.Entities:
Keywords: quantitative assessment; surface lens wettability; visual performance
Year: 2019 PMID: 31806929 PMCID: PMC6842293 DOI: 10.2147/OPTH.S224450
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Details Of Tested Contact Lenses
| Brand Name | 1-Day ACUVUE® | ACUVUE® OASYS® 1-Day With HydraLuxe™ Technology |
|---|---|---|
| Manufacturer | Johnson & Johnson Vision Care, Inc. | Johnson & Johnson Vision Care, Inc. |
| Material | Etafilcon A | Senofilcon A |
| Internal wetting agent | None | High molecular weight polyvinyl pyrrolidone |
| FDA classification | Group Ⅳ | Group I |
| Water content (%) | 58% | 38% |
| Base curve (mm) | 8.5/9.0 mm | 8.5/9.0 mm |
| Diameter (mm) | 14.2 mm | 14.3 mm |
| Center thickness (mm) | 0.07 mm (−3.00 D) | 0.085 mm (−3.00 D) |
| Method of manufacture | Stabilized soft molding | Stabilized soft molding |
Comparison Of Wavefront Data Between Etafilcon A Lens And Senofilcon A Lens
| Wavefront | Etafilcon A Lens | Senofilcon A Lens | P-value |
|---|---|---|---|
| Total HOAs (μm) | 0.168±0.049 | 0.131±0.044 | <0.001 |
| Fluctuation index of total HOAs | 0.034±0.034 | 0.013±0.008 | 0.001 |
| Stability index of total HOAs | 0.008±0.011 | 0.001±0.003 | 0.007 |
Abbreviation: HOA, higher-order aberrations.
Figure 1Sequential wavefront, color-coded maps of ocular higher-order aberrations with etafilcon A lens and senofilcon A lens in a 23-year-old woman. The simulated retinal images of a Landolt ring are shown.
Abbreviation: Total HOAs, total higher-order aberrations.