Literature DB >> 23510388

On-eye optical quality of daily disposable contact lenses for different wearing times.

Robert Montés-Micó1, Lurdes Belda-Salmerón, Teresa Ferrer-Blasco, César Albarrán-Diego, Santiago García-Lázaro.   

Abstract

PURPOSE: To quantify the optical quality of various daily disposable contact lenses in vivo and to ascertain its variation in terms of wearing time by means of objective non-invasive determination of wavefront patterns.
METHODS: The crx1 adaptive-optics system was used to measure the wavefront aberrations in 15 myopic eyes before and at 2-h intervals after contact lens fitting, over a 12-h wearing period. Seven types of contact lenses having different material, water content and lens design were evaluated in this study: Dailies Total1, Dailies AquaComfort Plus, Proclear 1 Day, 1-Day Acuvue TruEye, 1-Day Acuvue moist, SofLens daily disposable and Clariti 1-Day. The aberration data were analysed by fitting Zernike polynomials up to the 5th-order for 3 and 5-mm pupils. The optical quality under each condition and at each point in time was described by means of the Root-Mean-Square (RMS) value of wavefront aberration, Modulation Transfer Function (MTF), Point Spread Function and cut-off spatial frequency.
RESULTS: A RMS increase was observed after contact lens fitting as well as over time, both for a 3-mm and a 5-mm pupil. Each type of lens induced a different amount of wavefront aberrations, which vary over time also in a different manner. Dailies Total1 showed the lowest RMS values both at baseline and at the end of the day. In addition, Dailies Total1 provided the best MTF out of all the contact lenses that were assessed. These observations were reflected in higher cut-off spatial frequencies and visual resolution both at baseline and after 12 h of wearing time.
CONCLUSIONS: Aberrometry makes it possible to analyse accurately and in vivo the optical quality of contact lenses and to assess how lenses having different characteristics - such as material or water content - behave for different wearing times. These variations across contact lenses may result in differences in visual performance.
© 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

Entities:  

Keywords:  contact lenses; daily disposable; optical quality; visual performance

Mesh:

Year:  2013        PMID: 23510388     DOI: 10.1111/opo.12044

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  2 in total

1.  Objective Evaluation Of On-Eye Optical Quality Of Daily Disposable Silicone Hydrogel Contact Lens With Internal Wetting Agents.

Authors:  Shizuka Koh; Kiyoshi Watanabe; Kohji Nishida
Journal:  Clin Ophthalmol       Date:  2019-11-05

2.  Short-term tear film stability, optical quality and visual performance in two dual-focus contact lenses for myopia control with different optical designs.

Authors:  José Vicente García-Marqués; Rute Juliana Macedo-De-Araújo; Colm McAlinden; Miguel Faria-Ribeiro; Alejandro Cerviño; José Manuel González-Méijome
Journal:  Ophthalmic Physiol Opt       Date:  2022-07-08       Impact factor: 3.992

  2 in total