Literature DB >> 31792916

The additional prognostic value of myocardial perfusion SPECT in patients with known coronary artery disease with high exercise capacity.

Thais R Peclat1, Ana Carolina do A H de Souza2, Victor F Souza2, Aline M K Nakamoto2, Felipe M Neves2, Izabella C R Silva2, Ronaldo S L Lima2,3,4.   

Abstract

BACKGROUND: The prognostic value of myocardial perfusion imaging (MPI) in patients with known coronary artery disease (CAD) and high exercise capacity is still unknown. We sought to determine the MPI additional prognostic value over electrocardiography (ECG) stress testing alone in patients with known CAD who achieved ≥ 10 metabolic equivalents (METs). METHODS AND
RESULTS: We evaluated 926 patients with known CAD referred for MPI with exercise stress. Patients were followed for a mean of 32.4 ± 9.7 months for the occurrence of all-cause death or nonfatal myocardial infarction (MI). Those achieving ≥ 10 METs were younger, predominantly male, and had lower prevalence of cardiovascular risk factors. Patients reaching ≥ 10 METs had a lower annualized rate of hard events compared to their counterparts achieving < 10 METs (1.13%/year vs 3.95%/year, P < .001). Patients who achieved ≥ 10 METs with abnormal scans had a higher rate of hard events compared to those with normal scans (3.37%/year vs 0.57%/year, P = .023). Cardiac workload < 10 METs and an abnormal MPI scan were independent predictors of hard events.
CONCLUSIONS: MPI is able to stratify patients with known CAD achieving ≥ 10 METs for the occurrence of all-cause death and nonfatal MI, with incremental prognostic value over ECG stress test alone.
© 2019. American Society of Nuclear Cardiology.

Entities:  

Keywords:  CAD; ECG stress; METs; MPI; SPECT; exercise capacity; outcomes; prognostic

Mesh:

Year:  2019        PMID: 31792916     DOI: 10.1007/s12350-019-01960-0

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  1 in total

1.  Identification of the cohesion molecule, contact sites B, of Dictyostelium discoideum.

Authors:  C M Chadwick; D R Garrod
Journal:  J Cell Sci       Date:  1983-03       Impact factor: 5.285

  1 in total
  7 in total

1.  Optimizing patient centered care in the cardiac intensive care unit: Harness the safety, effectiveness, and incremental value of radionuclide perfusion, function, and molecular imaging.

Authors:  Peter A Bleszynski; Ronald G Schwartz
Journal:  J Nucl Cardiol       Date:  2021-06-24       Impact factor: 5.952

2.  Cardiac PET imaging: Lost in quantification. It's time to find the way.

Authors:  Emilia Zampella; Roberta Assante; Wanda Acampa; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2020-09-07       Impact factor: 5.952

3.  Myocardial blood flow reserve and absolute myocardial blood flow for the assessment of patients with coronary artery disease with or without microvascular dysfunction.

Authors:  Raffaele Giubbini; Elisabetta Cerudelli; Luca Camoni
Journal:  J Nucl Cardiol       Date:  2020-08-04       Impact factor: 5.952

4.  A big step towards clinical implementation of myocardial blood flow quantification with CZT SPECT.

Authors:  Matthieu Pelletier-Galarneau; Terrence D Ruddy
Journal:  J Nucl Cardiol       Date:  2019-09-18       Impact factor: 5.952

5.  Quantification of myocardial perfusion reserve by CZT-SPECT: A head to head comparison with 82Rubidium PET imaging.

Authors:  Wanda Acampa; Emilia Zampella; Roberta Assante; Andrea Genova; Giovanni De Simini; Teresa Mannarino; Adriana D'Antonio; Valeria Gaudieri; Carmela Nappi; Pietro Buongiorno; Ciro Gabriele Mainolfi; Mario Petretta; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2020-05-07       Impact factor: 5.952

6.  Diagnostic analysis of new quantitative parameters of low-dose dynamic myocardial perfusion imaging with CZT SPECT in the detection of suspected or known coronary artery disease.

Authors:  Zekun Pang; Jiao Wang; Shuai Li; Yue Chen; Xiaojie Wang; Jianming Li
Journal:  Int J Cardiovasc Imaging       Date:  2020-09-10       Impact factor: 2.357

7.  Impact of attenuation correction for CZT-SPECT measurement of myocardial blood flow.

Authors:  Matthieu Bailly; Frédérique Thibault; Maxime Courtehoux; Gilles Metrard; Maria Joao Ribeiro
Journal:  J Nucl Cardiol       Date:  2020-02-20       Impact factor: 5.952

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.