Literature DB >> 31785563

Evaluation of arsenic field test kits for drinking water: Recommendations for improvement and implications for arsenic affected regions such as Bangladesh.

Raghav R Reddy1, Grace D Rodriguez1, Tara M Webster2, Md Joynul Abedin3, Md Rezaul Karim3, Lutgarde Raskin1, Kim F Hayes4.   

Abstract

Arsenic field test kits are widely used to measure arsenic levels in drinking water sources, especially in countries like Bangladesh, where water supply is highly decentralized and water quality testing infrastructure is limited. From a public health perspective, the ability of a measurement technique to distinguish samples above and below relevant and actionable drinking water standards is paramount. In this study, the performance of eight commercially available field test kits was assessed by comparing kit estimates to hydride generation atomic absorption spectroscopy (HG-AAS) analyses. The results of tests that control for user-dependent color matching errors showed that two kits (LaMotte and Quick II kits) provided accurate and precise estimates of arsenic, four kits (Econo-Quick, Quick, Wagtech and Merck kits) were either accurate or precise, but not both, and two kits (Hach and Econo-Quick II kits) were neither accurate nor precise. Tests were performed for arsenic concentration ranges commonly found in natural waters and treated waters (such as community drinking water filter systems), and also on laboratory generated arsenic standards in DI water. For those kits that did not perform well, test strips often produced colors too light compared to manufacturer-provided arsenic color calibration charts. Based on these results, we recommend stakeholders carefully re-consider the use of poorly performing field test kits until better quality control of components of these kits is implemented. In addition, we recommend that field test kit manufacturers provide suitable internal standards in every kit box for users to verify the veracity of manufacturer provided color charts.
Copyright © 2019 The Authors. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Arsenic; Bangladesh; Color matching; Field kit; Test kit

Mesh:

Substances:

Year:  2019        PMID: 31785563     DOI: 10.1016/j.watres.2019.115325

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  5 in total

1.  Evaluation of a field kit for testing arsenic in paddy soil contaminated by irrigation water.

Authors:  Linden B Huhmann; Charles F Harvey; Jason Gross; Anjal Uddin; Imtiaz Choudhury; Kazi M Ahmed; John M Duxbury; Benjamin Bostick; Alexander van Geen
Journal:  Geoderma       Date:  2020-10-19       Impact factor: 6.114

Review 2.  Arsenic in the water and agricultural crop production system: Bangladesh perspectives.

Authors:  Arifin Sandhi; Changxun Yu; Md Marufur Rahman; Md Nurul Amin
Journal:  Environ Sci Pollut Res Int       Date:  2022-05-26       Impact factor: 5.190

3.  Well-Switching to Reduce Arsenic Exposure in Bangladesh: Making the Most of Inaccurate Field Kit Measurements.

Authors:  Yusuf Jameel; M Rajib Hassan Mozumder; Alexander van Geen; Charles F Harvey
Journal:  Geohealth       Date:  2021-12-01

4.  A Novel Computational Model for Detecting the Severity of Inflammation in Confirmed COVID-19 Patients Using Chest X-ray Images.

Authors:  Mohammed S Alqahtani; Mohamed Abbas; Ali Alqahtani; Mohammad Alshahrani; Abdulhadi Alkulib; Magbool Alelyani; Awad Almarhaby; Abdullah Alsabaani
Journal:  Diagnostics (Basel)       Date:  2021-05-10

5.  Low-cost electrochemical detection of arsenic in the groundwater of Guanajuato state, central Mexico using an open-source potentiostat.

Authors:  Jay C Bullen; Lawrence N Dworsky; Martijn Eikelboom; Matthieu Carriere; Alexandra Alvarez; Pascal Salaün
Journal:  PLoS One       Date:  2022-01-19       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.