Literature DB >> 3178212

Comparison of bacterial indicators and sampling programs for drinking water systems.

J F Collin1, D Zmirou, J P Ferley, M Charrel.   

Abstract

A total of 48 French villages were selected for a survey of water quality from February 1983 to June 1984 as part of an epidemiological study conducted in the rural area of the Rhône-Alpes region. Water samples were collected and analyzed on a weekly basis in each village. Bacteriological analysis of each water sample included enumeration of standard plate count bacteria, total and thermotolerant coliforms, and fecal streptococci. The water quality regulations are examined as to the analysis frequency, the volume of samples, and the relationship between the various bacterial indicators. Analyzing 300-ml, instead of 100-ml, samples tends to generate better information on single water samples. However, if many samples are analyzed over time from the same community, the value of using large volumes of water samples is diminished. The comparisons between bacterial indicators showed that the information obtained from the various indicators was very similar. However, fecal streptococci had a better predictive value of a negative test than coliforms with respect to the French standards.

Entities:  

Mesh:

Year:  1988        PMID: 3178212      PMCID: PMC202805          DOI: 10.1128/aem.54.8.2073-2077.1988

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  5 in total

1.  A follow-up study of gastro-intestinal diseases related to bacteriologically substandard drinking water.

Authors:  D Zmirou; J P Ferley; J F Collin; M Charrel; J Berlin
Journal:  Am J Public Health       Date:  1987-05       Impact factor: 9.308

2.  Frequency distribution of coliforms in water distribution systems.

Authors:  R R Christian; W O Pipes
Journal:  Appl Environ Microbiol       Date:  1983-02       Impact factor: 4.792

3.  Automation of water bacteriological analysis: running test of an experimental prototype.

Authors:  P A Trinel; N Hanoune; H Leclerc
Journal:  Appl Environ Microbiol       Date:  1980-05       Impact factor: 4.792

4.  Bacteriological analysis of water by potentiometric measurement of lipoic acid reduction: preliminary assays for selective detection of indicator organisms.

Authors:  G Charriere; T Jouenne; J F Lemeland; E Selegny; G A Junter
Journal:  Appl Environ Microbiol       Date:  1984-01       Impact factor: 4.792

5.  [Longitudinal study of the risks related to the consumption of water not conforming to bacteriological norms].

Authors:  J P Ferley; D Zmirou; J F Collin; M Charrel
Journal:  Rev Epidemiol Sante Publique       Date:  1986       Impact factor: 1.019

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.