Mohamed MesbahTahaHassanin1, Ahmad ShafieAmmar2, Radwa M Abdullah2, Mohammad Hassan Khedr2.
Abstract
BACKGROUND: Right ventricular apical pacing with the resultant left ventricular dyssynchrony often leads to depressed systolic function and heart failure. This study aimed at investigating the relation between various septal locations guided by ECG and fluoroscopy and the intermediate term functional capacity of the patients.Entities:
Keywords: 6 MWT; Different lead locations; Fluoroscopy; Pacing; QRS vector and duration
Year: 2019 PMID: 31782052 PMCID: PMC6883006 DOI: 10.1186/s43044-019-0023-1
Source DB: PubMed Journal: Egypt Heart J ISSN: 1110-2608
Fig. 1RAO view circles A and B show the approximate location of the septal lead in optimize RV and protect pace, respectively. Circle C shows the approximate location of the RV apical lead
Fig. 2LAO 40 view to differentiate lead placement on the RV septum from the RV free wall
Patients demographics
| Group 1 | Group 2 | Group 3 | ||
|---|---|---|---|---|
| Age | 63.5 ± 6.6 | 64.7 ± 7.5 | 68.8 ± 11.4 | 0.275 |
| HTN | 13 (86%) | 16 (64%) | 7 (70%) | 0.299 |
| DM | 5 (33%) | 11 (44%) | 4 (40%) | 0.801 |
| Smoking | 7 (46%) | 11 (44%) | 3 (30%) | 0.682 |
| Dyslipidemia | 3 (20%) | 4 (16%) | 2 (20%) | 0.934 |
| Female gender | 6 (40%) | 6 (24%) | 4 (40%) | 0.479 |
Demographic risk factors revealed no significant difference between the groups.
Differences in paced QRS duration according to septal pacing site in the three groups
| Paced QRS duration (ms) | ||
|---|---|---|
| Group 1 | 143.7 ± 10.4 | 0.675 |
| Group 2 | 143.9 ± 12.8 | |
| Group 3 | 147.7 ± 13.15 |
There is no significant difference found between the three groups of lead pacing site concerning the paced QRS duration
Comparison of paced QRS groups regarding vector in leads I and III toward the groups of pacing site
| Paced QRS vector configuration | ||||
|---|---|---|---|---|
| A ( | B ( | C ( | ||
| Group 1 | 8 (53%) | 4 (27%) | 3 (20%) | 0.045 |
| Group 2 | 9 (36%) | 10 (40%) | 6 (24%) | 0.057 |
| Group 3 | 2 (20%) | 1 (10%) | 7 (70%) | 0.02 |
Group 2 “mid septum” has no significant difference regarding the QRS vector configuration, but group 1 “high septum” has significant difference that 53% of them has QRS vector configuration as group A and group 3 “low septum” has significant difference that 70% of them has QRS vector configuration as group C
Comparison of paced QRS duration difference as regards the paced QRS vector groups in leads I and III
| Vector configuration | Paced QRS duration (ms) | |||
| Mean ± SD | ||||
| A | 136.5 | 9.4 | 0.001 | |
| B | 142.2 | 7.9 | ||
| C | 156.4 | 8.6 | ||
| Paced QRS vector groups “I” | “J” | Paced QRS duration (m) | ||
Mean difference “I–J” | Std error | |||
| Group A | B C | − 5.74035 − 19.91118* | 3.02522 2.97192 | 0.064 0.001 |
| Group B | A C | 5.74035 − 14.17083* | 3.02522 3.14786 | 0.064 0.001 |
| Group C | A B | 19.91118* 14.17083* | 2.97192 3.14786 | 0.001 0.001 |
According to the paced QRS vector groups and the QRS duration, there is no significant difference between groups A and B but there is markedly high significant difference between A and C and also between B and C which illuminates the result that groups A and B have significant shorter QRS duration than group C
Clinical functional capacity assessment through 6MWT results
6MWT in meters Mean ± SD | ||||
| Group 1 | 413.3 ± 148.5 | 0.04* | ||
| Group 2 | 359.8 ± 124.6 | |||
| Group 3 | 276.0 ± 98.5 | |||
| 6MWT (meters) | ||||
| Mean difference | SE | |||
| Group 1 | 2 | 53.453 | 41.780 | 0.207 |
| 3 | 137.333* | 52.225 | 0.012 | |
| Group 2 | 1 | − 53.453 | 41.780 | 0.207 |
| 3 | 83.880 | 47.865 | 0.086 | |
| Group 3 | 1 | − 137.333* | 52.225 | 0.012 |
| 2 | − 83.880 | 47.865 | 0.086 | |
According to the functional capacity clinical assessment, there is a significant difference that was found between the three groups confirmed by 6MWT
*The difference is highly significant between group 1 and group 3 in favor of group 1 (high septal location)