Literature DB >> 9973008

Optimal right ventricular pacing site in chronically implanted patients: a prospective randomized crossover comparison of apical and outflow tract pacing.

F Victor1, C Leclercq, P Mabo, D Pavin, A Deviller, C de Place, P Pezard, J Victor, C Daubert.   

Abstract

OBJECTIVES: To evaluate the long-term functional and hemodynamic effects of right ventricular outflow tract (RVOT) pacing by comparison with right ventricular apical (RVA) pacing.
BACKGROUND: Acute studies have suggested that RVOT pacing could significantly improve cardiac performance in comparison with RVA pacing but no data are available in chronically implanted patients.
METHODS: Sixteen patients with chronic atrial tachyarrhythmia and complete AV block were included. Left ventricular ejection fraction (LVEF) was > or =40% in ten and <40% in six. Patients were implanted with a standard DDDR pacemaker connected to two ventricular leads. A screw-in lead was placed at the RVOT and connected to the atrial port. A second lead was positioned at the RVA and connected to the ventricular port. Right ventricular outflow tract and RVA pacing was achieved by programming either the AAIR or the VVIR mode respectively. Four months later patients were randomized so as to undergo either RVOT or RVA pacing for three months according to a blind crossover protocol. Apart from the pacing mode, programming remained unchanged throughout the study. At the end of each period, NYHA class, LVEF, exercise time and maximal oxygen uptake were assessed.
RESULTS: No significant difference was observed between the two modes for all the parameters analyzed. These identical results were observed in all patients globally, in patients with LVEF > or =40% as in those with LVEF <40%.
CONCLUSIONS: Within the limits of this study, no symptomatic improvement or hemodynamic benefit was noted after three months of RVOT pacing, by comparison with RVA pacing.

Entities:  

Mesh:

Year:  1999        PMID: 9973008     DOI: 10.1016/s0735-1097(98)00589-0

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  31 in total

Review 1.  Permanent pacing: new indications.

Authors:  M R Gold
Journal:  Heart       Date:  2001-09       Impact factor: 5.994

Review 2.  Window to the heart: the value of a native and paced QRS duration. Current perspective and review.

Authors:  Himanshu H Shukla; Erskine A James; John A Schutz; Benjamin F Lloyd; Greg C Flaker
Journal:  J Interv Card Electrophysiol       Date:  2003-12       Impact factor: 1.900

Review 3.  Right ventricular pacing, mechanical dyssynchrony, and heart failure.

Authors:  Alan J Bank; Ryan M Gage; Kevin V Burns
Journal:  J Cardiovasc Transl Res       Date:  2011-12-22       Impact factor: 4.132

4.  Comparison of the acute hemodynamic effect of right ventricular apex, outflow tract, and dual-site right ventricular pacing.

Authors:  Andrzej Rubaj; Piotr Rucinski; Tomasz Sodolski; Andrzej Bilan; Marcin Gulaj; Alicja Dabrowska-Kugacka; Andrzej Kutarski
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-10       Impact factor: 1.468

Review 5.  Right ventricular outflow tract pacing: not ready for prime-time.

Authors:  S Serge Barold; Bengt Herweg
Journal:  J Interv Card Electrophysiol       Date:  2005-06       Impact factor: 1.900

6.  [16th part: ventricular lead position].

Authors:  C W Israel; D Pajitnev
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2007-09

Review 7.  [His-bundle stimulation and alternative RV stimulation sites].

Authors:  G Fröhlig; M Kindermann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-03

Review 8.  [Is resynchronization therapy necessary when optimizing right ventricular stimulation?].

Authors:  G Fröhlig
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-12

9.  How can we identify the optimal pacing site in the right ventricular septum? A simplified method applicable during the standard implanting procedure.

Authors:  Gianni Pastore; Francesco Zanon; Enrico Baracca; Gianluca Rigatelli; Giorgio Corbucci; Alberto Mazza; Franco Noventa; Loris Roncon
Journal:  Am J Cardiovasc Dis       Date:  2013-11-01

10.  Validating optimal function of the closed loop stimulation sensor with high right septal ventricular electrode placement in 'ablate and pace' patients.

Authors:  John Silberbauer; Paul S G Hong; Rick A Veasey; Nadeem A Maddekar; Wasing Taggu; Nikhil R Patel; Guy W Lloyd; Neil Sulke
Journal:  J Interv Card Electrophysiol       Date:  2009-07-23       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.