| Literature DB >> 31778431 |
Phelippe Augusto Valente Maia1, Victor Rodrigues Amaral Cossich1, José Inacio Salles-Neto1, Diego Pinheiro Aguiar1, Eduardo Branco de Sousa1.
Abstract
OBJECTIVES: This study aimed to evaluate the clinical outcomes of intra-articular infiltration with hyaluronic acid and dexamethasone alone and in combination in the treatment of knee osteoarthritis (OA).Entities:
Mesh:
Substances:
Year: 2019 PMID: 31778431 PMCID: PMC6844143 DOI: 10.6061/clinics/2019/e1207
Source DB: PubMed Journal: Clinics (Sao Paulo) ISSN: 1807-5932 Impact factor: 2.365
Figure 1Study flow diagram.
Demographic characteristics of patients included in the study. Demographic data of patients in each group.
| Demographic data | |||
|---|---|---|---|
| DX | VS | VD | |
| Patients (n, F:M) | 12 (11:1) | 16 (10:6) | 16 (10:6) |
| Laterality (R/L) | 9/3 | 10/6 | 7/9 |
| Height (m) | 156.7±1.98 | 1.63±3.2 | 165.6±2.2 |
| Weight (kg) | 76.8±3.9 | 86.5±4.9 | 79.3±3.2 |
| BMI (kg/m2) | 31.4±1.8 | 31.9±1.3 | 29.0±1.2 |
| Age (years) | 60.3±1.7 | 56.6±1.0 | 54.5±2.4 |
DX: dexamethasone; VS: viscosupplementation; VD: viscosupplementation plus dexamethasone, BMI: body mass index, F: female; M: male; R: right; L: left.
p<0.05 vs. DX group.
Figure 2WOMAC score evaluation. Significant effects were observed over time in the WOMAC total score and pain, stiffness and physical activity subscores (all, p<0.05). Additionally, significant effects between groups were observed in the pain (p=0.03), stiffness (p=0.03), and physical activity (p=0.03) subscores, but not in the WOMAC total score (p=0.07). Pairwise verification demonstrated differences between DX and VS. Further separate analysis revealed significant differences only within the VS group in terms of the pain (p=0.01), stiffness (p=0.04), and physical activity (p=0.05) subscores and the WOMAC total score (p=0.03). Symbols represent mean values, dashed and straight lines represent standard deviations. 6 W: six weeks, 3 M: three months and 6 M: six months; a: compared to PRE; b: compared to 6 W; c: compared to 3 M; d: compared to 6 M.
WOMAC questionnaire data. Data from the WOMAC questionnaire were divided into the score for three domains (pain, stiffness and function) and the total score for all three groups.
| Group | PRE | 6 W | 3 M | 6 M | F-value |
|
|
|---|---|---|---|---|---|---|---|
|
| |||||||
| VS | 15.3 (2.8) | 14.4 (3.5) | 14.3 (3.6) | 15.4 (2.6) | 5.09 |
| 0.39 |
| VD | 12.4 (4.9) | 9.9 (5.7) | 11.6 (5.9) | 11.7 (6.0) | 0.83 | 0.46 | 0.08 |
| DX | 12.8 (3.8) | 7.1 (3.8) | 7.1 (3.9) | 11.3 (6.2) | 0.14 | 0.93 | 0.02 |
|
| |||||||
| VS | 7.3 (3.2) | 5.5 (2.0) | 7.0 (3.1) | 6.3 (1.4) | 3.22 |
| 0.29 |
| VD | 4.6 (1.9) | 4.4 (2.7) | 5.6 (2.6) | 3.9 (2.6) | 0.15 | 0.15 | 0.18 |
| DX | 5.9 (1.1) | 3.4 (2.4) | 3.8 (2.6) | 3.7 (1.9) | 1.17 | 0.34 | 0.16 |
|
| |||||||
| VS | 52.4 (5.8) | 45.1 (11.0) | 49.3 (7.7) | 54.1 (11.4) | 3.90 |
| 0.34 |
| VD | 44.1 (14.8) | 35.7 (19.1) | 41.9 (20.5) | 37.0 (22.7) | 2.26 | 0.15 | 0.18 |
| DX | 42.4 (14.1) | 23.2 (13.3) | 26.1 (16.3) | 33.8 (21.5) | 1.17 | 0.34 | 0.16 |
|
| |||||||
| VS | 68.4 (18.3) | 59.4 (21.3) | 67.4 (15.9) | 73.5 (15.4) | 4.71 |
| 0.37 |
| VD | 61.1 (21.1) | 50.0 (27.2) | 59.0 (28.4) | 52.6 (31.1) | 1.04 | 0.34 | 0.09 |
| DX | 61.1 (16.9) | 33.8 (19.1) | 37.6 (23.1) | 48.8 (28.0) | 1.08 | 0.37 | 0.15 |
DX: dexamethasone; VS: viscosupplementation; VD: viscosupplementation + dexamethasone; PRE: before treatment; 6 W: six weeks after treatment; 3 M: three months after treatment; 6 M: 6 months after treatment. Values are shown as the mean (SD). Significant differences are in bold.
Figure 3Proprioception evaluation.A. Absolute error 20%. There were no significant differences regarding the AE20 over time (p=0.30) or between groups (p=0.20). B. Absolute error 50%. The same results were found for the AE50 over time (p=0.35). General analysis showed a significant difference between groups (p=0.036), which was not confirmed by pairwise comparison.
Figure 4Strength evaluation. A. Knee extensor peak torque. No significant differences regarding PT EXT over time (p=0.07) were identified. Analysis between groups presented significant differences (p=0.02). Pairwise differences were observed between DX and VD (p=0.027) and between DX and VS (p=0.043). B. Knee flexor peak torque. Regarding PT FLEX, significant main effects were observed both over time (p=0.01) and between groups (p=0.02). A pairwise significant difference was observed for DX and VD (p=0.034), but not for DX and VS (p=0.067). Further separate analysis revealed significant differences in both PT EXT (p=0.03) and PT FLEX (p=0.03) only in the VS group. Symbols represent mean values, dashed and straight lines represent standard deviations. 6 W: six weeks, 3 M: three months and 6 M: six months; a: compared to PRE; b: compared to 6 W; c: compared to 3 M; d: compared to 6 M.