Rachita Khot1, Melissa McGettigan2, James T Patrie3, Sebastian Feuerlein2. 1. Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States. 2. H Lee Moffitt Cancer Center and Research Institute, Tampa, 33612, United States. 3. Department of Public Health Sciences, University of Virginia, Charlottesville, VA, United States.
Abstract
OBJECTIVE: To test the hypothesis that there is a measureable upward motion of the diaphragm during prolonged breath-holds that could have a detrimental effect on image quality in liver MRI and to identify factor that potentially influence the magnitude of this motion. METHODS: 15 healthy volunteers underwent MRI examination using prolonged breath-holds in the maximum inspiratory position and a moderate inspiratory position. Coronal T1 weighted three-dimensional gradient echo sequences of the entire thorax were acquired every 6 s during breath-holding allowing the calculation of total lung volume and the measurement of the absolute position of the dome of the liver. The potential impact of subject's gender, body mass index, and total lung capacity on the change in lung volume/diaphragmatic motion was assessed using random coefficient regression. RESULTS: All volunteers demonstrated a slow reduction of the total lung volume during prolonged breath-holding up to 123 ml. There was a measurable associated upward shift of the diaphragm, measuring up to 5.6 mm after 24 s. There was a positive correlation with female gender (p = 0.037) and total lung volume (p = 0.005) and a negative association with BMI (p = 0.012) for the maximum inspiratory position only. CONCLUSION: There is a measureable reduction of lung volumes with consecutive upward shift of the diaphragm during prolonged breath-holding which likely contributes to motion artifacts in liver MRI. ADVANCES IN KNOWLEDGE: There is a measureable gas exchange-related reduction of lung volumes with consecutive upward shift of the diaphragm during prolonged breath-holding which likely contributes to motion artifacts in liver MRI. Correcting for this predictable upward shift has potential to improve image quality.The magnitude of this effect does not seem to be related to gender, BMI or total lung capacity if a moderate inspiratory position is used.
OBJECTIVE: To test the hypothesis that there is a measureable upward motion of the diaphragm during prolonged breath-holds that could have a detrimental effect on image quality in liver MRI and to identify factor that potentially influence the magnitude of this motion. METHODS: 15 healthy volunteers underwent MRI examination using prolonged breath-holds in the maximum inspiratory position and a moderate inspiratory position. Coronal T1 weighted three-dimensional gradient echo sequences of the entire thorax were acquired every 6 s during breath-holding allowing the calculation of total lung volume and the measurement of the absolute position of the dome of the liver. The potential impact of subject's gender, body mass index, and total lung capacity on the change in lung volume/diaphragmatic motion was assessed using random coefficient regression. RESULTS: All volunteers demonstrated a slow reduction of the total lung volume during prolonged breath-holding up to 123 ml. There was a measurable associated upward shift of the diaphragm, measuring up to 5.6 mm after 24 s. There was a positive correlation with female gender (p = 0.037) and total lung volume (p = 0.005) and a negative association with BMI (p = 0.012) for the maximum inspiratory position only. CONCLUSION: There is a measureable reduction of lung volumes with consecutive upward shift of the diaphragm during prolonged breath-holding which likely contributes to motion artifacts in liver MRI. ADVANCES IN KNOWLEDGE: There is a measureable gas exchange-related reduction of lung volumes with consecutive upward shift of the diaphragm during prolonged breath-holding which likely contributes to motion artifacts in liver MRI. Correcting for this predictable upward shift has potential to improve image quality.The magnitude of this effect does not seem to be related to gender, BMI or total lung capacity if a moderate inspiratory position is used.
Authors: Sebastian Feuerlein; Oliver Klass; Alberto Pasquarelli; Hans-Juergen Brambs; Arthur Wunderlich; Jeffrey L Duerk; Andrik J Aschoff; Martin H K Hoffmann Journal: Acad Radiol Date: 2009-03 Impact factor: 3.173
Authors: Nicholas J Tustison; Philip A Cook; Arno Klein; Gang Song; Sandhitsu R Das; Jeffrey T Duda; Benjamin M Kandel; Niels van Strien; James R Stone; James C Gee; Brian B Avants Journal: Neuroimage Date: 2014-05-29 Impact factor: 6.556
Authors: Temel Tirkes; Kumaresan Sandrasegaran; Rupan Sanyal; Stuart Sherman; C Max Schmidt; Gregory A Cote; Fatih Akisik Journal: Radiographics Date: 2013 Nov-Dec Impact factor: 5.333
Authors: Michael Parkes; Jason Cashmore; Stuart Green; Thomas Clutton-Brock; Irma Van Dijk; Zdenko van Kesteren; Geertjan van Tienhoven; Arjan Bel; Joost van den Aardweg; Markus Stevens Journal: Br J Radiol Date: 2020-06-02 Impact factor: 3.039