Literature DB >> 31778024

Long-term outcome of percutaneous intervention for pulmonary vein stenosis after pulmonary vein isolation procedure.

Patcharapong Suntharos1,2, Sarah E Worley3, Wei Liu3, Marion Siperstein2, Lourdes R Prieto1.   

Abstract

OBJECTIVES: Report long-term outcomes of percutaneous intervention in patients with pulmonary vein stenosis (PVS) after pulmonary vein isolation (PVI) from a single center over 16 years.
BACKGROUND: Outcome reports of percutaneous intervention for PVS resulting from PVI are limited.
METHODS: Retrospective review of all patients with PVS after PVI who underwent percutaneous intervention at the Cleveland Clinic Foundation between January 2000 and December 2016.
RESULTS: A total of 205 patients underwent cardiac catheterization for PVS during the study period. Completely occluded veins which could not be recanalized occurred in six patients. Of the remaining 199 patients, 27 (14%) were lost to follow-up, leaving 172 patients with 276 veins for analysis. Balloon angioplasty was performed in 62 veins and stent implantation in 250 (primary in 214, to treat postdilation restenosis in 36). Re-intervention occurred in 45/62 (73%) balloon-dilated veins and 45/250 (18%) stented veins. Freedom from re-intervention at 1 and 5 years was 90 and 73% following stenting versus 40 and 23% following balloon dilation (p < .001, Hazard ratio (HR) = 5.7). Veins with stent diameter ≥7 mm (n = 231) had greater freedom from re-intervention (95% at 1 year, 79% at 5 years) than veins with stents <7 mm (43% at 1 year, 9% at 5 years), p < .001. There was clear symptomatic improvement after intervention and no procedural mortality.
CONCLUSIONS: Stent implantation at ≥7 mm for PVS after PVI is associated with low rates of re-intervention, in contrast to balloon dilation and stenting with small conventional stents.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  pulmonary vein intervention; pulmonary vein isolation; pulmonary vein stenosis

Mesh:

Year:  2019        PMID: 31778024     DOI: 10.1002/ccd.28628

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  1 in total

1.  Intravascular ultrasound-guided drug-coated balloon venoplasty for in-stent restenosis in pulmonary veins stenosis: a case report.

Authors:  Juan J Portero-Portaz; Juan G Córdoba-Soriano; Arsenio Gallardo-López; Jesús M Jiménez-Mazuecos
Journal:  Eur Heart J Case Rep       Date:  2021-11-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.