| Literature DB >> 31766137 |
Naudia Gray1, Mary Halstead2, Nathalie Gonzalez-Jimenez1, Liza Valentin-Blasini1, Clifford Watson1, R Steven Pappas1.
Abstract
As the technology of electronic nicotine delivery systems (ENDS), including e-cigarettes, evolves, assessing metal concentrations in liquids among brands over time becomes challenging. A method for quantification of chromium, nickel, copper, zinc, cadmium, tin, and lead in ENDS liquids using triple quadrupole inductively coupled plasma mass spectrometry was developed. The method's limits of detection (LODs) were 0.031, 0.032, 3.15, 1.27, 0.108, 0.099, 0.066 µg/g for Cr, Ni, Cu, Zn, Cd, Sn, and Pb respectively. Liquids analyzed were from different brands and flavors of refill bottles or single-use, rechargeable, and pod devices from different years. Scanning electron microscopy with energy dispersive spectroscopy further evaluated the device components' compositions. Refill liquids before contacting a device were below lowest reportable levels (LRL) for all metals. Copper and zinc were elevated in liquids from devices containing brass. Cadmium was <LRL in all liquids and was not observed in device components. Cr, Ni, Cu, Zn, Sn, and Pb, reported in µg/g, ranged from <LRL to 0.396, 4.04, 903, 454, 0.898, and 13.5 respectively. Elevated metal concentrations in the liquid were also elevated in aerosol from the corresponding device. The data demonstrates the impact of device design and materials on toxic metals in ENDS liquid.Entities:
Keywords: ENDS; e-cigarettes; e-liquid; electronic cigarettes; inorganic; metals; vapes; vaping
Mesh:
Substances:
Year: 2019 PMID: 31766137 PMCID: PMC6888324 DOI: 10.3390/ijerph16224450
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Method precision using 20 duplicate runs of quality controls (QCs).
| Precision (%RSD) ( | ||||
|---|---|---|---|---|
| Analyte | QC Sample | Mean | Repeatability (%) | Intermediate Precision (%) |
|
| Low Spike | 2.02 | 3.70 | 2.03 |
| High Spike | 15.1 | 2.58 | 2.04 | |
|
| Low Spike | 2.03 | 4.16 | 2.34 |
| High Spike | 14.7 | 1.47 | 1.16 | |
|
| Low Spike | 204 | 1.33 | 0.814 |
| High Spike | 1500 | 1.24 | 0.912 | |
|
| Low Spike | 101 | 2.22 | 1.32 |
| High Spike | 764 | 2.07 | 0.902 | |
|
| Low Spike | 10.0 | 1.86 | 0.953 |
| High Spike | 75 | 1.46 | 0.797 | |
|
| Low Spike | 10.1 | 1.62 | 0.875 |
| High Spike | 74.8 | 1.16 | 0.737 | |
|
| Low Spike | 9.98 | 1.38 | 0.841 |
| High Spike | 76.4 | 1.58 | 1.13 | |
ENDS Liquid Instrument Modes and Internal Standard Assignments.
| Element Isotope | Instrument Mode | Cell Gas | Quantitated Ion | Quantitated Mass | Internal Standard |
|---|---|---|---|---|---|
| 52Cr | MS-MS | NH3 | 52Cr(NH3)2+ | 86 | 103Rh(NH3)4+ |
| 60Ni | MS-MS | O2 | 60NiO+ | 76 | 103RhO+ |
| 63Cu | MS-MS | He | 63Cu+ | 63 | 103Rh+ |
| 68Zn | MS-MS | He | 68Zn+ | 68 | 103Rh+ |
| 111Cd | MS-MS | O2 | 111Cd+ | 111 | 103RhO+ |
| 118Sn | MS-MS | He | 118Sn+ | 118 | 103Rh+ |
| 206+207+208Pb | MS-MS | He | 206,207,208Pb+ | 206 + 207 + 208 | 193Ir+ |
Cell parameters for modes: 0.5 mL/min O2 cell gas with −20 V octopole bias, −8 V energy discrimination; 4 mL/min 10% NH3, 90% He cell gas with −18 V octopole bias, −8 V energy discrimination; 5 mL/min He cell gas with −18 V octopole bias, 3 V energy discrimination.
Figure 1SEM image with EDS elemental mapping of a representative brass connector. Silicon- and oxygen-containing fibers are from the device wick.
Limits of detection and lowest calibration standard.
| Cr | Ni | Cu | Zn | Cd | Sn | Pb | |
|---|---|---|---|---|---|---|---|
|
| 0.031 | 0.032 | 3.15 | 1.27 | 0.108 | 0.099 | 0.066 |
|
| 0.025 | 0.025 | 2.00 | 1.00 | 0.100 | 0.100 | 0.100 |
Metal concentrations in electronic nicotine delivery systems (ENDS) liquids from JUUL pods obtained in 2018 (mean ± standard deviation, µg/g).
| JUUL® | Cr | Ni | Cu | Zn | Cd | Sn | Pb |
|---|---|---|---|---|---|---|---|
|
| <LRL | 0.040 ± 0.009 | <LRL | <LRL | <LRL | <LRL | <LRL |
|
| <LRL | <LRL | <LRL | <LRL | <LRL | <LRL | <LRL |
|
| <LRL | 0.057 ± 0.008 | <LRL | <LRL | <LRL | <LRL | <LRL |
|
| <LRL | 0.091 ± 0.022 | <LRL | <LRL | <LRL | <LRL | <LRL |
Metal concentrations from devices without brass connectors that were manufactured and analyzed in different years. Vuse devices are cartridges with rechargeable batteries, and NJOY devices are single-use (mean ± standard deviation, µg/g).
| Brand | Cr | Ni | Cu | Zn | Cd | Sn | Pb |
|---|---|---|---|---|---|---|---|
|
| 0.396 ± 0.138 | 0.642 ± 0.078 | <LRL | <LRL | <LRL | <LRL | <LRL |
|
| 0.300 ± 0.049 | 0.409 ± 0.080 | <LRL | <LRL | <LRL | <LRL | <LRL |
|
| 0.243 ± 0.040 | 0.478 ± 0.045 | <LRL | <LRL | <LRL | <LRL | <LRL |
|
| 0.057 ± 0.027 | 0.387 ± 0.114 | <LRL | <LRL | <LRL | <LRL | <LRL |
|
| <LRL | 0.148 ± 0.026 | <LRL | <LRL | <LRL | 0.355 ± 0.087 | <LRL |
|
| <LRL | 0.188 ± 0.015 | <LRL | <LRL | <LRL | 0.119 ± 0.018 | <LRL |
Metal concentrations comparing brands with design changes. The older devices were analyzed two years after acquisition (mean ± standard deviation, µg/g).
| Brand | Cr | Ni | Cu | Zn | Cd | Sn | Pb |
|---|---|---|---|---|---|---|---|
|
| 0.231 ± 0.018 | 4.04 ± 0.10 | 176 ± 6 | 3.00 ± 0.20 | <LRL * | 0.239 ± 0.010 | <LRL |
|
| <LRL | 0.050 ± 0.006 | 29.4 ± 3.2 | 9.32 ± 2.25 | <LRL | <LRL | <LRL |
|
| <LRL | 2.59 ± 0.22 | 903 ± 27 | 454 ± 11 | <LRL | 0.898 ± 0.054 | 13.5 ± 0.4 |
|
| <LRL | 0.731 ± 0.223 | 418 ± 58 | 140 ± 47 | <LRL | 0.216 ± 0.021 | 1.66 ± 0.93 |
* Duplicate results.
Metal concentrations from 21st Century cartridges comparing older and newer samples (mean ± standard deviation, µg/g).
| 21st Century® | Cr | Ni | Cu | Zn | Cd | Sn | Pb |
|---|---|---|---|---|---|---|---|
|
| <LRL | 0.755 ± 0.318 | 319 ± 13 | 113 ± 2 | <LRL | 0.365 ± 0.142 | 1.35 ± 0.28 |
|
| <LRL | 0.363 ± 0.513 | <LRL | <LRL | <LRL | <LRL | <LRL |
|
| <LRL | 0.427 ± 0.058 | 205 ± 6 | 64.6 ± 1.9 | <LRL | 0.208 ± 0.164 | <LRL |
|
| 0.033 ± 0.016 | 0.211 ± 0.068 | <LRL | <LRL | <LRL | <LRL | <LRL |
|
| <LRL | 0.452 ± 0.103 | 9.18 ± 0.73 | 12.5 ± 0.7 | <LRL | <LRL | 0.668 ± 0.015 |
|
| <LRL | 0.746 ± 0.342 | <LRL | 13.5 ± 0.3 | <LRL | 0.262 ± 0.210 | 0.691 ± 0.020 |
§ Brass connectors were observed in these cartridges.
Mean ± standard deviation metal concentrations in ENDS brands from liquid (µg/g) and aerosol (ng/10 puffs).
| Brand | Matrix | Units | Cu | Zn |
|---|---|---|---|---|
|
| Liquid | µg/g | 125 ± 12 | 30.2 ± 9.0 |
| Aerosol 1 year old | ng/10 puffs | 488 * | 265 ± 111 | |
|
| Liquid 1 year old | µg/g | 614 ± 64 | 339 ± 90 |
| Aerosol 2 years old | ng/10 puffs | 251 ± 29 | 111 ± 9 |
* Duplicate results.