Literature DB >> 31764350

Partially Melted Ti6Al4V Particles Increase Bacterial Adhesion and Inhibit Osteogenic Activity on 3D-printed Implants: An In Vitro Study.

Kai Xie1, Yu Guo, Shuang Zhao, Lei Wang, Junxiang Wu, Jia Tan, Yangzi Yang, Wen Wu, Wenbo Jiang, Yongqiang Hao.   

Abstract

BACKGROUND: A porous Ti6Al4V implant that is manufactured using selective laser melting (SLM) has broad potential applications in the field of orthopaedic implants. The pore structure of the SLM porous Ti6Al4V implant allows for cell migration and osteogenic differentiation, which is favorable for bone ingrowth and osseointegration. However, it is unclear whether the pore structure and partially melted Ti6Al4V particles on a SLM porous Ti6Al4V implant will increase bacterial adhesion and, perhaps, the risk of implant-related infection. QUESTIONS/PURPOSES: (1) Is there more bacterial adhesion and colonization on SLM porous Ti6Al4V implants than on polished orthopaedic implants? (2) Do partially melted Ti6Al4V particles on SLM porous Ti6Al4V implants reduce human bone mesenchymal stem cells (hBMSCs) adhesion, viability, and activity?
METHODS: To determine bacterial adhesion and biofilm formation, we incubated five different Ti6Al4V discs (polished, grit-blasted, plasma-sprayed, particle SLM porous, and nonparticle SLM porous discs) with methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli. Bacterial coverage on the surface of the five different Ti6Al4V discs were evaluated based on scanning electron microscopy (SEM) images quantitatively. In addition, a spread-plate method was used to quantitatively evaluate the bacterial adhesion on those implants. The biofilm formation was stained with crystal violet and semi-quantitatively determined with a microplate reader. The morphology and adhesion of hBMSCs on the five Ti6Al4V discs were observed with SEM. The cell viability was quantitatively evaluated with a Cell Counting Kit-8 assay. In addition, the osteogenic activity was determined in vitro with a quantitatively alkaline phosphatase activity assay and alizarin-red staining. For semiquantitative analysis, the alizarin-red stained mineralized nodules were dissolved and determined with a microplate reader.
RESULTS: The polished discs had the lowest MRSA adhesion (8.3% ± 2.6%) compared with grit-blasted (19.1% ± 3.9%; p = 0.006), plasma-sprayed (38.5% ± 5.3%; p < 0.001), particle (23.1% ± 2.8%; p < 0.001), and nonparticle discs (15.7% ± 2.5%; p = 0.003). Additionally, when comparing the two SLM discs, we found that particle discs had higher bacterial coverage than nonparticle discs (23.1% ± 2.8% versus 15.7% ± 2.5%; p = 0.020). An E. coli analysis showed similar results, with the higher adhesion to particle SLM discs than to nonparticle discs (20.7% ± 4.2% versus 14.4% ± 3.6%; p = 0.011). In addition, on particle SLM porous discs, bacterial colonies were localized around the partially melted Ti6Al4V particles, based on SEM images. After a 7-day incubation period, the cell viability in the particle group (optical density value 0.72 ± 0.05) was lower than that in the nonparticle groups (optical density value: 0.87 ± 0.08; p = 0.003). Alkaline phosphatase activity, as a marker of osteogenic differentiation, was lower in the particle group than in the nonparticle group (1.32 ± 0.12 U/mL versus 1.58 ± 0.09 U/mL; p = 0.012).
CONCLUSION: Higher bacterial adhesion was observed on SLM porous discs than on polished discs. The partially melted Ti6Al4V particles on SLM porous discs not only enhanced bacterial adhesion but also inhibited the osteogenic activity of hBMSCs. Postprocessing treatment is necessary to remove partially melted Ti6Al4V particles on an SLM implant before further use. Additional studies are needed to determine whether an SLM porous Ti6Al4V implant increases the risk of implant-related infection in vivo. CLINICAL RELEVANCE: As implants with porous Ti6Al4V made using SLM are being designed, our preliminary findings suggest that postprocessing treatment is needed to remove partially melted Ti6Al4V particles before further use. In addition, the depth of the porous structure of the SLM implant should not exceed the maximum depth of bone ingrowth because the host immune defense cannot prevent bacterial adhesion without integration.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31764350      PMCID: PMC6907305          DOI: 10.1097/CORR.0000000000000954

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  34 in total

1.  The effect of dental restorative materials on dental biofilm.

Authors:  Thorsten Mathias Auschill; Nicole Birgit Arweiler; Michel Brecx; Elmar Reich; Anton Sculean; Lutz Netuschil
Journal:  Eur J Oral Sci       Date:  2002-02       Impact factor: 2.612

Review 2.  Biofilm formation on dental restorative and implant materials.

Authors:  H J Busscher; M Rinastiti; W Siswomihardjo; H C van der Mei
Journal:  J Dent Res       Date:  2010-05-06       Impact factor: 6.116

3.  Ti-6Al-4V triply periodic minimal surface structures for bone implants fabricated via selective laser melting.

Authors:  Chunze Yan; Liang Hao; Ahmed Hussein; Philippe Young
Journal:  J Mech Behav Biomed Mater       Date:  2015-07-09

4.  Osseointegration of three-dimensional designed titanium implants manufactured by selective laser melting.

Authors:  Algabri Shaoki; Jia-Yun Xu; Haipeng Sun; Xian-Shuai Chen; Jianglin Ouyang; Xiu-Mei Zhuang; Fei-Long Deng
Journal:  Biofabrication       Date:  2016-10-27       Impact factor: 9.954

5.  Long-Term Prevention of Bacterial Infection and Enhanced Osteoinductivity of a Hybrid Coating with Selective Silver Toxicity.

Authors:  Kai Xie; Ziao Zhou; Yu Guo; Lei Wang; Guoyuan Li; Shuang Zhao; Xiangmei Liu; Jun Li; Wenbo Jiang; Shuilin Wu; Yongqiang Hao
Journal:  Adv Healthc Mater       Date:  2019-01-23       Impact factor: 9.933

6.  Engineering of Micro- to Nanostructured 3D-Printed Drug-Releasing Titanium Implants for Enhanced Osseointegration and Localized Delivery of Anticancer Drugs.

Authors:  Shaheer Maher; Gagandeep Kaur; Luis Lima-Marques; Andreas Evdokiou; Dusan Losic
Journal:  ACS Appl Mater Interfaces       Date:  2017-08-24       Impact factor: 9.229

Review 7.  Metallic powder-bed based 3D printing of cellular scaffolds for orthopaedic implants: A state-of-the-art review on manufacturing, topological design, mechanical properties and biocompatibility.

Authors:  X P Tan; Y J Tan; C S L Chow; S B Tor; W Y Yeong
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2017-02-24       Impact factor: 7.328

8.  Promising characteristics of gradient porosity Ti-6Al-4V alloy prepared by SLM process.

Authors:  Michaela Fousová; Dalibor Vojtěch; Jiří Kubásek; Eva Jablonská; Jaroslav Fojt
Journal:  J Mech Behav Biomed Mater       Date:  2017-01-31

9.  Rate and Risk Factors for Periprosthetic Joint Infection Among 36,494 Primary Total Hip Arthroplasties.

Authors:  Georgios K Triantafyllopoulos; Vasileios G Soranoglou; Stavros G Memtsoudis; Thomas P Sculco; Lazaros A Poultsides
Journal:  J Arthroplasty       Date:  2017-11-29       Impact factor: 4.757

10.  Tobacco Use and Risk of Wound Complications and Periprosthetic Joint Infection: A Systematic Review and Meta-Analysis of Primary Total Joint Arthroplasty Procedures.

Authors:  Nicholas A Bedard; David E DeMik; Jessell M Owens; Natalie A Glass; Jennifer DeBerg; John J Callaghan
Journal:  J Arthroplasty       Date:  2018-10-09       Impact factor: 4.757

View more
  7 in total

1.  CORR Insights®: Partially Melted Ti6Al4V Particles Increase Bacterial Adhesion and Inhibit Osteogenic Activity on 3D-printed Implants: An In Vitro Study.

Authors:  Jonathan P Garino
Journal:  Clin Orthop Relat Res       Date:  2019-12       Impact factor: 4.176

2.  Three-dimensional-printed titanium prostheses with bone trabeculae enable mechanical-biological reconstruction after resection of bone tumours.

Authors:  Feifei Pu; Wei Wu; Doudou Jing; Yihan Yu; Yizhong Peng; Jianxiang Liu; Qiang Wu; Baichuan Wang; Zhicai Zhang; Zengwu Shao
Journal:  Biomater Transl       Date:  2022-06-28

3.  A prospective study on outcome of patient-specific cones in revision knee arthroplasty.

Authors:  Alexander A Cherny; Anton N Kovalenko; Taras A Kulyaba; Nikolai N Kornilov
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-15       Impact factor: 3.067

4.  A Novel Strategy to Coat Dopamine-Functionalized Titanium Surfaces With Agarose-Based Hydrogels for the Controlled Release of Gentamicin.

Authors:  H Melis Soylu; Pascale Chevallier; Francesco Copes; Federica Ponti; Gabriele Candiani; Fatma Yurt; Diego Mantovani
Journal:  Front Cell Infect Microbiol       Date:  2021-06-10       Impact factor: 5.293

5.  Characterization of dimensional, morphological and morphometric features of retrieved 3D-printed acetabular cups for hip arthroplasty.

Authors:  Lorenzo Dall'Ava; Harry Hothi; Johann Henckel; Anna Di Laura; Paul Shearing; Alister Hart
Journal:  J Orthop Surg Res       Date:  2020-04-19       Impact factor: 2.359

6.  Susceptibility to biofilm formation on 3D-printed titanium fixation plates used in the mandible: a preliminary study.

Authors:  Lukasz Palka; Justyna Mazurek-Popczyk; Katarzyna Arkusz; Katarzyna Baldy-Chudzik
Journal:  J Oral Microbiol       Date:  2020-10-29       Impact factor: 5.474

7.  Mediation of mechanically adapted TiCu/TiCuN/CFR-PEEK implants in vascular regeneration to promote bone repair in vitro and in vivo.

Authors:  Yu Guo; Chenglong Chen; Shuyuan Zhang; Ling Ren; Yanhui Zhao; Wei Guo
Journal:  J Orthop Translat       Date:  2022-03-08       Impact factor: 5.191

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.