The particulate matter (PM) could be simultaneously removed during the wet flue gas desulfurization (WFGD) process. To analyze the underlying mechanism and removal efficiency, the PM removal process in a desulfurization system was numerically simulated based on the population balance model and general dynamics equation in this study. The equation was solved using the fixed-step Monte Carlo method to determine the PM removal characteristics under different working conditions (such as spray intensity, velocity of the flue gas, and layers of slurry spray). When the flue gas velocity decreased from 7 to 3 m/s, the removal efficiency increased from 90.93 to 93.52%, and when the mean geometric droplet size decreased from 3 to 1 mm, the removal efficiency increased from 67.18 to 99.14%. Besides, large diameter PM was more easily removed by the desulfurization system. Thus, the numerical simulation method was proven to be feasible by comparing these results with field measurements of a WFGD system in a coal-fired power plant.Keywords: Coal-fired power plant; Numerical simulation; PMs; Simultaneous removal
Mesh:
Substances:
Year: 2019 PMID: 31755062 DOI: 10.1007/s11356-019-06773-9
Source DB: PubMed Journal: Environ Sci Pollut Res Int ISSN: 0944-1344 Impact factor: 4.223