Monte Carlo dosimetric study of best industries and Alpha Omega Ir-192 brachytherapy seeds.

F Ballester1, D Granero, J Pérez-Calatayud, E Casal, V Puchades.   

Abstract

Ir-192 seeds are widely used in the USA for low dose rate interstitial brachytherapy. There are two commercially available models: those manufactured by Best Industries filtered with stainless steel, and those manufactured by Alpha-Omega seeds filtered with Pt. Newly developed 3D correction algorithms for brachytherapy are based on dosimetry data obtained on unbounded phantom size, allowing corrections for heterogeneities and actual tissue boundaries. Published dosimetric datasets for both seeds have been obtained under bounded conditions. The aim of the present study is to obtain dosimetric datasets for these seeds under full scatter conditions. The Monte Carlo GEANT4 code has been used to estimate air-kerma strength and dose rate in water around the Ir-192 seeds. Functions and parameters following the TG43 formalism are obtained and presented in tabular forms: the dose rate constant, the radial dose function, and the anisotropy function. Tables for the anisotropy factor have been obtained in order to apply punctual approximation. Differences between dose rate distributions for both seeds show that specific dataset must be used for each type of seed in clinical dosimetry. The data in the present study improve on published data in the following aspects: (i) dosimetric data were obtained under full scatter conditions, which affect dose values at distances greater than 4-5 cm from the source; (ii) the dose rate tables are given at greater distances from the source; and (iii) the spatial resolution in high dose gradient areas, such as those near the longitudinal source axis, has been improved.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15651612     DOI: 10.1118/1.1820013

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Dosimetric characteristics of the ¹⁹²Ir high-dose-rate afterloading brachytherapy source.

Authors:  Mahdi Sadeghi; Fatemah Taghdiri; Pooneh Saidi
Journal:  Jpn J Radiol       Date:  2011-06-30       Impact factor: 2.374

2.  Numerical simulation of the simultaneous removal of particulate matter in a wet flue gas desulfurization system.

Authors:  Yueqi Huang; Chenghang Zheng; Qingyi Li; Jun Zhang; Yishan Guo; Yongxin Zhang; Xiang Gao
Journal:  Environ Sci Pollut Res Int       Date:  2019-11-21       Impact factor: 4.223

3.  HDR brachytherapy in vivo source position verification using a 2D diode array: A Monte Carlo study.

Authors:  Joel Poder; Dean Cutajar; Susanna Guatelli; Marco Petasecca; Andrew Howie; Joseph Bucci; Anatoly Rosenfeld
Journal:  J Appl Clin Med Phys       Date:  2018-06-01       Impact factor: 2.102

4.  BEBIG 60Co HDR brachytherapy source dosimetric parameters validation using GATE Geant4-based simulation code.

Authors:  Musa Joya; Hassan Ali Nedaie; Ghazale Geraily; Mahdi Ghorbani; Peyman Sheikhzadeh; Mahmud Naraqi Arani
Journal:  Heliyon       Date:  2022-03-27

5.  Gafchromic film dosimetry of a new HDR 192Ir brachytherapy source.

Authors:  Navid Ayoobian; Akbar Sarabi Asl; Hosein Poorbaygi; Mohammad Reza Javanshir
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.